Gas-chromatographic determination of nitrophenols after derivatisation with diazomethane

A method is described to determine nitrophenols and two herbicides (Bromoxynil, Ioxynil) in precipitation, with GC-PND and GC-MS. First, the micropollutants were extracted by a mixture of pentane and ether (1/1), concentrated by rotary evaporator, then methylated by diazomethane. The extraction and...

Full description

Saved in:
Bibliographic Details
Main Authors: Nick, Klaus (Author) , Schöler, Heinz Friedrich (Author)
Format: Article (Journal)
Language:English
Published: 1992
In: Fresenius' journal of analytical chemistry
Year: 1992, Volume: 343, Issue: 3, Pages: 304-307
ISSN:1432-1130
DOI:10.1007/BF00322379
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/BF00322379
Verlag, lizenzpflichtig, Volltext: http://link.springer.com/10.1007/BF00322379
Get full text
Author Notes:K. Nick, H.F. Schöler
Description
Summary:A method is described to determine nitrophenols and two herbicides (Bromoxynil, Ioxynil) in precipitation, with GC-PND and GC-MS. First, the micropollutants were extracted by a mixture of pentane and ether (1/1), concentrated by rotary evaporator, then methylated by diazomethane. The extraction and reaction yields were measured. The resulting recoveries were between 75 and 100% for the mononitrophenols and about 70% for methylnitrophenols. The detection limits were about 0.25 ~tg/1for most substances.