Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens
Purpose - Evaluation of reading performance with a novel presbyopia correcting intraocular lens (IOL) in refractive lens exchange using an electronic reading desk. - Design - Prospective interventional before-and-after clinical study. - Methods - In total, 56 eyes of 28 patients were included. Bilat...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
28 February 2023
|
| In: |
American journal of ophthalmology
Year: 2023, Volume: 250, Pages: 25-37 |
| ISSN: | 1879-1891 |
| DOI: | 10.1016/j.ajo.2023.01.011 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ajo.2023.01.011 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0002939423000211 |
| Author Notes: | Isabella D. Baur, Gerd U. Auffarth, Grzegorz Łabuz, Annette Stengele, Mustafa K. Hallak, and Ramin Khoramnia |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1840069244 | ||
| 003 | DE-627 | ||
| 005 | 20230706215116.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230324s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ajo.2023.01.011 |2 doi | |
| 035 | |a (DE-627)1840069244 | ||
| 035 | |a (DE-599)KXP1840069244 | ||
| 035 | |a (OCoLC)1389530950 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Baur, Isabella |e VerfasserIn |0 (DE-588)1196639396 |0 (DE-627)1678468975 |4 aut | |
| 245 | 1 | 0 | |a Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens |c Isabella D. Baur, Gerd U. Auffarth, Grzegorz Łabuz, Annette Stengele, Mustafa K. Hallak, and Ramin Khoramnia |
| 264 | 1 | |c 28 February 2023 | |
| 300 | |a 13 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online verfügbar 18 Januar 2023, Artikelversion 28 Februar 2023 | ||
| 500 | |a Gesehen am 24.03.2023 | ||
| 520 | |a Purpose - Evaluation of reading performance with a novel presbyopia correcting intraocular lens (IOL) in refractive lens exchange using an electronic reading desk. - Design - Prospective interventional before-and-after clinical study. - Methods - In total, 56 eyes of 28 patients were included. Bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Surgical Vision) during a bilateral delayed sequential refractive lens exchange procedure. Uncorrected and distance corrected reading acuity, reading distance, reading speed, and the smallest print size that could be read effectively at a set (40 cm/80 cm) and subjectively chosen near and intermediate distance were assessed using the Salzburg Reading Desk preoperatively and 6 months after surgery. - Results - Uncorrected near reading acuity increased from 0.61 ± 0.16 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.05 ± 0.09 logMAR postoperatively at the set near distance (40 cm) and from 0.60 ± 0.11 logMAR to 0.07 ± 0.08 logMAR at the subjectively preferred distance (39.6 ± 5.3 cm and 37.7 ± 4.3 cm). Uncorrected intermediate reading acuity was 0.39 ± 0.19 logMAR preoperatively and 0.08 ± 0.07 logMAR postoperatively at the set intermediate distance (80 cm) and 0.43 ± 0.21 logMAR preoperatively and 0.07 ± 0.08 logMAR postoperatively at the preferred intermediate distance (73.5 ± 9.5 cm and 73.3 ± 5.9 cm). - Conclusions - Uncorrected intermediate and near reading function considerably improved after bilateral implantation of the TECNIS Synergy IOL. Patients preferred a closer near and intermediate distance to the set distances. However, reading function was comparable for the set and subjectively preferred distances. | ||
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 700 | 1 | |a Łabuz, Grzegorz |e VerfasserIn |0 (DE-588)1185406743 |0 (DE-627)1664595244 |4 aut | |
| 700 | 1 | |a Stengele, Annette |e VerfasserIn |0 (DE-588)1284331350 |0 (DE-627)1840070021 |4 aut | |
| 700 | 1 | |a Hallak, Mustafa |e VerfasserIn |0 (DE-588)1284331733 |0 (DE-627)1840070617 |4 aut | |
| 700 | 1 | |a Khoramnia, Ramin |d 1980- |e VerfasserIn |0 (DE-588)132573954 |0 (DE-627)523957173 |0 (DE-576)299234355 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t American journal of ophthalmology |d New York, NY : Elsevier Science, 1918 |g 250(2023) vom: Feb., Seite 25-37 |h Online-Ressource |w (DE-627)320596281 |w (DE-600)2019600-3 |w (DE-576)121466353 |x 1879-1891 |7 nnas |a Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens |
| 773 | 1 | 8 | |g volume:250 |g year:2023 |g month:02 |g pages:25-37 |g extent:13 |a Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ajo.2023.01.011 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0002939423000211 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230324 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 132573954 |a Khoramnia, Ramin |m 132573954:Khoramnia, Ramin |d 910000 |d 910900 |d 50000 |e 910000PK132573954 |e 910900PK132573954 |e 50000PK132573954 |k 0/910000/ |k 1/910000/910900/ |k 0/50000/ |p 6 |y j | ||
| 998 | |g 1284331733 |a Hallak, Mustafa K. |m 1284331733:Hallak, Mustafa K. |d 910000 |d 910900 |e 910000PH1284331733 |e 910900PH1284331733 |k 0/910000/ |k 1/910000/910900/ |p 5 | ||
| 998 | |g 1284331350 |a Stengele, Annette |m 1284331350:Stengele, Annette |p 4 | ||
| 998 | |g 1185406743 |a Łabuz, Grzegorz |m 1185406743:Łabuz, Grzegorz |d 910000 |d 910900 |e 910000PŁ1185406743 |e 910900PŁ1185406743 |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 1196639396 |a Baur, Isabella |m 1196639396:Baur, Isabella |d 910000 |d 910900 |e 910000PB1196639396 |e 910900PB1196639396 |k 0/910000/ |k 1/910000/910900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1840069244 |e 4296817299 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"title_sort":"Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens","title":"Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens"}],"name":{"displayForm":["Isabella D. Baur, Gerd U. Auffarth, Grzegorz Łabuz, Annette Stengele, Mustafa K. Hallak, and Ramin Khoramnia"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1016/j.ajo.2023.01.011"],"eki":["1840069244"]},"person":[{"given":"Isabella","family":"Baur","role":"aut","display":"Baur, Isabella"},{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"given":"Grzegorz","role":"aut","display":"Łabuz, Grzegorz","family":"Łabuz"},{"given":"Annette","family":"Stengele","display":"Stengele, Annette","role":"aut"},{"given":"Mustafa","display":"Hallak, Mustafa","role":"aut","family":"Hallak"},{"given":"Ramin","family":"Khoramnia","role":"aut","display":"Khoramnia, Ramin"}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"28 February 2023"}],"language":["eng"],"note":["Online verfügbar 18 Januar 2023, Artikelversion 28 Februar 2023","Gesehen am 24.03.2023"],"recId":"1840069244","physDesc":[{"extent":"13 S."}],"relHost":[{"part":{"pages":"25-37","volume":"250","extent":"13","text":"250(2023) vom: Feb., Seite 25-37","year":"2023"},"id":{"zdb":["2019600-3"],"issn":["1879-1891"],"eki":["320596281"]},"origin":[{"dateIssuedDisp":"1918-","publisher":"Elsevier Science","dateIssuedKey":"1918","publisherPlace":"New York, NY"}],"name":{"displayForm":["Frank W. Newell, ed.-in-chief [u.a.]"]},"disp":"Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lensAmerican journal of ophthalmology","title":[{"subtitle":"AJO","title":"American journal of ophthalmology","title_sort":"American journal of ophthalmology"}],"language":["eng"],"pubHistory":["Nachgewiesen 3.Ser. 1.1918 -"],"titleAlt":[{"title":"AJO"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"320596281","note":["Gesehen am 21.09.2020","Ungezählte Beil.: Supplement"]}]} | ||
| SRT | |a BAURISABELCLINICALEV2820 | ||