Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma: a potential alternative to the Patlak model of CT perfusion

Introduction - By using bolus tracking with an appropriate acquisition delay dual-energy computed tomography (DECT) iodine maps might serve as a replacement of CT perfusion maps at reduced radiation exposure. This study aimed to evaluate the optimal acquisition delays of DECT for the replacement of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Skornitzke, Stephan (VerfasserIn) , Mayer, Philipp (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Stiller, Wolfram (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: April 2023
In: Heliyon
Year: 2023, Jahrgang: 9, Heft: 4, Pages: 1-12
ISSN:2405-8440
DOI:10.1016/j.heliyon.2023.e14726
Online-Zugang:Resolving-System, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.heliyon.2023.e14726
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S2405844023019333
Volltext
Verfasserangaben:Stephan Skornitzke, Philipp Mayer, Hans-Ulrich Kauczor, Wolfram Stiller

MARC

LEADER 00000caa a2200000 c 4500
001 1844484378
003 DE-627
005 20240327080247.0
007 cr uuu---uuuuu
008 230503s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.heliyon.2023.e14726  |2 doi 
035 |a (DE-627)1844484378 
035 |a (DE-599)KXP1844484378 
035 |a (OCoLC)1389530466 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
245 1 0 |a Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma  |b a potential alternative to the Patlak model of CT perfusion  |c Stephan Skornitzke, Philipp Mayer, Hans-Ulrich Kauczor, Wolfram Stiller 
264 1 |c April 2023 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.05.2023 
520 |a Introduction - By using bolus tracking with an appropriate acquisition delay dual-energy computed tomography (DECT) iodine maps might serve as a replacement of CT perfusion maps at reduced radiation exposure. This study aimed to evaluate the optimal acquisition delays of DECT for the replacement of parameter maps calculated with the Patlak model in pancreatic adenocarcinoma by corresponding iodine maps. - Materials and methods - Dual-source dynamic DECT acquisitions at 80 kVp/Sn140 kVp of 14 patients with pancreatic carcinoma were used to calculate CT perfusion maps of blood volume and permeability with the Patlak model. DECT iodine maps were generated from individual DECT acquisitions, matching acquisition times relative to prior bolus-triggered three-phase CT acquisitions for investigating different acquisition delays. Correlation between perfusion parameters and iodine concentrations was determined for acquisition delays between −6 s and 33 s. - Results - Correlation between iodine concentrations and perfusion parameters ranged from −0.05 to 0.63 for blood volume and from −0.05 to 0.71 for permeability, depending on potential trigger delay. The correlation was significant for potential acquisition delays above 1.5 s for blood volume and above 9.0 s for permeability (both p < 0.05). Maximum correlation occurred at an acquisition delay of 15.0 s for blood volume (r = 0.63) and at 25.5 s for permeability (r = 0.71), with significantly lower iodine concentrations in carcinoma (15.0 s: 1.3 ± 0.5 mg/ml; 22.5 s: 1.4 ± 0.7 mg/ml) than in non-neoplastic pancreatic parenchyma (15.0 s: 2.3 ± 0.8 mg/ml; 22.5 s: 2.4 ± 0.6 mg/ml; p < 0.05). - Discussion - In the future, well-timed DECT iodine maps acquired with bolus tracking could provide an alternative to permeability and blood volume maps calculated with the Patlak model. 
650 4 |a CT perfusion 
650 4 |a Dual-energy CT 
650 4 |a Iodine quantification 
650 4 |a Pancreatic carcinoma 
700 1 |a Mayer, Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1066605440  |0 (DE-627)817714758  |0 (DE-576)426052250  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
773 0 8 |i Enthalten in  |t Heliyon  |d London [u.a.] : Elsevier, 2015  |g 9(2023), 4 vom: Apr., Artikel-ID e14726, Seite 1-12  |h Online-Ressource  |w (DE-627)835893197  |w (DE-600)2835763-2  |w (DE-576)445959371  |x 2405-8440  |7 nnas  |a Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma a potential alternative to the Patlak model of CT perfusion 
773 1 8 |g volume:9  |g year:2023  |g number:4  |g month:04  |g elocationid:e14726  |g pages:1-12  |g extent:12  |a Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma a potential alternative to the Patlak model of CT perfusion 
856 4 0 |u https://doi.org/10.1016/j.heliyon.2023.e14726  |x Resolving-System  |x Verlag  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S2405844023019333  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230503 
993 |a Article 
994 |a 2023 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |d 50000  |e 910000PS105822672X  |e 911400PS105822672X  |e 50000PS105822672X  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 4  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 1066605440  |a Mayer, Philipp  |m 1066605440:Mayer, Philipp  |d 910000  |d 911400  |e 910000PM1066605440  |e 911400PM1066605440  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 50000  |e 50000PS1110072589  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1844484378  |e 4317638371 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1844484378","person":[{"role":"aut","family":"Skornitzke","display":"Skornitzke, Stephan","given":"Stephan"},{"given":"Philipp","display":"Mayer, Philipp","role":"aut","family":"Mayer"},{"family":"Kauczor","role":"aut","display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich"},{"given":"Wolfram","display":"Stiller, Wolfram","role":"aut","family":"Stiller"}],"note":["Gesehen am 03.05.2023"],"language":["eng"],"name":{"displayForm":["Stephan Skornitzke, Philipp Mayer, Hans-Ulrich Kauczor, Wolfram Stiller"]},"relHost":[{"pubHistory":["1.2015 -"],"note":["Gesehen am 28.05.20"],"part":{"year":"2023","volume":"9","issue":"4","pages":"1-12","extent":"12","text":"9(2023), 4 vom: Apr., Artikel-ID e14726, Seite 1-12"},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma a potential alternative to the Patlak model of CT perfusionHeliyon","recId":"835893197","origin":[{"publisherPlace":"London [u.a.]","dateIssuedKey":"2015","dateIssuedDisp":"2015-","publisher":"Elsevier"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["835893197"],"issn":["2405-8440"],"zdb":["2835763-2"]},"title":[{"title_sort":"Heliyon","title":"Heliyon"}]}],"origin":[{"dateIssuedDisp":"April 2023","dateIssuedKey":"2023"}],"title":[{"title":"Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma","subtitle":"a potential alternative to the Patlak model of CT perfusion","title_sort":"Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1844484378"],"doi":["10.1016/j.heliyon.2023.e14726"]},"physDesc":[{"extent":"12 S."}]} 
SRT |a SKORNITZKEEVALUATION2023