Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Heußel, Claus Peter (VerfasserIn) , Kappes, Jutta (VerfasserIn) , Finsterer, Romy (VerfasserIn) , Hartlieb, Sissel (VerfasserIn) , Weinheimer, O. (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Eberhardt, Ralf (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [June 2010]
In: European journal of radiology
Year: 2010, Jahrgang: 74, Heft: 3, Pages: 473-478
ISSN:1872-7727
DOI:10.1016/j.ejrad.2009.03.023
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2009.03.023
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X09001363
Volltext
Verfasserangaben:C.P. Heussel, J. Kappes, R. Hantusch, S. Hartlieb, O. Weinheimer, H. -U. Kauczor, R. Eberhardt

MARC

LEADER 00000caa a2200000 c 4500
001 184495417X
003 DE-627
005 20230710135015.0
007 cr uuu---uuuuu
008 230510s2010 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2009.03.023  |2 doi 
035 |a (DE-627)184495417X 
035 |a (DE-599)KXP184495417X 
035 |a (OCoLC)1389805762 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Heußel, Claus Peter  |e VerfasserIn  |0 (DE-588)1048631389  |0 (DE-627)780769422  |0 (DE-576)40288146X  |4 aut 
245 1 0 |a Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification  |c C.P. Heussel, J. Kappes, R. Hantusch, S. Hartlieb, O. Weinheimer, H. -U. Kauczor, R. Eberhardt 
264 1 |c [June 2010] 
300 |b Illustrationen 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 10.05.2023 
520 |a Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used. 
650 4 |a Contrast enhancement 
650 4 |a COPD 
650 4 |a Diagnostic imaging 
650 4 |a Lung attenuation 
650 4 |a MDCT imaging techniques in COPD 
700 1 |a Kappes, Jutta  |e VerfasserIn  |0 (DE-588)107507195X  |0 (DE-627)832912832  |0 (DE-576)175883572  |4 aut 
700 1 |a Finsterer, Romy  |d 1981-  |e VerfasserIn  |0 (DE-588)115998655X  |0 (DE-627)1023106302  |0 (DE-576)505437775  |4 aut 
700 1 |a Hartlieb, Sissel  |d 1975-  |e VerfasserIn  |0 (DE-588)132283611  |0 (DE-627)520404890  |0 (DE-576)276495829  |4 aut 
700 1 |a Weinheimer, O.  |e VerfasserIn  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Eberhardt, Ralf  |e VerfasserIn  |0 (DE-588)1055080406  |0 (DE-627)792649133  |0 (DE-576)176462120  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 74(2010), 3 vom: Juni, Seite 473-478  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification 
773 1 8 |g volume:74  |g year:2010  |g number:3  |g month:06  |g pages:473-478  |g extent:6  |a Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2009.03.023  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X09001363  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230510 
993 |a Article 
994 |a 2010 
998 |g 1055080406  |a Eberhardt, Ralf  |m 1055080406:Eberhardt, Ralf  |d 910000  |d 950000  |d 950900  |e 910000PE1055080406  |e 950000PE1055080406  |e 950900PE1055080406  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 7  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 132283611  |a Hartlieb, Sissel  |m 132283611:Hartlieb, Sissel  |d 910000  |d 950000  |d 950900  |e 910000PH132283611  |e 950000PH132283611  |e 950900PH132283611  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 4 
998 |g 115998655X  |a Finsterer, Romy  |m 115998655X:Finsterer, Romy  |d 910000  |d 950000  |d 950900  |e 910000PF115998655X  |e 950000PF115998655X  |e 950900PF115998655X  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 3 
998 |g 107507195X  |a Kappes, Jutta  |m 107507195X:Kappes, Jutta  |d 910000  |d 950000  |d 950900  |e 910000PK107507195X  |e 950000PK107507195X  |e 950900PK107507195X  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 2 
998 |g 1048631389  |a Heußel, Claus Peter  |m 1048631389:Heußel, Claus Peter  |d 910000  |d 950000  |d 950900  |d 50000  |e 910000PH1048631389  |e 950000PH1048631389  |e 950900PH1048631389  |e 50000PH1048631389  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN184495417X  |e 4320241150 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"family":"Heußel","display":"Heußel, Claus Peter","role":"aut","given":"Claus Peter"},{"family":"Kappes","display":"Kappes, Jutta","given":"Jutta","role":"aut"},{"role":"aut","given":"Romy","family":"Finsterer","display":"Finsterer, Romy"},{"role":"aut","given":"Sissel","display":"Hartlieb, Sissel","family":"Hartlieb"},{"family":"Weinheimer","display":"Weinheimer, O.","given":"O.","role":"aut"},{"given":"Hans-Ulrich","role":"aut","display":"Kauczor, Hans-Ulrich","family":"Kauczor"},{"role":"aut","given":"Ralf","display":"Eberhardt, Ralf","family":"Eberhardt"}],"id":{"doi":["10.1016/j.ejrad.2009.03.023"],"eki":["184495417X"]},"name":{"displayForm":["C.P. Heussel, J. Kappes, R. Hantusch, S. Hartlieb, O. Weinheimer, H. -U. Kauczor, R. Eberhardt"]},"physDesc":[{"extent":"6 S.","noteIll":"Illustrationen"}],"recId":"184495417X","relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantificationEuropean journal of radiology","title":[{"title":"European journal of radiology","subtitle":"EJR","title_sort":"European journal of radiology"}],"origin":[{"dateIssuedDisp":"1990-","publisher":"Elsevier Science","dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]"}],"note":["Gesehen am 05.02.20"],"pubHistory":["Nachgewiesen 10.1990 -"],"id":{"issn":["1872-7727"],"zdb":["2005350-2"],"eki":["32044483X"]},"recId":"32044483X","physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"3","text":"74(2010), 3 vom: Juni, Seite 473-478","pages":"473-478","year":"2010","extent":"6","volume":"74"},"titleAlt":[{"title":"EJR"}],"language":["eng"]}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 10.05.2023"],"origin":[{"dateIssuedDisp":"[June 2010]","dateIssuedKey":"2010"}],"title":[{"title_sort":"Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification","title":"Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification"}]} 
SRT |a HEUSSELCLACONTRASTEN2010