High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries: comparison with contrast-enhanced MR angiography

OBJECTIVE. The aim of this study is to determine the diagnostic value of high-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography (MRA) of the renal arteries using a steady-state free precession (SSFP) technique in comparison with 1.0-molar contrast-enhanced MRA in patients with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mohrs, Oliver K. (VerfasserIn) , Petersen, Steffen E. (VerfasserIn) , Schulze, Thomas (VerfasserIn) , Zieschang, Michael (VerfasserIn) , Küx, Harald (VerfasserIn) , Schmitt, Peter (VerfasserIn) , Bergemann, Sabine (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2010
In: American journal of roentgenology
Year: 2010, Jahrgang: 195, Heft: 6, Pages: 1423-1428
ISSN:1546-3141
DOI:10.2214/AJR.10.4365
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2214/AJR.10.4365
Verlag, lizenzpflichtig, Volltext: https://www.ajronline.org/doi/10.2214/AJR.10.4365
Volltext
Verfasserangaben:Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor

MARC

LEADER 00000caa a2200000 c 4500
001 1843789930
003 DE-627
005 20230710141700.0
007 cr uuu---uuuuu
008 230428s2010 xx |||||o 00| ||eng c
024 7 |a 10.2214/AJR.10.4365  |2 doi 
035 |a (DE-627)1843789930 
035 |a (DE-599)KXP1843789930 
035 |a (OCoLC)1389806062 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mohrs, Oliver K.  |d 1974-  |e VerfasserIn  |0 (DE-588)122659201  |0 (DE-627)082074216  |0 (DE-576)293368376  |4 aut 
245 1 0 |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries  |b comparison with contrast-enhanced MR angiography  |c Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor 
264 1 |c 2010 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.04.2023 
520 |a OBJECTIVE. The aim of this study is to determine the diagnostic value of high-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography (MRA) of the renal arteries using a steady-state free precession (SSFP) technique in comparison with 1.0-molar contrast-enhanced MRA in patients with suspected renal artery stenosis. - - SUBJECTS AND METHODS. Forty-five consecutive patients underwent unenhanced MRA before contrast-enhanced MRA within the same session. We assessed examination time, image quality, renal artery architecture, and localization and severity of renal artery stenosis. - - RESULTS. Examination time was shorter for contrast-enhanced MRA (mean ± SD, 12 ± 3 minutes) than for unenhanced MRA (19 ± 3 minutes; p < 0.001). On a 5-point scale, the image quality was similar for contrast-enhanced MRA (3.8 ± 1.0) and unenhanced MRA (4.0 ± 1.3; p = 0.24). Contrast-enhanced MRA offered more assessable data sets than did unenhanced MRA (95% vs 90%); however, unenhanced MRA had more data sets with maximum image quality (49% vs 30%). There was moderate agreement in stenosis grading between both MRA techniques (κ = 0.51; p < 0.001), but in only one case (1.3%) we found mismatch of more than one severity stenosis grade (stenoses > 75%). Sensitivity, specificity, and positive and negative predictive values of unenhanced MRA to detect renal artery stenoses greater than 50% were 75%, 99%, 75%, and 99%, respectively. - - CONCLUSION. We show that SSFP 3D unenhanced MRA is a very promising technique for patients with suspected renovascular disease and could be used as an alternative if gadolinium-based contrast agents cannot be administered. 
650 4 |a contrast agent 
650 4 |a MR angiography 
650 4 |a peripheral artery disease 
650 4 |a renal artery 
650 4 |a unenhanced 
700 1 |a Petersen, Steffen E.  |e VerfasserIn  |4 aut 
700 1 |a Schulze, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Zieschang, Michael  |e VerfasserIn  |4 aut 
700 1 |a Küx, Harald  |e VerfasserIn  |4 aut 
700 1 |a Schmitt, Peter  |e VerfasserIn  |4 aut 
700 1 |a Bergemann, Sabine  |e VerfasserIn  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
773 0 8 |i Enthalten in  |t American journal of roentgenology  |d Leesburg, Va. : American Roentgen Ray Society, 1965  |g 195(2010), 6 vom: Okt., Seite 1423-1428  |h Online-Ressource  |w (DE-627)320501086  |w (DE-600)2012224-X  |w (DE-576)094113602  |x 1546-3141  |7 nnas  |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiography 
773 1 8 |g volume:195  |g year:2010  |g number:6  |g month:10  |g pages:1423-1428  |g extent:6  |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiography 
856 4 0 |u https://doi.org/10.2214/AJR.10.4365  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ajronline.org/doi/10.2214/AJR.10.4365  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230428 
993 |a Article 
994 |a 2010 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8  |y j 
998 |g 122659201  |a Mohrs, Oliver K.  |m 122659201:Mohrs, Oliver K.  |d 50000  |e 50000PM122659201  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1843789930  |e 4315985643 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 28.04.2023"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"subtitle":"comparison with contrast-enhanced MR angiography","title":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries","title_sort":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries"}],"relHost":[{"titleAlt":[{"title":"AJR"},{"title":"The American journal of roentgenology, radium therapy and nuclear medicine"}],"pubHistory":["Nachgewiesen 95.1965 -"],"name":{"displayForm":["American Roentgen Ray Society"]},"part":{"year":"2010","volume":"195","pages":"1423-1428","issue":"6","text":"195(2010), 6 vom: Okt., Seite 1423-1428","extent":"6"},"id":{"issn":["1546-3141"],"eki":["320501086"],"zdb":["2012224-X"]},"origin":[{"publisher":"American Roentgen Ray Society ; Highwire Press","publisherPlace":"Leesburg, Va. ; Stanford, Calif.","dateIssuedDisp":"[1965?]-"}],"title":[{"subtitle":"AJR","title_sort":"American journal of roentgenology","title":"American journal of roentgenology"}],"note":["Gesehen am 27.08.2025","Fortsetzung der Druck-Ausgabe"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"320501086","physDesc":[{"extent":"Online-Ressource"}],"disp":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiographyAmerican journal of roentgenology"}],"person":[{"display":"Mohrs, Oliver K.","family":"Mohrs","given":"Oliver K.","role":"aut"},{"role":"aut","given":"Steffen E.","family":"Petersen","display":"Petersen, Steffen E."},{"display":"Schulze, Thomas","family":"Schulze","role":"aut","given":"Thomas"},{"given":"Michael","role":"aut","family":"Zieschang","display":"Zieschang, Michael"},{"display":"Küx, Harald","given":"Harald","role":"aut","family":"Küx"},{"role":"aut","given":"Peter","family":"Schmitt","display":"Schmitt, Peter"},{"family":"Bergemann","given":"Sabine","role":"aut","display":"Bergemann, Sabine"},{"role":"aut","given":"Hans-Ulrich","family":"Kauczor","display":"Kauczor, Hans-Ulrich"}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"2010"}],"physDesc":[{"extent":"6 S."}],"recId":"1843789930","id":{"doi":["10.2214/AJR.10.4365"],"eki":["1843789930"]},"name":{"displayForm":["Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor"]}} 
SRT |a MOHRSOLIVEHIGHRESOLU2010