Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography

To quantitatively estimate lumen narrowing and to assess the volume and composition of atherosclerotic plaque with 256-slice computed tomography angiography (CTA), using conventional quantitative coronary angiography (QCA) as the gold standard.

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Korosoglou, Grigorios (VerfasserIn) , Mueller, Dirk (VerfasserIn) , Lehrke, Stephanie (VerfasserIn) , Steen, Henning (VerfasserIn) , Hosch, Waldemar P. (VerfasserIn) , Heye, Tobias (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Giannitsis, Evangelos (VerfasserIn) , Katus, Hugo (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 20 March 2010
In: European radiology
Year: 2010, Jahrgang: 20, Heft: 8, Pages: 1841-1850
ISSN:1432-1084
DOI:10.1007/s00330-010-1753-3
Online-Zugang:Resolving-System, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00330-010-1753-3
Verlag, lizenzpflichtig, Volltext: https://link.springer.com/article/10.1007/s00330-010-1753-3
Volltext
Verfasserangaben:Grigorios Korosoglou, Dirk Mueller, Stephanie Lehrke, Henning Steen, Waldemar Hosch, Tobias Heye, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus

MARC

LEADER 00000caa a2200000 c 4500
001 1839760362
003 DE-627
005 20230710145621.0
007 cr uuu---uuuuu
008 230322s2010 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-010-1753-3  |2 doi 
035 |a (DE-627)1839760362 
035 |a (DE-599)KXP1839760362 
035 |a (OCoLC)1389807180 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Korosoglou, Grigorios  |d 1976-  |e VerfasserIn  |0 (DE-588)12854225X  |0 (DE-627)374709025  |0 (DE-576)297204912  |4 aut 
245 1 0 |a Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography  |c Grigorios Korosoglou, Dirk Mueller, Stephanie Lehrke, Henning Steen, Waldemar Hosch, Tobias Heye, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus 
264 1 |c 20 March 2010 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 22.03.2023 
520 |a To quantitatively estimate lumen narrowing and to assess the volume and composition of atherosclerotic plaque with 256-slice computed tomography angiography (CTA), using conventional quantitative coronary angiography (QCA) as the gold standard. 
650 4 |a Atherosclerotic plaque 
650 4 |a Cardiac computed tomography 
650 4 |a Coronary lumen narrowing 
650 4 |a Quantitative coronary angiography 
700 1 |a Mueller, Dirk  |e VerfasserIn  |4 aut 
700 1 |a Lehrke, Stephanie  |d 1976-  |e VerfasserIn  |0 (DE-588)123769175  |0 (DE-627)706420756  |0 (DE-576)29387008X  |4 aut 
700 1 |a Steen, Henning  |d 1972-  |e VerfasserIn  |0 (DE-588)123681669  |0 (DE-627)706393600  |0 (DE-576)293824851  |4 aut 
700 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
700 1 |a Heye, Tobias  |d 1976-  |e VerfasserIn  |0 (DE-588)133300943  |0 (DE-627)691326002  |0 (DE-576)271430303  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Giannitsis, Evangelos  |e VerfasserIn  |0 (DE-588)113336241  |0 (DE-627)577184091  |0 (DE-576)289759579  |4 aut 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 20(2010), 8, Seite 1841-1850  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography 
773 1 8 |g volume:20  |g year:2010  |g number:8  |g pages:1841-1850  |g extent:10  |a Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography 
856 4 0 |u https://doi.org/10.1007/s00330-010-1753-3  |x Resolving-System  |x Verlag  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s00330-010-1753-3  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230322 
993 |a Article 
994 |a 2010 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 9  |y j 
998 |g 113336241  |a Giannitsis, Evangelos  |m 113336241:Giannitsis, Evangelos  |d 910000  |d 910100  |d 50000  |e 910000PG113336241  |e 910100PG113336241  |e 50000PG113336241  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 133300943  |a Heye, Tobias  |m 133300943:Heye, Tobias  |d 910000  |d 911400  |e 910000PH133300943  |e 911400PH133300943  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 50000  |e 50000PH11585696X  |k 0/50000/  |p 5 
998 |g 123681669  |a Steen, Henning  |m 123681669:Steen, Henning  |d 910000  |d 910100  |e 910000PS123681669  |e 910100PS123681669  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 123769175  |a Lehrke, Stephanie  |m 123769175:Lehrke, Stephanie  |d 910000  |d 910100  |e 910000PL123769175  |e 910100PL123769175  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 12854225X  |a Korosoglou, Grigorios  |m 12854225X:Korosoglou, Grigorios  |d 910000  |d 910100  |e 910000PK12854225X  |e 910100PK12854225X  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1839760362  |e 4294525207 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["Grigorios Korosoglou, Dirk Mueller, Stephanie Lehrke, Henning Steen, Waldemar Hosch, Tobias Heye, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus"]},"language":["eng"],"id":{"doi":["10.1007/s00330-010-1753-3"],"eki":["1839760362"]},"physDesc":[{"extent":"10 S."}],"title":[{"title":"Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography","title_sort":"Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography"}],"person":[{"role":"aut","display":"Korosoglou, Grigorios","given":"Grigorios","family":"Korosoglou"},{"family":"Mueller","display":"Mueller, Dirk","given":"Dirk","role":"aut"},{"family":"Lehrke","display":"Lehrke, Stephanie","given":"Stephanie","role":"aut"},{"family":"Steen","role":"aut","display":"Steen, Henning","given":"Henning"},{"role":"aut","display":"Hosch, Waldemar P.","given":"Waldemar P.","family":"Hosch"},{"family":"Heye","role":"aut","given":"Tobias","display":"Heye, Tobias"},{"family":"Kauczor","role":"aut","given":"Hans-Ulrich","display":"Kauczor, Hans-Ulrich"},{"role":"aut","display":"Giannitsis, Evangelos","given":"Evangelos","family":"Giannitsis"},{"role":"aut","display":"Katus, Hugo","given":"Hugo","family":"Katus"}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"20 March 2010"}],"note":["Gesehen am 22.03.2023"],"relHost":[{"corporate":[{"display":"European Association of Radiology","role":"isb"}],"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"European radiology","subtitle":"official organ of the European Association of Radiology","title":"European radiology"}],"part":{"pages":"1841-1850","year":"2010","text":"20(2010), 8, Seite 1841-1850","extent":"10","volume":"20","issue":"8"},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomographyEuropean radiology","origin":[{"publisherPlace":"Berlin ; Heidelberg","publisher":"Springer","dateIssuedDisp":"1991-","dateIssuedKey":"1991"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"pubHistory":["1.1991 -"],"recId":"268757526","language":["eng"],"id":{"zdb":["1472718-3"],"eki":["268757526"],"issn":["1432-1084","1613-3757"]}}],"recId":"1839760362"} 
SRT |a KOROSOGLOUQUANTITATI2020