The FRESH study: treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patients

BACKGROUND AND PURPOSE: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. - MATERIALS AND METHODS: Medical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Vollherbst, Dominik (VerfasserIn) , Lücking, H. (VerfasserIn) , DuPlessis, J. (VerfasserIn) , Sonnberger, M. (VerfasserIn) , Maurer, C. (VerfasserIn) , Kocer, N. (VerfasserIn) , Killer-Oberpfalzer, M. (VerfasserIn) , Rautio, R. (VerfasserIn) , Valvassori, L. (VerfasserIn) , Berlis, A. (VerfasserIn) , Gasser, S. (VerfasserIn) , Gatt, S. (VerfasserIn) , Dörfler, A. (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Möhlenbruch, Markus Alfred (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: April 10, 2023
In: American journal of neuroradiology
Year: 2023, Jahrgang: 44, Heft: 4, Pages: 474-480
ISSN:1936-959X
DOI:10.3174/ajnr.A7834
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3174/ajnr.A7834
Verlag, lizenzpflichtig, Volltext: https://www.ajnr.org/content/44/4/474
Volltext
Verfasserangaben:D.F. Vollherbst, H. Lücking, J. DuPlessis, M. Sonnberger, C. Maurer, N. Kocer, M. Killer-Oberpfalzer, R. Rautio, L. Valvassori, A. Berlis, S. Gasser, S. Gatt, A. Dörfler, M. Bendszus, and M.A. Möhlenbruch

MARC

LEADER 00000caa a2200000 c 4500
001 1847476635
003 DE-627
005 20230706204811.0
007 cr uuu---uuuuu
008 230606s2023 xx |||||o 00| ||eng c
024 7 |a 10.3174/ajnr.A7834  |2 doi 
035 |a (DE-627)1847476635 
035 |a (DE-599)KXP1847476635 
035 |a (OCoLC)1389529876 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Vollherbst, Dominik  |d 1989-  |e VerfasserIn  |0 (DE-588)1071379569  |0 (DE-627)825819024  |0 (DE-576)407878866  |4 aut 
245 1 4 |a The FRESH study  |b treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patients  |c D.F. Vollherbst, H. Lücking, J. DuPlessis, M. Sonnberger, C. Maurer, N. Kocer, M. Killer-Oberpfalzer, R. Rautio, L. Valvassori, A. Berlis, S. Gasser, S. Gatt, A. Dörfler, M. Bendszus, and M.A. Möhlenbruch 
264 1 |c April 10, 2023 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.06.2023 
520 |a BACKGROUND AND PURPOSE: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. - MATERIALS AND METHODS: Medical charts and procedural and imaging data of a consecutive series of patients with intracranial aneurysms who were treated with the FRED X at 9 international neurovascular centers were retrospectively analyzed. - RESULTS: One hundred sixty-one patients (77.6% women; mean age, 55 years) with 184 aneurysms (11.2% acutely ruptured) were included in this study. Most aneurysms were located in the anterior circulation (77.0%), most frequently at the ICA (72.7%). The FRED X was successfully implanted in all procedures. Additional coiling was performed in 29.8%. In-stent balloon angioplasty was necessary in 2.5%. The rate of major adverse events was 3.1%. Thrombotic events occurred in 7 patients (4.3%) with 4 intra- and 4 postprocedural in-stent thromboses, respectively (1 patient had both peri- and postprocedural thrombosis). Of these thrombotic events, only 2 (1.2%) led to major adverse events (ischemic strokes). Postinterventional neurologic morbidity and mortality were observed in 1.9% and 1.2%, respectively. The rate of complete aneurysm occlusion after a mean follow-up of 7.0 months was 66.0%. - CONCLUSIONS: The new FRED X is a safe and feasible device for aneurysm treatment. In this retrospective multicenter study, the rate of thrombotic complications was low, and the short-term occlusion rates are satisfactory. 
700 1 |a Lücking, H.  |e VerfasserIn  |4 aut 
700 1 |a DuPlessis, J.  |e VerfasserIn  |4 aut 
700 1 |a Sonnberger, M.  |e VerfasserIn  |4 aut 
700 1 |a Maurer, C.  |e VerfasserIn  |4 aut 
700 1 |a Kocer, N.  |e VerfasserIn  |4 aut 
700 1 |a Killer-Oberpfalzer, M.  |e VerfasserIn  |4 aut 
700 1 |a Rautio, R.  |e VerfasserIn  |4 aut 
700 1 |a Valvassori, L.  |e VerfasserIn  |4 aut 
700 1 |a Berlis, A.  |e VerfasserIn  |4 aut 
700 1 |a Gasser, S.  |e VerfasserIn  |4 aut 
700 1 |a Gatt, S.  |e VerfasserIn  |4 aut 
700 1 |a Dörfler, A.  |e VerfasserIn  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Möhlenbruch, Markus Alfred  |d 1979-  |e VerfasserIn  |0 (DE-588)137693591  |0 (DE-627)594845041  |0 (DE-576)304845655  |4 aut 
773 0 8 |i Enthalten in  |t American journal of neuroradiology  |d Oak Brook, Ill. : Soc., 1980  |g 44(2023), 4 vom: Apr., Seite 474-480  |h Online-Ressource  |w (DE-627)320647331  |w (DE-600)2025541-X  |w (DE-576)101556217  |x 1936-959X  |7 nnas  |a The FRESH study treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patients 
773 1 8 |g volume:44  |g year:2023  |g number:4  |g month:04  |g pages:474-480  |g extent:7  |a The FRESH study treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patients 
856 4 0 |u https://doi.org/10.3174/ajnr.A7834  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ajnr.org/content/44/4/474  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230606 
993 |a Article 
994 |a 2023 
998 |g 137693591  |a Möhlenbruch, Markus Alfred  |m 137693591:Möhlenbruch, Markus Alfred  |d 910000  |d 911200  |d 50000  |e 910000PM137693591  |e 911200PM137693591  |e 50000PM137693591  |k 0/910000/  |k 1/910000/911200/  |k 0/50000/  |p 15  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911200  |e 910000PB1032676426  |e 911200PB1032676426  |k 0/910000/  |k 1/910000/911200/  |p 14 
998 |g 1071379569  |a Vollherbst, Dominik  |m 1071379569:Vollherbst, Dominik  |d 910000  |d 911200  |d 50000  |e 910000PV1071379569  |e 911200PV1071379569  |e 50000PV1071379569  |k 0/910000/  |k 1/910000/911200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1847476635  |e 4329580160 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["D.F. Vollherbst, H. Lücking, J. DuPlessis, M. Sonnberger, C. Maurer, N. Kocer, M. Killer-Oberpfalzer, R. Rautio, L. Valvassori, A. Berlis, S. Gasser, S. Gatt, A. Dörfler, M. Bendszus, and M.A. Möhlenbruch"]},"language":["eng"],"note":["Gesehen am 06.06.2023"],"person":[{"family":"Vollherbst","role":"aut","display":"Vollherbst, Dominik","given":"Dominik"},{"given":"H.","display":"Lücking, H.","role":"aut","family":"Lücking"},{"family":"DuPlessis","role":"aut","display":"DuPlessis, J.","given":"J."},{"given":"M.","display":"Sonnberger, M.","role":"aut","family":"Sonnberger"},{"display":"Maurer, C.","given":"C.","family":"Maurer","role":"aut"},{"display":"Kocer, N.","given":"N.","family":"Kocer","role":"aut"},{"given":"M.","display":"Killer-Oberpfalzer, M.","role":"aut","family":"Killer-Oberpfalzer"},{"family":"Rautio","role":"aut","given":"R.","display":"Rautio, R."},{"given":"L.","display":"Valvassori, L.","family":"Valvassori","role":"aut"},{"display":"Berlis, A.","given":"A.","role":"aut","family":"Berlis"},{"given":"S.","display":"Gasser, S.","family":"Gasser","role":"aut"},{"role":"aut","family":"Gatt","display":"Gatt, S.","given":"S."},{"display":"Dörfler, A.","given":"A.","role":"aut","family":"Dörfler"},{"family":"Bendszus","role":"aut","given":"Martin","display":"Bendszus, Martin"},{"display":"Möhlenbruch, Markus Alfred","given":"Markus Alfred","role":"aut","family":"Möhlenbruch"}],"recId":"1847476635","id":{"doi":["10.3174/ajnr.A7834"],"eki":["1847476635"]},"physDesc":[{"extent":"7 S."}],"title":[{"title":"The FRESH study","subtitle":"treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patients","title_sort":"FRESH study"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"April 10, 2023"}],"relHost":[{"titleAlt":[{"title":"AJNR"}],"disp":"The FRESH study treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology - first multicenter experience in 161 patientsAmerican journal of neuroradiology","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1980 -"],"note":["Gesehen am 31.01.25","Fortsetzung der Druck-Ausgabe"],"part":{"text":"44(2023), 4 vom: Apr., Seite 474-480","issue":"4","pages":"474-480","extent":"7","volume":"44","year":"2023"},"language":["eng"],"origin":[{"publisher":"Soc.","dateIssuedDisp":"1980-","dateIssuedKey":"1980","publisherPlace":"Oak Brook, Ill."}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2025541-X"],"issn":["1936-959X"],"eki":["320647331"]},"title":[{"subtitle":"AJNR","title":"American journal of neuroradiology","title_sort":"American journal of neuroradiology"}],"recId":"320647331","name":{"displayForm":["American Society of Neuroradiology"]}}]} 
SRT |a VOLLHERBSTFRESHSTUDY1020