Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods: evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten

<p> <b>Purpose</b> The goal of this study was to evaluate the diagnostic accuracy of perfusion computed tomography (CT) parameters obtained by different mathematical-kinetic methods for distinguishing pancreatic adenocarcinoma from normal tissue. To determine cut-off values and to...

Full description

Saved in:
Bibliographic Details
Main Authors: Koell, Marco (Author) , Klauß, Miriam (Author) , Skornitzke, Stephan (Author) , Mayer, Philipp (Author) , Fritz, Franziska (Author) , Stiller, Wolfram (Author) , Grenacher, Lars (Author)
Format: Article (Journal)
Language:English
Published: 26. März 2021
In: RöFo
Year: 2021, Volume: 193, Issue: 9, Pages: 1062-1073
ISSN:1438-9010
DOI:10.1055/a-1401-0333
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1055/a-1401-0333
Verlag, lizenzpflichtig, Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/a-1401-0333
Get full text
Author Notes:authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher

MARC

LEADER 00000caa a2200000 c 4500
001 1846210755
003 DE-627
005 20230707004836.0
007 cr uuu---uuuuu
008 230525s2021 xx |||||o 00| ||eng c
024 7 |a 10.1055/a-1401-0333  |2 doi 
035 |a (DE-627)1846210755 
035 |a (DE-599)KXP1846210755 
035 |a (OCoLC)1389537817 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Koell, Marco  |d 1988-  |e VerfasserIn  |0 (DE-588)1183119372  |0 (DE-627)166304211X  |4 aut 
245 1 0 |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods  |b evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten  |c authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher 
246 3 1 |a Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode  |b Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten 
264 1 |c 26. März 2021 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.05.2023 
520 |a <p> <b>Purpose</b> The goal of this study was to evaluate the diagnostic accuracy of perfusion computed tomography (CT) parameters obtained by different mathematical-kinetic methods for distinguishing pancreatic adenocarcinoma from normal tissue. To determine cut-off values and to assess the interchangeability of cut-off values, which were determined by different methods.</p> <p> <b>Materials and Methods</b> Perfusion CT imaging of the pancreas was prospectively performed in 23 patients. 19 patients with histopathologically confirmed pancreatic adenocarcinoma were included in the study. Blood flow (BF), blood volume (BV) and permeability-surface area product (PS) were measured in pancreatic adenocarcinoma and normal tissue with the deconvolution (BF, BV, PS), maximum slope (BF), and Patlak methods (BV, PS). The interchangeability of cut-off values was examined by assessing agreement between BF, BV, and PS measured with different mathematical-kinetic methods.</p> <p> <b>Results</b> Bland-Altman analysis demonstrated poor agreement between perfusion parameters, measured with different mathematical-kinetic methods. According to receiver operating characteristic (ROC) analysis, PS measured with the Patlak method had the significantly lowest diagnostic accuracy (area under ROC curve = 0.748). All other parameters were of high diagnostic accuracy (area under ROC curve = 0.940-0.997), although differences in diagnostic accuracy were not statistically different. Cut-off values for BF of ≤ 91.83 ml/100 ml/min and for BV of ≤ 5.36 ml/100 ml, both measured with the deconvolution method, appear to be the most appropriate cut-off values to distinguish pancreatic adenocarcinoma from normal tissue.</p> <p> <b>Conclusion</b> Perfusion parameters obtained by different methods are not interchangeable. Therefore, cut-off values, which were determined using different methods, are not interchangeable either. Perfusion parameters can help to distinguish pancreatic adenocarcinoma from normal tissue with high diagnostic accuracy, except for PS measured with the Patlak method.</p> <p> <b>Key Points:</b> </p> <p> <b>Citation Format</b> </p> 
700 1 |a Klauß, Miriam  |d 1978-  |e VerfasserIn  |0 (DE-588)130870552  |0 (DE-627)506783839  |0 (DE-576)29838728X  |4 aut 
700 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
700 1 |a Mayer, Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1066605440  |0 (DE-627)817714758  |0 (DE-576)426052250  |4 aut 
700 1 |a Fritz, Franziska  |d 1986-  |e VerfasserIn  |0 (DE-588)1041966393  |0 (DE-627)768050987  |0 (DE-576)393612600  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
700 1 |a Grenacher, Lars  |d 1967-  |e VerfasserIn  |0 (DE-588)115424598  |0 (DE-627)691308977  |0 (DE-576)289876761  |4 aut 
773 0 8 |i Enthalten in  |t RöFo  |d Stuttgart [u.a.] : Thieme, 1975  |g 193(2021), 9 vom: März, Seite 1062-1073  |h Online-Ressource  |w (DE-627)324825021  |w (DE-600)2031079-1  |w (DE-576)107736748  |x 1438-9010  |7 nnas  |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten 
773 1 8 |g volume:193  |g year:2021  |g number:9  |g month:03  |g pages:1062-1073  |g extent:12  |a Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten 
856 4 0 |u https://doi.org/10.1055/a-1401-0333  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.thieme-connect.de/DOI/DOI?10.1055/a-1401-0333  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230525 
993 |a Article 
994 |a 2021 
998 |g 115424598  |a Grenacher, Lars  |m 115424598:Grenacher, Lars  |d 50000  |e 50000PG115424598  |k 0/50000/  |p 7  |y j 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |d 50000  |e 910000PS105822672X  |e 911400PS105822672X  |e 50000PS105822672X  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 6 
998 |g 1041966393  |a Fritz, Franziska  |m 1041966393:Fritz, Franziska  |d 50000  |e 50000PF1041966393  |k 0/50000/  |p 5 
998 |g 1066605440  |a Mayer, Philipp  |m 1066605440:Mayer, Philipp  |d 910000  |d 911400  |e 910000PM1066605440  |e 911400PM1066605440  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 910000  |d 911400  |e 910000PS1110072589  |e 911400PS1110072589  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 130870552  |a Klauß, Miriam  |m 130870552:Klauß, Miriam  |d 910000  |d 911400  |d 50000  |e 910000PK130870552  |e 911400PK130870552  |e 50000PK130870552  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 2 
998 |g 1183119372  |a Koell, Marco  |m 1183119372:Koell, Marco  |d 50000  |e 50000PK1183119372  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1846210755  |e 4325170782 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Thieme","dateIssuedDisp":"1975-","dateIssuedKey":"1975","publisherPlace":"Stuttgart [u.a.]"}],"language":["ger"],"disp":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-WertenRöFo","title":[{"title":"RöFo","title_sort":"RöFo","subtitle":"Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren"}],"pubHistory":["122.1975 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 20.03.2023"],"recId":"324825021","part":{"issue":"9","volume":"193","year":"2021","extent":"12","pages":"1062-1073","text":"193(2021), 9 vom: März, Seite 1062-1073"},"id":{"doi":["10.1055/s-00000066"],"issn":["1438-9010"],"eki":["324825021"],"zdb":["2031079-1"]},"titleAlt":[{"title":"RöFo vereinigt mit Aktuelle Radiologie"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der neuen bildgebenden Verfahren"}]}],"id":{"doi":["10.1055/a-1401-0333"],"eki":["1846210755"]},"name":{"displayForm":["authors Marco Koell, Miriam Klauss, Stephan Skornitzke, Philipp Mayer, Franziska Fritz, Wolfram Stiller, Lars Grenacher"]},"physDesc":[{"extent":"12 S."}],"origin":[{"dateIssuedDisp":"26. März 2021","dateIssuedKey":"2021"}],"language":["eng"],"person":[{"family":"Koell","given":"Marco","role":"aut","roleDisplay":"VerfasserIn","display":"Koell, Marco"},{"family":"Klauß","display":"Klauß, Miriam","roleDisplay":"VerfasserIn","role":"aut","given":"Miriam"},{"given":"Stephan","roleDisplay":"VerfasserIn","role":"aut","display":"Skornitzke, Stephan","family":"Skornitzke"},{"display":"Mayer, Philipp","given":"Philipp","roleDisplay":"VerfasserIn","role":"aut","family":"Mayer"},{"given":"Franziska","roleDisplay":"VerfasserIn","role":"aut","display":"Fritz, Franziska","family":"Fritz"},{"family":"Stiller","display":"Stiller, Wolfram","given":"Wolfram","role":"aut","roleDisplay":"VerfasserIn"},{"display":"Grenacher, Lars","roleDisplay":"VerfasserIn","role":"aut","given":"Lars","family":"Grenacher"}],"title":[{"title_sort":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods","title":"Computed tomography perfusion analysis of pancreatic adenocarcinoma using deconvolution, maximum slope, and Patlak methods","subtitle":"evaluation of diagnostic accuracy and interchangeability of cut-off values = Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode : Evaluation der diagnostischen Güte und Austauschbarkeit von Cut-off-Werten"}],"titleTranslated":[{"translated":"Computertomografische Perfusionsanalyse des Pankreaskarzinoms mit der Deconvolution-, Maximum-Slope- und Patlak-Methode"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1846210755","note":["Gesehen am 25.05.2023"]} 
SRT |a KOELLMARCOCOMPUTEDTO2620