The PETcoil project: PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI
Objective. We are developing a portable, ‘RF-penetrable’, brain-dedicated time of flight (TOF)-PET insert (PETcoil) for simultaneous PET/MRI. Approach. In this paper, we evaluate the PET performance of two fully assembled detector modules for this insert design outside the MR room. Main results. The...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
5 April 2023
|
| In: |
Physics in medicine and biology
Year: 2023, Jahrgang: 68, Heft: 8, Pages: 1-15 |
| ISSN: | 1361-6560 |
| DOI: | 10.1088/1361-6560/acc3f2 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/acc3f2 Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/1361-6560/acc3f2 |
| Verfasserangaben: | Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1846115744 | ||
| 003 | DE-627 | ||
| 005 | 20230706205421.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230524s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1088/1361-6560/acc3f2 |2 doi | |
| 035 | |a (DE-627)1846115744 | ||
| 035 | |a (DE-599)KXP1846115744 | ||
| 035 | |a (OCoLC)1389529915 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 28 |2 sdnb | ||
| 100 | 1 | |a Dong, Qian |e VerfasserIn |0 (DE-588)129045650X |0 (DE-627)1846116422 |4 aut | |
| 245 | 1 | 4 | |a The PETcoil project |b PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI |c Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin |
| 264 | 1 | |c 5 April 2023 | |
| 300 | |a 15 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 24.05.2023 | ||
| 520 | |a Objective. We are developing a portable, ‘RF-penetrable’, brain-dedicated time of flight (TOF)-PET insert (PETcoil) for simultaneous PET/MRI. Approach. In this paper, we evaluate the PET performance of two fully assembled detector modules for this insert design outside the MR room. Main results. The global coincidence time resolution, global 511 keV energy resolution, coincidence count rate, and detector temperature achieved over 2 h data collection were 242.2 ± 0.4 ps full width at half maximum (FWHM), 11.19% ± 0.02% FWHM, 22.0 ± 0.1 kcps, and 23.5 °C ± 0.3 °C, respectively. The intrinsic spatial resolutions in the axial and transaxial directions were 2.74 ± 0.01 mm FWHM and 2.88 ± 0.03 mm FWHM, respectively. Significance. These results demonstrate excellent TOF capability and the performance and stability necessary for scaling up to a full ring comprising 16 detector modules. | ||
| 700 | 1 | |a Chang, Chen-Ming |e VerfasserIn |4 aut | |
| 700 | 1 | |a Lee, Brian J. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Sacco, Ilaria |e VerfasserIn |4 aut | |
| 700 | 1 | |a Sajedi, Salar |e VerfasserIn |4 aut | |
| 700 | 1 | |a Adams, Zander |e VerfasserIn |4 aut | |
| 700 | 1 | |a Fischer, Peter |d 1961- |e VerfasserIn |0 (DE-588)130634468 |0 (DE-627)707540682 |0 (DE-576)301221553 |4 aut | |
| 700 | 1 | |a Levin, Craig S. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physics in medicine and biology |d Bristol : IOP Publ., 1956 |g 68(2023), 8 vom: Apr., Artikel-ID 085010, Seite 1-15 |h Online-Ressource |w (DE-627)269016163 |w (DE-600)1473501-5 |w (DE-576)088704130 |x 1361-6560 |7 nnas |a The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI |
| 773 | 1 | 8 | |g volume:68 |g year:2023 |g number:8 |g month:04 |g elocationid:085010 |g pages:1-15 |g extent:15 |a The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI |
| 856 | 4 | 0 | |u https://doi.org/10.1088/1361-6560/acc3f2 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://dx.doi.org/10.1088/1361-6560/acc3f2 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230524 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 130634468 |a Fischer, Peter |m 130634468:Fischer, Peter |d 700000 |d 720000 |e 700000PF130634468 |e 720000PF130634468 |k 0/700000/ |k 1/700000/720000/ |p 7 | ||
| 999 | |a KXP-PPN1846115744 |e 432501859X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"15 S."}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"5 April 2023"}],"relHost":[{"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology"}],"recId":"269016163","pubHistory":["1.1956 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"origin":[{"publisherPlace":"Bristol","publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-"}],"physDesc":[{"extent":"Online-Ressource"}],"disp":"The PETcoil project PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRIPhysics in medicine and biology","note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"part":{"pages":"1-15","text":"68(2023), 8 vom: Apr., Artikel-ID 085010, Seite 1-15","extent":"15","issue":"8","volume":"68","year":"2023"}}],"recId":"1846115744","title":[{"title_sort":"PETcoil project","subtitle":"PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI","title":"The PETcoil project"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"id":{"eki":["1846115744"],"doi":["10.1088/1361-6560/acc3f2"]},"person":[{"display":"Dong, Qian","role":"aut","roleDisplay":"VerfasserIn","given":"Qian","family":"Dong"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Chang, Chen-Ming","given":"Chen-Ming","family":"Chang"},{"family":"Lee","given":"Brian J.","display":"Lee, Brian J.","role":"aut","roleDisplay":"VerfasserIn"},{"family":"Sacco","role":"aut","roleDisplay":"VerfasserIn","display":"Sacco, Ilaria","given":"Ilaria"},{"given":"Salar","roleDisplay":"VerfasserIn","role":"aut","display":"Sajedi, Salar","family":"Sajedi"},{"given":"Zander","roleDisplay":"VerfasserIn","role":"aut","display":"Adams, Zander","family":"Adams"},{"given":"Peter","display":"Fischer, Peter","role":"aut","roleDisplay":"VerfasserIn","family":"Fischer"},{"family":"Levin","given":"Craig S.","roleDisplay":"VerfasserIn","role":"aut","display":"Levin, Craig S."}],"note":["Gesehen am 24.05.2023"],"name":{"displayForm":["Qian Dong, Chen-Ming Chang, Brian J Lee, Ilaria Sacco, Salar Sajedi, Zander Adams, Peter Fischer and Craig S Levin"]}} | ||
| SRT | |a DONGQIANCHPETCOILPRO5202 | ||