Clinical assessment of stereoscopic optic disc photographs for glaucoma: the european optic disc assessment trial

Purpose - To determine the diagnostic accuracy of judging optic disc photographs for glaucoma by ophthalmologists. - Design - Evaluation of diagnostic test and technology. - Participants - A total of 243 of 875 invited ophthalmologists in 11 European countries. - Methods - We determined how well eac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Reus, Nicolaas Johannes (VerfasserIn) , Lemij, Hans G. (VerfasserIn) , Garway-Heath, David F. (VerfasserIn) , Airaksinen, P. Juhani (VerfasserIn) , Anton, Alfonso (VerfasserIn) , Bron, Alain M. (VerfasserIn) , Faschinger, Christoph (VerfasserIn) , Holló, Gábor (VerfasserIn) , Iester, Michele (VerfasserIn) , Jonas, Jost B. (VerfasserIn) , Mistlberger, Andrea (VerfasserIn) , Topouzis, Fotis (VerfasserIn) , Zeyen, Thierry G. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 4 January 2010
In: Ophthalmology
Year: 2010, Jahrgang: 117, Heft: 4, Pages: 717-723
ISSN:1549-4713
DOI:10.1016/j.ophtha.2009.09.026
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ophtha.2009.09.026
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0161642009010914
Volltext
Verfasserangaben:Nicolaas J. Reus, Hans G. Lemij, David F. Garway-Heath, P. Juhani Airaksinen, Alfonso Anton, Alain M. Bron, Christoph Faschinger, Gábor Holló, Michele Iester, Jost B. Jonas, Andrea Mistlberger, Fotis Topouzis, Thierry G. Zeyen

MARC

LEADER 00000caa a2200000 c 4500
001 1845381610
003 DE-627
005 20230710133904.0
007 cr uuu---uuuuu
008 230515s2010 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ophtha.2009.09.026  |2 doi 
035 |a (DE-627)1845381610 
035 |a (DE-599)KXP1845381610 
035 |a (OCoLC)1389805573 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Reus, Nicolaas Johannes  |e VerfasserIn  |0 (DE-588)1289418217  |0 (DE-627)1845383672  |4 aut 
245 1 0 |a Clinical assessment of stereoscopic optic disc photographs for glaucoma  |b the european optic disc assessment trial  |c Nicolaas J. Reus, Hans G. Lemij, David F. Garway-Heath, P. Juhani Airaksinen, Alfonso Anton, Alain M. Bron, Christoph Faschinger, Gábor Holló, Michele Iester, Jost B. Jonas, Andrea Mistlberger, Fotis Topouzis, Thierry G. Zeyen 
264 1 |c 4 January 2010 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.05.2023 
520 |a Purpose - To determine the diagnostic accuracy of judging optic disc photographs for glaucoma by ophthalmologists. - Design - Evaluation of diagnostic test and technology. - Participants - A total of 243 of 875 invited ophthalmologists in 11 European countries. - Methods - We determined how well each participant classified 40 healthy eyes and 48 glaucomatous eyes with varying severity of the disease on stereoscopic slides. Duplicate slides were provided for determining intraobserver agreement. All eyes were also imaged with the GDx with variable corneal compensation (GDx-VCC) (Carl Zeiss Meditec AG, Jena, Germany) and the Heidelberg Retina Tomograph (HRT) I (Heidelberg Engineering GmbH, Heidelberg, Germany). Diagnostic accuracies of clinicians were compared with those of the best machine classifiers. - Main Outcome Measures - Accuracy of classification, expressed as sensitivity, specificity, and overall accuracy. Intraobserver agreement (κ). - Results - The overall diagnostic accuracy of ophthalmologists was 80.5% (standard deviation [SD], 6.8; range, 61.4%-94.3%). The machine classifiers outperformed most observers in diagnostic accuracy; the GDx-VCC nerve fiber indicator and the HRT's best classifier correctly classified 93.2% and 89.8% of eyes, respectively. The intraobserver agreement (κ) varied between −0.13 and 1.0 and was on average good (0.7). - Conclusions - In general, ophthalmologists classify optic disc photographs moderately well for detecting glaucoma. There is, however, large variability in diagnostic accuracy among and agreement within clinicians. Common imaging devices outperform most clinicians in classifying optic discs. - Financial Disclosure(s) - Proprietary or commercial disclosure may be found after the references. 
700 1 |a Lemij, Hans G.  |e VerfasserIn  |4 aut 
700 1 |a Garway-Heath, David F.  |e VerfasserIn  |4 aut 
700 1 |a Airaksinen, P. Juhani  |e VerfasserIn  |4 aut 
700 1 |a Anton, Alfonso  |e VerfasserIn  |4 aut 
700 1 |a Bron, Alain M.  |e VerfasserIn  |4 aut 
700 1 |a Faschinger, Christoph  |e VerfasserIn  |4 aut 
700 1 |a Holló, Gábor  |e VerfasserIn  |4 aut 
700 1 |a Iester, Michele  |e VerfasserIn  |4 aut 
700 1 |a Jonas, Jost B.  |d 1958-  |e VerfasserIn  |0 (DE-588)1028286732  |0 (DE-627)730536823  |0 (DE-576)37578537X  |4 aut 
700 1 |a Mistlberger, Andrea  |e VerfasserIn  |4 aut 
700 1 |a Topouzis, Fotis  |e VerfasserIn  |4 aut 
700 1 |a Zeyen, Thierry G.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmology  |d Amsterdam [u.a.] : Elsevier, 1978  |g 117(2010), 4 vom: Jan., Seite 717-723  |h Online-Ressource  |w (DE-627)320526941  |w (DE-600)2015287-5  |w (DE-576)121465691  |x 1549-4713  |7 nnas  |a Clinical assessment of stereoscopic optic disc photographs for glaucoma the european optic disc assessment trial 
773 1 8 |g volume:117  |g year:2010  |g number:4  |g month:01  |g pages:717-723  |g extent:7  |a Clinical assessment of stereoscopic optic disc photographs for glaucoma the european optic disc assessment trial 
856 4 0 |u https://doi.org/10.1016/j.ophtha.2009.09.026  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0161642009010914  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230515 
993 |a Article 
994 |a 2010 
998 |g 1028286732  |a Jonas, Jost B.  |m 1028286732:Jonas, Jost B.  |d 60000  |e 60000PJ1028286732  |k 0/60000/  |p 10 
999 |a KXP-PPN1845381610  |e 4321996074 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"recId":"320526941","part":{"text":"117(2010), 4 vom: Jan., Seite 717-723","year":"2010","issue":"4","volume":"117","pages":"717-723","extent":"7"},"id":{"eki":["320526941"],"issn":["1549-4713"],"zdb":["2015287-5"]},"pubHistory":["85.1978 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Amsterdam [u.a.] ; San Francisco, Calif.","dateIssuedKey":"1978","publisher":"Elsevier ; Acad.","dateIssuedDisp":"1978-"}],"corporate":[{"display":"American Academy of Ophthalmology","role":"isb"}],"title":[{"title":"Ophthalmology","title_sort":"Ophthalmology","subtitle":"journal of the American Academy of Ophthalmology"}],"note":["Gesehen am 15.01.20"],"disp":"Clinical assessment of stereoscopic optic disc photographs for glaucoma the european optic disc assessment trialOphthalmology"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1845381610","language":["eng"],"name":{"displayForm":["Nicolaas J. Reus, Hans G. Lemij, David F. Garway-Heath, P. Juhani Airaksinen, Alfonso Anton, Alain M. Bron, Christoph Faschinger, Gábor Holló, Michele Iester, Jost B. Jonas, Andrea Mistlberger, Fotis Topouzis, Thierry G. Zeyen"]},"physDesc":[{"extent":"7 S."}],"id":{"eki":["1845381610"],"doi":["10.1016/j.ophtha.2009.09.026"]},"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"4 January 2010"}],"title":[{"title_sort":"Clinical assessment of stereoscopic optic disc photographs for glaucoma","title":"Clinical assessment of stereoscopic optic disc photographs for glaucoma","subtitle":"the european optic disc assessment trial"}],"person":[{"given":"Nicolaas Johannes","role":"aut","family":"Reus","display":"Reus, Nicolaas Johannes"},{"display":"Lemij, Hans G.","role":"aut","given":"Hans G.","family":"Lemij"},{"role":"aut","given":"David F.","family":"Garway-Heath","display":"Garway-Heath, David F."},{"display":"Airaksinen, P. Juhani","role":"aut","given":"P. Juhani","family":"Airaksinen"},{"display":"Anton, Alfonso","family":"Anton","role":"aut","given":"Alfonso"},{"display":"Bron, Alain M.","given":"Alain M.","role":"aut","family":"Bron"},{"display":"Faschinger, Christoph","given":"Christoph","role":"aut","family":"Faschinger"},{"family":"Holló","role":"aut","given":"Gábor","display":"Holló, Gábor"},{"role":"aut","given":"Michele","family":"Iester","display":"Iester, Michele"},{"family":"Jonas","given":"Jost B.","role":"aut","display":"Jonas, Jost B."},{"given":"Andrea","role":"aut","family":"Mistlberger","display":"Mistlberger, Andrea"},{"display":"Topouzis, Fotis","family":"Topouzis","role":"aut","given":"Fotis"},{"family":"Zeyen","given":"Thierry G.","role":"aut","display":"Zeyen, Thierry G."}],"note":["Gesehen am 15.05.2023"]} 
SRT |a REUSNICOLACLINICALAS4201