High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries: comparison with contrast-enhanced MR angiography
OBJECTIVE. The aim of this study is to determine the diagnostic value of high-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography (MRA) of the renal arteries using a steady-state free precession (SSFP) technique in comparison with 1.0-molar contrast-enhanced MRA in patients with...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2010
|
| In: |
American journal of roentgenology
Year: 2010, Jahrgang: 195, Heft: 6, Pages: 1423-1428 |
| ISSN: | 1546-3141 |
| DOI: | 10.2214/AJR.10.4365 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2214/AJR.10.4365 Verlag, lizenzpflichtig, Volltext: https://www.ajronline.org/doi/10.2214/AJR.10.4365 |
| Verfasserangaben: | Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1843789930 | ||
| 003 | DE-627 | ||
| 005 | 20230710141700.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230428s2010 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.2214/AJR.10.4365 |2 doi | |
| 035 | |a (DE-627)1843789930 | ||
| 035 | |a (DE-599)KXP1843789930 | ||
| 035 | |a (OCoLC)1389806062 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Mohrs, Oliver K. |d 1974- |e VerfasserIn |0 (DE-588)122659201 |0 (DE-627)082074216 |0 (DE-576)293368376 |4 aut | |
| 245 | 1 | 0 | |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries |b comparison with contrast-enhanced MR angiography |c Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor |
| 264 | 1 | |c 2010 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 28.04.2023 | ||
| 520 | |a OBJECTIVE. The aim of this study is to determine the diagnostic value of high-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography (MRA) of the renal arteries using a steady-state free precession (SSFP) technique in comparison with 1.0-molar contrast-enhanced MRA in patients with suspected renal artery stenosis. - - SUBJECTS AND METHODS. Forty-five consecutive patients underwent unenhanced MRA before contrast-enhanced MRA within the same session. We assessed examination time, image quality, renal artery architecture, and localization and severity of renal artery stenosis. - - RESULTS. Examination time was shorter for contrast-enhanced MRA (mean ± SD, 12 ± 3 minutes) than for unenhanced MRA (19 ± 3 minutes; p < 0.001). On a 5-point scale, the image quality was similar for contrast-enhanced MRA (3.8 ± 1.0) and unenhanced MRA (4.0 ± 1.3; p = 0.24). Contrast-enhanced MRA offered more assessable data sets than did unenhanced MRA (95% vs 90%); however, unenhanced MRA had more data sets with maximum image quality (49% vs 30%). There was moderate agreement in stenosis grading between both MRA techniques (κ = 0.51; p < 0.001), but in only one case (1.3%) we found mismatch of more than one severity stenosis grade (stenoses > 75%). Sensitivity, specificity, and positive and negative predictive values of unenhanced MRA to detect renal artery stenoses greater than 50% were 75%, 99%, 75%, and 99%, respectively. - - CONCLUSION. We show that SSFP 3D unenhanced MRA is a very promising technique for patients with suspected renovascular disease and could be used as an alternative if gadolinium-based contrast agents cannot be administered. | ||
| 650 | 4 | |a contrast agent | |
| 650 | 4 | |a MR angiography | |
| 650 | 4 | |a peripheral artery disease | |
| 650 | 4 | |a renal artery | |
| 650 | 4 | |a unenhanced | |
| 700 | 1 | |a Petersen, Steffen E. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Schulze, Thomas |e VerfasserIn |4 aut | |
| 700 | 1 | |a Zieschang, Michael |e VerfasserIn |4 aut | |
| 700 | 1 | |a Küx, Harald |e VerfasserIn |4 aut | |
| 700 | 1 | |a Schmitt, Peter |e VerfasserIn |4 aut | |
| 700 | 1 | |a Bergemann, Sabine |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t American journal of roentgenology |d Leesburg, Va. : American Roentgen Ray Society, 1965 |g 195(2010), 6 vom: Okt., Seite 1423-1428 |h Online-Ressource |w (DE-627)320501086 |w (DE-600)2012224-X |w (DE-576)094113602 |x 1546-3141 |7 nnas |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiography |
| 773 | 1 | 8 | |g volume:195 |g year:2010 |g number:6 |g month:10 |g pages:1423-1428 |g extent:6 |a High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiography |
| 856 | 4 | 0 | |u https://doi.org/10.2214/AJR.10.4365 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.ajronline.org/doi/10.2214/AJR.10.4365 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230428 | ||
| 993 | |a Article | ||
| 994 | |a 2010 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 8 |y j | ||
| 998 | |g 122659201 |a Mohrs, Oliver K. |m 122659201:Mohrs, Oliver K. |d 50000 |e 50000PM122659201 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1843789930 |e 4315985643 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 28.04.2023"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"subtitle":"comparison with contrast-enhanced MR angiography","title":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries","title_sort":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries"}],"relHost":[{"titleAlt":[{"title":"AJR"},{"title":"The American journal of roentgenology, radium therapy and nuclear medicine"}],"pubHistory":["Nachgewiesen 95.1965 -"],"name":{"displayForm":["American Roentgen Ray Society"]},"part":{"year":"2010","volume":"195","pages":"1423-1428","issue":"6","text":"195(2010), 6 vom: Okt., Seite 1423-1428","extent":"6"},"id":{"issn":["1546-3141"],"eki":["320501086"],"zdb":["2012224-X"]},"origin":[{"publisher":"American Roentgen Ray Society ; Highwire Press","publisherPlace":"Leesburg, Va. ; Stanford, Calif.","dateIssuedDisp":"[1965?]-"}],"title":[{"subtitle":"AJR","title_sort":"American journal of roentgenology","title":"American journal of roentgenology"}],"note":["Gesehen am 27.08.2025","Fortsetzung der Druck-Ausgabe"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"320501086","physDesc":[{"extent":"Online-Ressource"}],"disp":"High-resolution 3D unenhanced ECG-gated respiratory-navigated MR angiography of the renal arteries comparison with contrast-enhanced MR angiographyAmerican journal of roentgenology"}],"person":[{"display":"Mohrs, Oliver K.","family":"Mohrs","given":"Oliver K.","role":"aut"},{"role":"aut","given":"Steffen E.","family":"Petersen","display":"Petersen, Steffen E."},{"display":"Schulze, Thomas","family":"Schulze","role":"aut","given":"Thomas"},{"given":"Michael","role":"aut","family":"Zieschang","display":"Zieschang, Michael"},{"display":"Küx, Harald","given":"Harald","role":"aut","family":"Küx"},{"role":"aut","given":"Peter","family":"Schmitt","display":"Schmitt, Peter"},{"family":"Bergemann","given":"Sabine","role":"aut","display":"Bergemann, Sabine"},{"role":"aut","given":"Hans-Ulrich","family":"Kauczor","display":"Kauczor, Hans-Ulrich"}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"2010"}],"physDesc":[{"extent":"6 S."}],"recId":"1843789930","id":{"doi":["10.2214/AJR.10.4365"],"eki":["1843789930"]},"name":{"displayForm":["Oliver K. Mohrs, Steffen E. Petersen, Thomas Schulze, Michael Zieschang, Harald Küx, Peter Schmitt, Sabine Bergemann and Hans-Ulrich Kauczor"]}} | ||
| SRT | |a MOHRSOLIVEHIGHRESOLU2010 | ||