Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation

Background - Deviations from nominal alignment of unicondylar knee replacements impact knee biomechanics, including the load and stress distribution at the articular contact surfaces. This study characterizes relationships between the biomechanical environment, distinguished by progressive changes i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Harman, Melinda K. (VerfasserIn) , Schmitt, Sabine (VerfasserIn) , Rössing, Sven (VerfasserIn) , Banks, Scott A. (VerfasserIn) , Scharf, Hanns-Peter (VerfasserIn) , Viceconti, Marco (VerfasserIn) , Hodge, W. Andrew (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [July 2010]
In: Clinical biomechanics
Year: 2010, Jahrgang: 25, Heft: 6, Pages: 570-575
ISSN:1879-1271
DOI:10.1016/j.clinbiomech.2010.03.013
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.clinbiomech.2010.03.013
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0268003310000987
Volltext
Verfasserangaben:Melinda K. Harman, Sabine Schmitt, Sven Rössing, Scott A. Banks, Hans-Peter Sharf, Marco Viceconti, W. Andrew Hodge

MARC

LEADER 00000caa a2200000 c 4500
001 1839999535
003 DE-627
005 20230710145246.0
007 cr uuu---uuuuu
008 230324s2010 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.clinbiomech.2010.03.013  |2 doi 
035 |a (DE-627)1839999535 
035 |a (DE-599)KXP1839999535 
035 |a (OCoLC)1389806575 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Harman, Melinda K.  |e VerfasserIn  |0 (DE-588)1281765996  |0 (DE-627)1837629609  |4 aut 
245 1 0 |a Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation  |c Melinda K. Harman, Sabine Schmitt, Sven Rössing, Scott A. Banks, Hans-Peter Sharf, Marco Viceconti, W. Andrew Hodge 
264 1 |c [July 2010] 
300 |b Illustrationen 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.03.2023 
520 |a Background - Deviations from nominal alignment of unicondylar knee replacements impact knee biomechanics, including the load and stress distribution at the articular contact surfaces. This study characterizes relationships between the biomechanical environment, distinguished by progressive changes in alignment and fixation, and articular damage and deformation in a consecutive series of retrieved unicondylar knee replacements. - Methods - Twenty seven fixed-bearing, non-conforming unicondylar knee replacements of one design were retrieved after 2 to 13years of in vivo function. The in vivo biomechanical environment was characterized by grading component migration measured from full-length radiographs and grading component fixation based on intraoperative manual palpation. Articular damage patterns and linear deformation on the polyethylene inserts were measured using optical photogrammetry and contact point digitization. - Findings - Articular damage patterns and surface deformation on the explanted polyethylene inserts corresponded to progressive changes in component alignment and fixation. Component migration produced higher deformation rates, whereas loosening contributed to larger damage areas but lower deformation rates. Migration and loosening of the femoral component, but not the tibial component, were factors contributing to large regions of abrasion concentrated on the articular periphery. - Interpretation - Classifying component migration and fixation at revision proved useful for distinguishing common biomechanical conditions associated with the varied polyethylene damage patterns and linear deformation for this fixed-bearing, non-conforming design. Pre-clinical evaluations of unicondylar knee replacements that are capable of reproducing variations in clinical alignment and predicting the observed wear mechanisms are necessary to better understand the impact of knee biomechanics and design on unicondylar knee replacement longevity. 
650 4 |a Biomechanics 
650 4 |a Implants 
650 4 |a Knee replacement 
650 4 |a Materials 
650 4 |a Modeling 
650 4 |a Stress 
650 4 |a Tribology 
700 1 |a Schmitt, Sabine  |e VerfasserIn  |4 aut 
700 1 |a Rössing, Sven  |d 1972-  |e VerfasserIn  |0 (DE-588)123903904  |0 (DE-627)70646818X  |0 (DE-576)293935688  |4 aut 
700 1 |a Banks, Scott A.  |e VerfasserIn  |4 aut 
700 1 |a Scharf, Hanns-Peter  |d 1953-  |e VerfasserIn  |0 (DE-588)109675266  |0 (DE-627)587792329  |0 (DE-576)168550776  |4 aut 
700 1 |a Viceconti, Marco  |e VerfasserIn  |4 aut 
700 1 |a Hodge, W. Andrew  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Clinical biomechanics  |d Amsterdam [u.a.] : Elsevier Science, 1986  |g 25(2010), 6 vom: Juli, Seite 570-575  |h Online-Ressource  |w (DE-627)32043740X  |w (DE-600)2004518-9  |w (DE-576)261823612  |x 1879-1271  |7 nnas  |a Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation 
773 1 8 |g volume:25  |g year:2010  |g number:6  |g month:07  |g pages:570-575  |g extent:6  |a Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation 
856 4 0 |u https://doi.org/10.1016/j.clinbiomech.2010.03.013  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0268003310000987  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230324 
993 |a Article 
994 |a 2010 
998 |g 109675266  |a Scharf, Hanns-Peter  |m 109675266:Scharf, Hanns-Peter  |d 60000  |d 62400  |e 60000PS109675266  |e 62400PS109675266  |k 0/60000/  |k 1/60000/62400/  |p 5 
998 |g 123903904  |a Rössing, Sven  |m 123903904:Rössing, Sven  |d 60000  |d 62400  |e 60000PR123903904  |e 62400PR123903904  |k 0/60000/  |k 1/60000/62400/  |p 3 
999 |a KXP-PPN1839999535  |e 4296581597 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1016/j.clinbiomech.2010.03.013"],"eki":["1839999535"]},"name":{"displayForm":["Melinda K. Harman, Sabine Schmitt, Sven Rössing, Scott A. Banks, Hans-Peter Sharf, Marco Viceconti, W. Andrew Hodge"]},"note":["Gesehen am 24.03.2023"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"title_sort":"Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation","title":"Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation"}],"person":[{"family":"Harman","role":"aut","given":"Melinda K.","display":"Harman, Melinda K."},{"display":"Schmitt, Sabine","family":"Schmitt","given":"Sabine","role":"aut"},{"display":"Rössing, Sven","family":"Rössing","given":"Sven","role":"aut"},{"display":"Banks, Scott A.","given":"Scott A.","role":"aut","family":"Banks"},{"display":"Scharf, Hanns-Peter","role":"aut","given":"Hanns-Peter","family":"Scharf"},{"family":"Viceconti","role":"aut","given":"Marco","display":"Viceconti, Marco"},{"display":"Hodge, W. Andrew","family":"Hodge","role":"aut","given":"W. Andrew"}],"relHost":[{"id":{"eki":["32043740X"],"issn":["1879-1271"],"zdb":["2004518-9"]},"title":[{"subtitle":"a journal affiliated to the International Society of Biomechanics and the American Society of Biomechanics","title":"Clinical biomechanics","title_sort":"Clinical biomechanics"}],"part":{"issue":"6","text":"25(2010), 6 vom: Juli, Seite 570-575","extent":"6","pages":"570-575","volume":"25","year":"2010"},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 04.02.20"],"origin":[{"dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science"}],"pubHistory":["1.1986 -"],"disp":"Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixationClinical biomechanics","recId":"32043740X","physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedDisp":"[July 2010]","dateIssuedKey":"2010"}],"physDesc":[{"extent":"6 S.","noteIll":"Illustrationen"}],"recId":"1839999535"} 
SRT |a HARMANMELIPOLYETHYLE2010