Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty: an in vitro study

Corrosion at the modular taper junctions in total hip arthroplasty is clinically relevant because wear particles and ions generated at this interface can lead to adverse local tissue reactions or even implant failure. In vitro tribo-corrosion tests are usually accomplished in saline solutions or cal...

Full description

Saved in:
Bibliographic Details
Main Authors: Bormann, Therese (Author) , Nebel, Laura (Author) , Müller, Ulrike (Author) , Mai, Phuong Thao (Author) , Gibmeier, Jens (Author) , Renkawitz, Tobias (Author) , Kretzer, Jan Philippe (Author)
Format: Article (Journal)
Language:English
Published: June 2022
In: Acta biomaterialia
Year: 2022, Volume: 145, Pages: 427-435
ISSN:1878-7568
DOI:10.1016/j.actbio.2022.04.007
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.actbio.2022.04.007
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1742706122002112
Get full text
Author Notes:Therese Bormann, Laura Nebel, Ulrike Müller, Phuong Thao Mai, Jens Gibmeier, Tobias Renkawitz, J. Philippe Kretzer

MARC

LEADER 00000caa a2200000 c 4500
001 1842707698
003 DE-627
005 20230706224751.0
007 cr uuu---uuuuu
008 230414s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.actbio.2022.04.007  |2 doi 
035 |a (DE-627)1842707698 
035 |a (DE-599)KXP1842707698 
035 |a (OCoLC)1389533935 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bormann, Therese  |e VerfasserIn  |0 (DE-588)1205894829  |0 (DE-627)1691740136  |4 aut 
245 1 0 |a Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty  |b an in vitro study  |c Therese Bormann, Laura Nebel, Ulrike Müller, Phuong Thao Mai, Jens Gibmeier, Tobias Renkawitz, J. Philippe Kretzer 
246 3 3 |a Influence of FeCl 3 and H 2 O 2 in corrosion testing of modular taper connections in total hip arthroplasty 
264 1 |c June 2022 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Im Titel sind die Zahlen 3 und 2 jeweils tiefgestellt 
500 |a Gesehen am 14.04.2022 
520 |a Corrosion at the modular taper junctions in total hip arthroplasty is clinically relevant because wear particles and ions generated at this interface can lead to adverse local tissue reactions or even implant failure. In vitro tribo-corrosion tests are usually accomplished in saline solutions or calf serum (CS), but the addition of H2O2 and FeCl3 have been suggested to mimic inflammatory conditions in the joint. Inflammatory conditions may aggravate corrosive processes and, therefore, should lead in vitro to a more severe and realistic tribo-corrosive material attack. Corrosion testing at 12/14 tapers comprising a CoCrMo head taper and a Ti6Al4V trunnion was accomplished in five electrolytes (Ringer's solution (RS), RS with 30 mM H2O2 and/or 0.7 mM FeCl3 and CS) under dynamical loading for five million cycles. Resulting material loss was determined gravimetrically and by ion analysis. The tribo-corrosive material degradation was investigated by light and electron microscopy. FeCl3 enhanced the material loss from taper connections while H2O2 did not lead to a significant alteration of total material loss. In comparison to pure RS, corrosion testing in CS decreased material loss at the head taper while it increased material loss at the trunnion. The combination of FeCl3 and H2O2 led to an enhanced occurrence of micro cracks at the trunnion surface. Adding FeCl3 and optionally also H2O2 aggravates material loss in in vitro corrosion testing of taper junctions and leads to harsher and probably more realistic testing conditions. - Statement of significance - Tribo-corrosive processes at taper connections in hip implants are complex and can lead to major clinical implications. Joint inflammation is assumed to aggravate taper corrosion in vivo, why FeCl3 and H2O2 have been proposed as additives to electrolytes to simulate inflammatory conditions in vitro. Often used fretting test setups, however, do not involve real taper geometries. Besides, testing is often accomplished in saline solutions or calf serum, which do not induce a clinically significant amount of corrosive material degradation. This study presents an approach to increase tribo-corrosive processes at realistic taper connections by adding FeCl3 and/or H2O2. Unlike H2O2, FeCl3 increased material loss from taper connections. The combination of both additives enhanced micro crack formation at the trunnion surfaces. 
650 4 |a Corrosion 
650 4 |a Electrolyte 
650 4 |a Inflammation 
650 4 |a Taper 
650 4 |a Total hip arthroplasty 
700 1 |a Nebel, Laura  |e VerfasserIn  |0 (DE-588)1211029832  |0 (DE-627)1698890389  |4 aut 
700 1 |a Müller, Ulrike  |d 1988-  |e VerfasserIn  |0 (DE-588)1116644002  |0 (DE-627)870607081  |0 (DE-576)478555504  |4 aut 
700 1 |a Mai, Phuong Thao  |e VerfasserIn  |0 (DE-588)1257271776  |0 (DE-627)1801400016  |4 aut 
700 1 |a Gibmeier, Jens  |e VerfasserIn  |4 aut 
700 1 |a Renkawitz, Tobias  |d 1976-  |e VerfasserIn  |0 (DE-588)129303615  |0 (DE-627)392614979  |0 (DE-576)297588028  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
773 0 8 |i Enthalten in  |t Acta biomaterialia  |d [Amsterdam] : Elsevier, 2005  |g 145(2022), Seite 427-435  |h Online-Ressource  |w (DE-627)477531210  |w (DE-600)2173841-5  |w (DE-576)255605226  |x 1878-7568  |7 nnas  |a Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty an in vitro study 
773 1 8 |g volume:145  |g year:2022  |g pages:427-435  |g extent:9  |a Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty an in vitro study 
856 4 0 |u https://doi.org/10.1016/j.actbio.2022.04.007  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1742706122002112  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230414 
993 |a Article 
994 |a 2022 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |d 50000  |e 910000PK136998348  |e 911460PK136998348  |e 50000PK136998348  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 7  |y j 
998 |g 129303615  |a Renkawitz, Tobias  |m 129303615:Renkawitz, Tobias  |d 910000  |d 911460  |e 910000PR129303615  |e 911460PR129303615  |k 0/910000/  |k 1/910000/911460/  |p 6 
998 |g 1205894829  |a Bormann, Therese  |m 1205894829:Bormann, Therese  |d 910000  |d 911460  |e 910000PB1205894829  |e 911460PB1205894829  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1842707698  |e 4308967171 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"June 2022","dateIssuedKey":"2022"}],"note":["Im Titel sind die Zahlen 3 und 2 jeweils tiefgestellt","Gesehen am 14.04.2022"],"title":[{"title_sort":"Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty","subtitle":"an in vitro study","title":"Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"part":{"pages":"427-435","year":"2022","text":"145(2022), Seite 427-435","extent":"9","volume":"145"},"language":["eng"],"disp":"Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty an in vitro studyActa biomaterialia","type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"Acta biomaterialia","title":"Acta biomaterialia"}],"origin":[{"publisher":"Elsevier","dateIssuedKey":"2005","dateIssuedDisp":"2005-","publisherPlace":"[Amsterdam]"}],"pubHistory":["1.2005 -"],"note":["Gesehen am 09.09.2020"],"id":{"eki":["477531210"],"issn":["1878-7568"],"zdb":["2173841-5"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"477531210"}],"recId":"1842707698","name":{"displayForm":["Therese Bormann, Laura Nebel, Ulrike Müller, Phuong Thao Mai, Jens Gibmeier, Tobias Renkawitz, J. Philippe Kretzer"]},"physDesc":[{"extent":"9 S."}],"id":{"doi":["10.1016/j.actbio.2022.04.007"],"eki":["1842707698"]},"person":[{"given":"Therese","role":"aut","display":"Bormann, Therese","family":"Bormann"},{"role":"aut","given":"Laura","display":"Nebel, Laura","family":"Nebel"},{"display":"Müller, Ulrike","family":"Müller","role":"aut","given":"Ulrike"},{"display":"Mai, Phuong Thao","family":"Mai","role":"aut","given":"Phuong Thao"},{"role":"aut","given":"Jens","display":"Gibmeier, Jens","family":"Gibmeier"},{"family":"Renkawitz","display":"Renkawitz, Tobias","role":"aut","given":"Tobias"},{"role":"aut","given":"Jan Philippe","family":"Kretzer","display":"Kretzer, Jan Philippe"}],"language":["eng"],"titleAlt":[{"title":"Influence of FeCl 3 and H 2 O 2 in corrosion testing of modular taper connections in total hip arthroplasty"}]} 
SRT |a BORMANNTHEINFLUENCEO2022