Determination of halogenated acetic acids and 2,2-dichloropropionic acid in water samples
A new method is described for the determination of halogenated acetic acids and 2,2-dichloropropionic acid in slightly polluted water. The acids were extracted in a light-phase rotary perforator, derivatised with diazomethane and determined by GC-ECD and GC-MS. The standard deviations were in the ra...
Gespeichert in:
| Hauptverfasser: | , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
1992
|
| In: |
Fresenius' journal of analytical chemistry
Year: 1992, Jahrgang: 344, Heft: 1, Pages: 47-49 |
| ISSN: | 1432-1130 |
| DOI: | 10.1007/BF00324841 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/BF00324841 |
| Verfasserangaben: | Markus Clemens, Heinz Friedrich Schöler |
| Zusammenfassung: | A new method is described for the determination of halogenated acetic acids and 2,2-dichloropropionic acid in slightly polluted water. The acids were extracted in a light-phase rotary perforator, derivatised with diazomethane and determined by GC-ECD and GC-MS. The standard deviations were in the range of 14.5-16.8%. Average recoveries were 82%, 92% and 79% for monochloro-, dichloro- and trichloroacetic acid, respectively. The extraction yields for the bromoacetic acids and dichloropropionic acid were in the range of 64-85%. |
|---|---|
| Beschreibung: | Gesehen am 04.04.2023 |
| Beschreibung: | Online Resource |
| ISSN: | 1432-1130 |
| DOI: | 10.1007/BF00324841 |