The PETcoil project: PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI

Objective. We are developing a portable, ‘RF-penetrable’, brain-dedicated time of flight (TOF)-PET insert (PETcoil) for simultaneous PET/MRI. Approach. In this paper, we evaluate the PET performance of two fully assembled detector modules for this insert design outside the MR room. Main results. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dong, Qian (VerfasserIn) , Chang, Chen-Ming (VerfasserIn) , Lee, Brian J. (VerfasserIn) , Sacco, Ilaria (VerfasserIn) , Sajedi, Salar (VerfasserIn) , Adams, Zander (VerfasserIn) , Fischer, Peter (VerfasserIn) , Levin, Craig S. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 5 April 2023
In: Physics in medicine and biology
Year: 2023, Jahrgang: 68, Heft: 8, Pages: 1-15
ISSN:1361-6560
DOI:10.1088/1361-6560/acc3f2
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/acc3f2
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/1361-6560/acc3f2
Volltext
Verfasserangaben:Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin

MARC

LEADER 00000caa a2200000 c 4500
001 1846115744
003 DE-627
005 20230706205421.0
007 cr uuu---uuuuu
008 230524s2023 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/acc3f2  |2 doi 
035 |a (DE-627)1846115744 
035 |a (DE-599)KXP1846115744 
035 |a (OCoLC)1389529915 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 28  |2 sdnb 
100 1 |a Dong, Qian  |e VerfasserIn  |0 (DE-588)129045650X  |0 (DE-627)1846116422  |4 aut 
245 1 4 |a The PETcoil project  |b PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI  |c Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin 
264 1 |c 5 April 2023 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.05.2023 
520 |a Objective. We are developing a portable, ‘RF-penetrable’, brain-dedicated time of flight (TOF)-PET insert (PETcoil) for simultaneous PET/MRI. Approach. In this paper, we evaluate the PET performance of two fully assembled detector modules for this insert design outside the MR room. Main results. The global coincidence time resolution, global 511 keV energy resolution, coincidence count rate, and detector temperature achieved over 2 h data collection were 242.2 ± 0.4 ps full width at half maximum (FWHM), 11.19% ± 0.02% FWHM, 22.0 ± 0.1 kcps, and 23.5 °C ± 0.3 °C, respectively. The intrinsic spatial resolutions in the axial and transaxial directions were 2.74 ± 0.01 mm FWHM and 2.88 ± 0.03 mm FWHM, respectively. Significance. These results demonstrate excellent TOF capability and the performance and stability necessary for scaling up to a full ring comprising 16 detector modules. 
700 1 |a Chang, Chen-Ming  |e VerfasserIn  |4 aut 
700 1 |a Lee, Brian J.  |e VerfasserIn  |4 aut 
700 1 |a Sacco, Ilaria  |e VerfasserIn  |4 aut 
700 1 |a Sajedi, Salar  |e VerfasserIn  |4 aut 
700 1 |a Adams, Zander  |e VerfasserIn  |4 aut 
700 1 |a Fischer, Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)130634468  |0 (DE-627)707540682  |0 (DE-576)301221553  |4 aut 
700 1 |a Levin, Craig S.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 68(2023), 8 vom: Apr., Artikel-ID 085010, Seite 1-15  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI 
773 1 8 |g volume:68  |g year:2023  |g number:8  |g month:04  |g elocationid:085010  |g pages:1-15  |g extent:15  |a The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI 
856 4 0 |u https://doi.org/10.1088/1361-6560/acc3f2  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/acc3f2  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230524 
993 |a Article 
994 |a 2023 
998 |g 130634468  |a Fischer, Peter  |m 130634468:Fischer, Peter  |d 700000  |d 720000  |e 700000PF130634468  |e 720000PF130634468  |k 0/700000/  |k 1/700000/720000/  |p 7 
999 |a KXP-PPN1846115744  |e 432501859X 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"15 S."}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"5 April 2023"}],"relHost":[{"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology"}],"recId":"269016163","pubHistory":["1.1956 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"origin":[{"publisherPlace":"Bristol","publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-"}],"physDesc":[{"extent":"Online-Ressource"}],"disp":"The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRIPhysics in medicine and biology","note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"part":{"pages":"1-15","text":"68(2023), 8 vom: Apr., Artikel-ID 085010, Seite 1-15","extent":"15","issue":"8","volume":"68","year":"2023"}}],"recId":"1846115744","title":[{"title_sort":"PETcoil project","subtitle":"PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI","title":"The PETcoil project"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"id":{"eki":["1846115744"],"doi":["10.1088/1361-6560/acc3f2"]},"person":[{"display":"Dong, Qian","role":"aut","roleDisplay":"VerfasserIn","given":"Qian","family":"Dong"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Chang, Chen-Ming","given":"Chen-Ming","family":"Chang"},{"family":"Lee","given":"Brian J.","display":"Lee, Brian J.","role":"aut","roleDisplay":"VerfasserIn"},{"family":"Sacco","role":"aut","roleDisplay":"VerfasserIn","display":"Sacco, Ilaria","given":"Ilaria"},{"given":"Salar","roleDisplay":"VerfasserIn","role":"aut","display":"Sajedi, Salar","family":"Sajedi"},{"given":"Zander","roleDisplay":"VerfasserIn","role":"aut","display":"Adams, Zander","family":"Adams"},{"given":"Peter","display":"Fischer, Peter","role":"aut","roleDisplay":"VerfasserIn","family":"Fischer"},{"family":"Levin","given":"Craig S.","roleDisplay":"VerfasserIn","role":"aut","display":"Levin, Craig S."}],"note":["Gesehen am 24.05.2023"],"name":{"displayForm":["Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin"]}} 
SRT |a DONGQIANCHPETCOILPRO5202