Radiation dose at coronary CT angiography: second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT

OBJECTIVE. The purpose of this study was to assess the radiation doses of different coronary CTA (CTA) protocols: second-generation dual-source 128-MDCT, first-generation dual-source 64-MDCT, and single-source 64-MDCT. MATERIALS AND METHODS. Thermoluminescent dosimetry was used to determine scanner-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fink, Christian (VerfasserIn) , Kriššák, Radko (VerfasserIn) , Henzler, Thomas (VerfasserIn) , Lechel, Ursula (VerfasserIn) , Brix, Gunnar (VerfasserIn) , Takx, Richard A. P. (VerfasserIn) , Nance, John W. (VerfasserIn) , Abro, Joseph A. (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Schoepf, U. Joseph (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: American journal of roentgenology
Year: 2011, Jahrgang: 196, Heft: 5, Pages: W550-W557
ISSN:0361-803X
DOI:10.2214/AJR.10.5153
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2214/AJR.10.5153
Verlag, lizenzpflichtig, Volltext: https://www.ajronline.org/doi/10.2214/AJR.10.5153
Volltext
Verfasserangaben:Christian Fink, Radko Krissak, Thomas Henzler, Ursula Lechel, Gunnar Brix, Richard A.P. Takx, John W. Nance, Joseph A. Abro, Stefan O. Schoenberg, U. Joseph Schoepf

MARC

LEADER 00000caa a2200000 c 4500
001 1845127595
003 DE-627
005 20230710093850.0
007 cr uuu---uuuuu
008 230511s2011 xx |||||o 00| ||eng c
024 7 |a 10.2214/AJR.10.5153  |2 doi 
035 |a (DE-627)1845127595 
035 |a (DE-599)KXP1845127595 
035 |a (OCoLC)1389738034 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Fink, Christian  |d 1971-  |e VerfasserIn  |0 (DE-588)121198014  |0 (DE-627)705299767  |0 (DE-576)292581882  |4 aut 
245 1 0 |a Radiation dose at coronary CT angiography  |b second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT  |c Christian Fink, Radko Krissak, Thomas Henzler, Ursula Lechel, Gunnar Brix, Richard A.P. Takx, John W. Nance, Joseph A. Abro, Stefan O. Schoenberg, U. Joseph Schoepf 
264 1 |c 2011 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.05.2023 
500 |a nach Überarbeitung angenommen September 24, 2010 
520 |a OBJECTIVE. The purpose of this study was to assess the radiation doses of different coronary CTA (CTA) protocols: second-generation dual-source 128-MDCT, first-generation dual-source 64-MDCT, and single-source 64-MDCT. MATERIALS AND METHODS. Thermoluminescent dosimetry was used to determine scanner-specific dose coefficients for standard coronary CTA of an anthropomorphic phantom. These coefficients were used to estimate the effective doses (EDs) of retrospectively gated, prospectively triggered, and prospectively triggered high pitch coronary CTA performed at 100 and 120 kV. The coronary CTA protocols used in imaging of 43 patients undergoing dual-source 128-MDCT were analyzed for ED, image quality, and signal-to-noise ratio. RESULTS. Regardless of coronary CTA protocol and CT system, imaging at 100 kV lowered the ED 40-50%. In retrospectively gated 120-kV coronary CTA, the ED ranged from 5.7 to 10.7 mSv and was approximately 50% lower with single-source 64-MDCT than with either DSCT protocol. In prospectively triggered 120-kV coronary CTA, the ED ranged from 3.8 to 4.0 mSv. The lowest ED of all protocols (1.3 mSv) was observed in prospectively triggered high-pitch 100-kV coronary CTA performed with dual-source 128-MDCT. Patient measurements showed similar dose reductions for prospective triggering and low voltage settings without an influence on signal-to-noise ratio or image quality. CONCLUSION. A combination of prospective triggering with low voltage settings is an effective measure for reducing the ED of coronary CTA to values of 2-4 mSv independent of scanner system. Further dose reduction to nearly 1 mSv can be achieved with high-pitch prospectively triggered coronary CTA. 
650 4 |a coronary angiography 
650 4 |a CT 
650 4 |a phantom study 
650 4 |a radiation exposure 
700 1 |a Kriššák, Radko  |d 1980-  |e VerfasserIn  |0 (DE-588)133904091  |0 (DE-627)557959128  |0 (DE-576)276900936  |4 aut 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Lechel, Ursula  |e VerfasserIn  |4 aut 
700 1 |a Brix, Gunnar  |e VerfasserIn  |4 aut 
700 1 |a Takx, Richard A. P.  |e VerfasserIn  |4 aut 
700 1 |a Nance, John W.  |e VerfasserIn  |4 aut 
700 1 |a Abro, Joseph A.  |e VerfasserIn  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Schoepf, U. Joseph  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t American journal of roentgenology  |d Leesburg, Va. : American Roentgen Ray Society, 1965  |g 196(2011), 5 vom: Mai, Seite W550-W557  |w (DE-627)129271551  |w (DE-600)82076-3  |w (DE-576)014462273  |x 0361-803X  |7 nnas  |a Radiation dose at coronary CT angiography second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT 
773 1 8 |g volume:196  |g year:2011  |g number:5  |g month:05  |g pages:W550-W557  |g extent:8  |a Radiation dose at coronary CT angiography second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT 
856 4 0 |u https://doi.org/10.2214/AJR.10.5153  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ajronline.org/doi/10.2214/AJR.10.5153  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230511 
993 |a Article 
994 |a 2011 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |d 60000  |e 60000PS131557912  |e 62900PS131557912  |e 60000PS131557912  |k 0/60000/  |k 1/60000/62900/  |k 0/60000/  |p 9 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 3 
998 |g 133904091  |a Kriššák, Radko  |m 133904091:Kriššák, Radko  |d 60000  |d 62900  |e 60000PK133904091  |e 62900PK133904091  |k 0/60000/  |k 1/60000/62900/  |p 2 
998 |g 121198014  |a Fink, Christian  |m 121198014:Fink, Christian  |d 60000  |d 62900  |e 60000PF121198014  |e 62900PF121198014  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1845127595  |e 4320612191 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1845127595","physDesc":[{"extent":"8 S."}],"language":["eng"],"id":{"doi":["10.2214/AJR.10.5153"],"eki":["1845127595"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Radiation dose at coronary CT angiography","subtitle":"second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT","title":"Radiation dose at coronary CT angiography"}],"person":[{"roleDisplay":"VerfasserIn","family":"Fink","display":"Fink, Christian","given":"Christian","role":"aut"},{"family":"Kriššák","display":"Kriššák, Radko","roleDisplay":"VerfasserIn","role":"aut","given":"Radko"},{"given":"Thomas","role":"aut","display":"Henzler, Thomas","family":"Henzler","roleDisplay":"VerfasserIn"},{"family":"Lechel","display":"Lechel, Ursula","roleDisplay":"VerfasserIn","role":"aut","given":"Ursula"},{"roleDisplay":"VerfasserIn","family":"Brix","display":"Brix, Gunnar","given":"Gunnar","role":"aut"},{"given":"Richard A. P.","role":"aut","display":"Takx, Richard A. P.","family":"Takx","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Nance","display":"Nance, John W.","role":"aut","given":"John W."},{"given":"Joseph A.","role":"aut","roleDisplay":"VerfasserIn","family":"Abro","display":"Abro, Joseph A."},{"roleDisplay":"VerfasserIn","family":"Schönberg","display":"Schönberg, Stefan","given":"Stefan","role":"aut"},{"role":"aut","given":"U. Joseph","roleDisplay":"VerfasserIn","display":"Schoepf, U. Joseph","family":"Schoepf"}],"note":["Gesehen am 11.05.2023","nach Überarbeitung angenommen September 24, 2010"],"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011"}],"relHost":[{"origin":[{"publisherPlace":"Leesburg, Va. ; Springfield, Ill. ; Baltimore, Md. ; Reston, Va.","dateIssuedDisp":"[1965?]-December 2023","publisher":"American Roentgen Ray Society ; Thomas ; Williams & Wilkins ; Soc."}],"disp":"Radiation dose at coronary CT angiography second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CTAmerican journal of roentgenology","pubHistory":["95.1965 [?]-volume 221, issue 6 (December 2023)"],"part":{"year":"2011","issue":"5","extent":"8","text":"196(2011), 5 vom: Mai, Seite W550-W557","volume":"196","pages":"W550-W557"},"recId":"129271551","titleAlt":[{"title":"AJR"},{"title":"AJR integrative imaging, lifelong learning for radiology"},{"title":"official journal of the American Roentgen Ray Society"}],"language":["eng"],"id":{"issn":["0361-803X","0092-5381"],"zdb":["82076-3"],"eki":["129271551"]},"type":{"bibl":"periodical"},"note":["2024 fortgesetzt als Online-Ausgabe","Ungezählte Beil. ab 2005: AJR integrative imaging, lifelong learning for radiology"],"title":[{"title_sort":"American journal of roentgenology","subtitle":"AJR ; diagnostic imaging and related sciences","title":"American journal of roentgenology"}]}],"name":{"displayForm":["Christian Fink, Radko Krissak, Thomas Henzler, Ursula Lechel, Gunnar Brix, Richard A.P. Takx, John W. Nance, Joseph A. Abro, Stefan O. Schoenberg, U. Joseph Schoepf"]}} 
SRT |a FINKCHRISTRADIATIOND2011