Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods: evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten
<p> <b>Purpose</b> The goal of this study was to evaluate the diagnostic accuracy of perfusion computed tomography (CT) parameters obtained by different mathematical-kinetic methods for distinguishing pancreatic adenocarcinoma from normal tissue. To determine cut-off values and to...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
26. März 2021
|
| In: |
RöFo
Year: 2021, Volume: 193, Issue: 9, Pages: 1062-1073 |
| ISSN: | 1438-9010 |
| DOI: | 10.1055/a-1401-0333 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1055/a-1401-0333 Verlag, lizenzpflichtig, Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/a-1401-0333 |
| Author Notes: | authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1846210755 | ||
| 003 | DE-627 | ||
| 005 | 20230707004836.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230525s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1055/a-1401-0333 |2 doi | |
| 035 | |a (DE-627)1846210755 | ||
| 035 | |a (DE-599)KXP1846210755 | ||
| 035 | |a (OCoLC)1389537817 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Koell, Marco |d 1988- |e VerfasserIn |0 (DE-588)1183119372 |0 (DE-627)166304211X |4 aut | |
| 245 | 1 | 0 | |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods |b evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten |c authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher |
| 246 | 3 | 1 | |a Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode |b Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten |
| 264 | 1 | |c 26. März 2021 | |
| 300 | |a 12 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 25.05.2023 | ||
| 520 | |a <p> <b>Purpose</b> The goal of this study was to evaluate the diagnostic accuracy of perfusion computed tomography (CT) parameters obtained by different mathematical-kinetic methods for distinguishing pancreatic adenocarcinoma from normal tissue. To determine cut-off values and to assess the interchangeability of cut-off values, which were determined by different methods.</p> <p> <b>Materials and Methods</b> Perfusion CT imaging of the pancreas was prospectively performed in 23 patients. 19 patients with histopathologically confirmed pancreatic adenocarcinoma were included in the study. Blood flow (BF), blood volume (BV) and permeability-surface area product (PS) were measured in pancreatic adenocarcinoma and normal tissue with the deconvolution (BF, BV, PS), maximum slope (BF), and Patlak methods (BV, PS). The interchangeability of cut-off values was examined by assessing agreement between BF, BV, and PS measured with different mathematical-kinetic methods.</p> <p> <b>Results</b> Bland-Altman analysis demonstrated poor agreement between perfusion parameters, measured with different mathematical-kinetic methods. According to receiver operating characteristic (ROC) analysis, PS measured with the Patlak method had the significantly lowest diagnostic accuracy (area under ROC curve = 0.748). All other parameters were of high diagnostic accuracy (area under ROC curve = 0.940-0.997), although differences in diagnostic accuracy were not statistically different. Cut-off values for BF of ≤ 91.83 ml/100 ml/min and for BV of ≤ 5.36 ml/100 ml, both measured with the deconvolution method, appear to be the most appropriate cut-off values to distinguish pancreatic adenocarcinoma from normal tissue.</p> <p> <b>Conclusion</b> Perfusion parameters obtained by different methods are not interchangeable. Therefore, cut-off values, which were determined using different methods, are not interchangeable either. Perfusion parameters can help to distinguish pancreatic adenocarcinoma from normal tissue with high diagnostic accuracy, except for PS measured with the Patlak method.</p> <p> <b>Key Points:</b> </p> <p> <b>Citation Format</b> </p> | ||
| 700 | 1 | |a Klauß, Miriam |d 1978- |e VerfasserIn |0 (DE-588)130870552 |0 (DE-627)506783839 |0 (DE-576)29838728X |4 aut | |
| 700 | 1 | |a Skornitzke, Stephan |d 1987- |e VerfasserIn |0 (DE-588)1110072589 |0 (DE-627)864783523 |0 (DE-576)475718267 |4 aut | |
| 700 | 1 | |a Mayer, Philipp |d 1985- |e VerfasserIn |0 (DE-588)1066605440 |0 (DE-627)817714758 |0 (DE-576)426052250 |4 aut | |
| 700 | 1 | |a Fritz, Franziska |d 1986- |e VerfasserIn |0 (DE-588)1041966393 |0 (DE-627)768050987 |0 (DE-576)393612600 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 700 | 1 | |a Grenacher, Lars |d 1967- |e VerfasserIn |0 (DE-588)115424598 |0 (DE-627)691308977 |0 (DE-576)289876761 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t RöFo |d Stuttgart [u.a.] : Thieme, 1975 |g 193(2021), 9 vom: März, Seite 1062-1073 |h Online-Ressource |w (DE-627)324825021 |w (DE-600)2031079-1 |w (DE-576)107736748 |x 1438-9010 |7 nnas |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten |
| 773 | 1 | 8 | |g volume:193 |g year:2021 |g number:9 |g month:03 |g pages:1062-1073 |g extent:12 |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten |
| 856 | 4 | 0 | |u https://doi.org/10.1055/a-1401-0333 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.thieme-connect.de/DOI/DOI?10.1055/a-1401-0333 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230525 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 115424598 |a Grenacher, Lars |m 115424598:Grenacher, Lars |d 50000 |e 50000PG115424598 |k 0/50000/ |p 7 |y j | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |d 50000 |e 910000PS105822672X |e 911400PS105822672X |e 50000PS105822672X |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 6 | ||
| 998 | |g 1041966393 |a Fritz, Franziska |m 1041966393:Fritz, Franziska |d 50000 |e 50000PF1041966393 |k 0/50000/ |p 5 | ||
| 998 | |g 1066605440 |a Mayer, Philipp |m 1066605440:Mayer, Philipp |d 910000 |d 911400 |e 910000PM1066605440 |e 911400PM1066605440 |k 0/910000/ |k 1/910000/911400/ |p 4 | ||
| 998 | |g 1110072589 |a Skornitzke, Stephan |m 1110072589:Skornitzke, Stephan |d 910000 |d 911400 |e 910000PS1110072589 |e 911400PS1110072589 |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 130870552 |a Klauß, Miriam |m 130870552:Klauß, Miriam |d 910000 |d 911400 |d 50000 |e 910000PK130870552 |e 911400PK130870552 |e 50000PK130870552 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 2 | ||
| 998 | |g 1183119372 |a Koell, Marco |m 1183119372:Koell, Marco |d 50000 |e 50000PK1183119372 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1846210755 |e 4325170782 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Thieme","dateIssuedDisp":"1975-","dateIssuedKey":"1975","publisherPlace":"Stuttgart [u.a.]"}],"language":["ger"],"disp":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-WertenRöFo","title":[{"title":"RöFo","title_sort":"RöFo","subtitle":"Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren"}],"pubHistory":["122.1975 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 20.03.2023"],"recId":"324825021","part":{"issue":"9","volume":"193","year":"2021","extent":"12","pages":"1062-1073","text":"193(2021), 9 vom: März, Seite 1062-1073"},"id":{"doi":["10.1055/s-00000066"],"issn":["1438-9010"],"eki":["324825021"],"zdb":["2031079-1"]},"titleAlt":[{"title":"RöFo vereinigt mit Aktuelle Radiologie"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der neuen bildgebenden Verfahren"}]}],"id":{"doi":["10.1055/a-1401-0333"],"eki":["1846210755"]},"name":{"displayForm":["authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher"]},"physDesc":[{"extent":"12 S."}],"origin":[{"dateIssuedDisp":"26. März 2021","dateIssuedKey":"2021"}],"language":["eng"],"person":[{"family":"Koell","given":"Marco","role":"aut","roleDisplay":"VerfasserIn","display":"Koell, Marco"},{"family":"Klauß","display":"Klauß, Miriam","roleDisplay":"VerfasserIn","role":"aut","given":"Miriam"},{"given":"Stephan","roleDisplay":"VerfasserIn","role":"aut","display":"Skornitzke, Stephan","family":"Skornitzke"},{"display":"Mayer, Philipp","given":"Philipp","roleDisplay":"VerfasserIn","role":"aut","family":"Mayer"},{"given":"Franziska","roleDisplay":"VerfasserIn","role":"aut","display":"Fritz, Franziska","family":"Fritz"},{"family":"Stiller","display":"Stiller, Wolfram","given":"Wolfram","role":"aut","roleDisplay":"VerfasserIn"},{"display":"Grenacher, Lars","roleDisplay":"VerfasserIn","role":"aut","given":"Lars","family":"Grenacher"}],"title":[{"title_sort":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods","title":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods","subtitle":"evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten"}],"titleTranslated":[{"translated":"Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1846210755","note":["Gesehen am 25.05.2023"]} | ||
| SRT | |a KOELLMARCOCOMPUTEDTO2620 | ||