Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles

Background:Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a ca...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schaefer, Tabea (VerfasserIn) , Greive, Svenja (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Kramer, Martin (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Vollherbst, Dominik (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Journal of endovascular therapy
Year: 2022, Jahrgang: 00, Pages: 1-10
ISSN:1545-1550
DOI:10.1177/15266028221082010
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1177/15266028221082010
Verlag, kostenfrei, Volltext: https://journals.sagepub.com/doi/10.1177/15266028221082010
Volltext
Verfasserangaben:Tabea C. Schaefer, Svenja Greive, Sabine Heiland, Martin Kramer, Martin Bendszus, and Dominik F. Vollherbst

MARC

LEADER 00000caa a2200000 c 4500
001 1839715111
003 DE-627
005 20230706230142.0
007 cr uuu---uuuuu
008 230321s2022 xx |||||o 00| ||eng c
024 7 |a 10.1177/15266028221082010  |2 doi 
035 |a (DE-627)1839715111 
035 |a (DE-599)KXP1839715111 
035 |a (OCoLC)1389534282 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schaefer, Tabea  |e VerfasserIn  |0 (DE-588)1284016234  |0 (DE-627)1839714697  |4 aut 
245 1 0 |a Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles  |c Tabea C. Schaefer, Svenja Greive, Sabine Heiland, Martin Kramer, Martin Bendszus, and Dominik F. Vollherbst 
264 1 |c 2022 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.03.2023 
520 |a Background:Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a catheter on these MAB, and to demonstrate the applicability of this model in vivo.Materials and Methods:Micro air bubbles were created using a system based on microfluidic channels. The MAB were detected and analyzed automatically. Micro air bubbles, with a target size of 85 µm, were generated and injected through a microcatheter. The MAB diameters proximal and distal to the catheter were assessed and compared. In a subsequent in vivo application, 2000 MAB were injected into the aorta (at the aortic valve) and into the common carotid artery (CCA) of a rat, respectively, using a microcatheter, resembling AE occurring during cardiovascular interventions.Results:Micro air bubbles with a highly calibrated size could be successfully generated (median: 85.5 µm, SD 1.9 µm). After passage of the microcatheter, the MAB were similar in diameter (median: 86.6 µm) but at a lower number (60.1% of the injected MAB) and a substantially higher scattering of diameters (SD 29.6 µm). In vivo injection of MAB into the aorta resulted in cerebral microinfarctions in both hemispheres, whereas injection into the CCA caused exclusively ipsilateral microinfarctions.Conclusion:Using this new AE model, MAB can be generated precisely and reproducibly, resulting in cerebral microinfarctions. This model is feasible for further studies on the pathophysiology and prevention of AE in cardiovascular procedures. 
700 1 |a Greive, Svenja  |d 1998-  |e VerfasserIn  |0 (DE-588)1284016439  |0 (DE-627)1839714875  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Kramer, Martin  |d 1961-  |e VerfasserIn  |0 (DE-588)133238512  |0 (DE-627)691269548  |0 (DE-576)299716929  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Vollherbst, Dominik  |d 1989-  |e VerfasserIn  |0 (DE-588)1071379569  |0 (DE-627)825819024  |0 (DE-576)407878866  |4 aut 
773 0 8 |i Enthalten in  |t Journal of endovascular therapy  |d Thousand Oaks, Calif. : Sage, 2000  |g 00(2022), 0, Artikel-ID 15266028221082010, Seite 1-10  |h Online-Ressource  |w (DE-627)330217410  |w (DE-600)2049858-5  |w (DE-576)34699313X  |x 1545-1550  |7 nnas  |a Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles 
773 1 8 |g volume:00  |g year:2022  |g number:0  |g elocationid:15266028221082010  |g pages:1-10  |g extent:10  |a Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles 
856 4 0 |u https://doi.org/10.1177/15266028221082010  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://journals.sagepub.com/doi/10.1177/15266028221082010  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230321 
993 |a Article 
994 |a 2022 
998 |g 1071379569  |a Vollherbst, Dominik  |m 1071379569:Vollherbst, Dominik  |d 910000  |d 911100  |d 50000  |e 910000PV1071379569  |e 911100PV1071379569  |e 50000PV1071379569  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 6  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 5 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1284016439  |a Greive, Svenja  |m 1284016439:Greive, Svenja  |d 50000  |e 50000PG1284016439  |k 0/50000/  |p 2 
998 |g 1284016234  |a Schaefer, Tabea  |m 1284016234:Schaefer, Tabea  |d 910000  |d 911100  |e 910000PS1284016234  |e 911100PS1284016234  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1839715111  |e 4294363843 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["Tabea C. Schaefer, Svenja Greive, Sabine Heiland, Martin Kramer, Martin Bendszus, and Dominik F. Vollherbst"]},"language":["eng"],"recId":"1839715111","id":{"doi":["10.1177/15266028221082010"],"eki":["1839715111"]},"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"2022"}],"note":["Gesehen am 21.03.2023"],"physDesc":[{"extent":"10 S."}],"title":[{"title":"Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles","title_sort":"Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles"}],"person":[{"role":"aut","display":"Schaefer, Tabea","given":"Tabea","family":"Schaefer"},{"family":"Greive","given":"Svenja","role":"aut","display":"Greive, Svenja"},{"given":"Sabine","family":"Heiland","display":"Heiland, Sabine","role":"aut"},{"display":"Kramer, Martin","role":"aut","given":"Martin","family":"Kramer"},{"family":"Bendszus","given":"Martin","display":"Bendszus, Martin","role":"aut"},{"display":"Vollherbst, Dominik","role":"aut","given":"Dominik","family":"Vollherbst"}],"relHost":[{"title":[{"title_sort":"Journal of endovascular therapy","title":"Journal of endovascular therapy","subtitle":"an official publication of the International Society of Endovascular Specialists"}],"part":{"issue":"0","pages":"1-10","text":"00(2022), 0, Artikel-ID 15266028221082010, Seite 1-10","extent":"10","volume":"00","year":"2022"},"corporate":[{"role":"isb","display":"International Society of Endovascular Specialists"}],"language":["eng"],"disp":"Investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubblesJournal of endovascular therapy","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 30.09.22"],"origin":[{"dateIssuedDisp":"2000-","publisher":"Sage ; International Society of Endovascular Specialists","dateIssuedKey":"2000","publisherPlace":"Thousand Oaks, Calif. ; Phoenix, Ariz."}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"330217410","pubHistory":["Volume 7, no. 1 (February 2000)-"],"id":{"zdb":["2049858-5"],"issn":["1545-1550"],"eki":["330217410"]}}]} 
SRT |a SCHAEFERTAINVESTIGAT2022