Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model

Objective. We propose an integration scheme for a biomechanical motion model into a deformable image registration. We demonstrate its accuracy and reproducibility for adaptive radiation therapy in the head and neck region. Approach. The novel registration scheme for the bony structures in the head a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bauer, Cornelius Jonathan (VerfasserIn) , Teske, Hendrik (VerfasserIn) , Walter, Alexandra (VerfasserIn) , Hoegen-Saßmannshausen, Philipp (VerfasserIn) , Adeberg, Sebastian (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Giske, Kristina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 19 April 2023
In: Physics in medicine and biology
Year: 2023, Jahrgang: 68, Heft: 9, Pages: 1-12
ISSN:1361-6560
DOI:10.1088/1361-6560/acc7f1
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1088/1361-6560/acc7f1
Verlag, kostenfrei, Volltext: https://dx.doi.org/10.1088/1361-6560/acc7f1
Volltext
Verfasserangaben:Cornelius J. Bauer, Hendrik Teske, Alexandra Walter, Philipp Hoegen, Sebastian Adeberg, Jürgen Debus, Oliver Jäkel and Kristina Giske

MARC

LEADER 00000caa a2200000 c 4500
001 1848961634
003 DE-627
005 20230706203639.0
007 cr uuu---uuuuu
008 230614s2023 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/acc7f1  |2 doi 
035 |a (DE-627)1848961634 
035 |a (DE-599)KXP1848961634 
035 |a (OCoLC)1389528054 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bauer, Cornelius Jonathan  |d 1992-  |e VerfasserIn  |0 (DE-588)1289551057  |0 (DE-627)1845544358  |4 aut 
245 1 0 |a Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model  |c Cornelius J. Bauer, Hendrik Teske, Alexandra Walter, Philipp Hoegen, Sebastian Adeberg, Jürgen Debus, Oliver Jäkel and Kristina Giske 
264 1 |c 19 April 2023 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.06.2023 
520 |a Objective. We propose an integration scheme for a biomechanical motion model into a deformable image registration. We demonstrate its accuracy and reproducibility for adaptive radiation therapy in the head and neck region. Approach. The novel registration scheme for the bony structures in the head and neck regions is based on a previously developed articulated kinematic skeleton model. The realized iterative single-bone optimization process directly triggers posture changes of the articulated skeleton, exchanging the transformation model within the deformable image registration process. Accuracy in terms of target registration errors in the bones is evaluated for 18 vector fields of three patients between each planning CT and six fraction CT scans distributed along the treatment course. Main results. The median of target registration error distribution of the landmark pairs is 1.4 ± 0.3 mm. This is sufficient accuracy for adaptive radiation therapy. The registration performs equally well for all three patients and no degradation of the registration accuracy can be observed throughout the treatment. Significance. Deformable image registration, despite its known residual uncertainties, is until now the tool of choice towards online re-planning automation. By introducing a biofidelic motion model into the optimization, we provide a viable way towards an in-build quality assurance. 
700 1 |a Teske, Hendrik  |e VerfasserIn  |4 aut 
700 1 |a Walter, Alexandra  |e VerfasserIn  |4 aut 
700 1 |a Hoegen-Saßmannshausen, Philipp  |d 1987-  |e VerfasserIn  |0 (DE-588)1162715278  |0 (DE-627)1026887836  |0 (DE-576)507591283  |4 aut 
700 1 |a Adeberg, Sebastian  |d 1984-  |e VerfasserIn  |0 (DE-588)1049743377  |0 (DE-627)782574467  |0 (DE-576)403727774  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Giske, Kristina  |e VerfasserIn  |0 (DE-588)143742507  |0 (DE-627)654332177  |0 (DE-576)338673385  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 68(2023), 9 vom: Apr., Artikel-ID 095006, Seite 1-12  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model 
773 1 8 |g volume:68  |g year:2023  |g number:9  |g month:04  |g elocationid:095006  |g pages:1-12  |g extent:12  |a Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model 
856 4 0 |u https://doi.org/10.1088/1361-6560/acc7f1  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/acc7f1  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230614 
993 |a Article 
994 |a 2023 
998 |g 143742507  |a Giske, Kristina  |m 143742507:Giske, Kristina  |d 50000  |e 50000PG143742507  |k 0/50000/  |p 8  |y j 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 7 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1049743377  |a Adeberg, Sebastian  |m 1049743377:Adeberg, Sebastian  |d 50000  |e 50000PA1049743377  |k 0/50000/  |p 5 
998 |g 1162715278  |a Hoegen-Saßmannshausen, Philipp  |m 1162715278:Hoegen-Saßmannshausen, Philipp  |d 910000  |d 911400  |e 910000PH1162715278  |e 911400PH1162715278  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1289551057  |a Bauer, Cornelius Jonathan  |m 1289551057:Bauer, Cornelius Jonathan  |d 130000  |e 130000PB1289551057  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1848961634  |e 4336945314 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model","title_sort":"Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model"}],"note":["Gesehen am 14.06.2023"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Bauer","given":"Cornelius Jonathan","role":"aut","display":"Bauer, Cornelius Jonathan"},{"display":"Teske, Hendrik","family":"Teske","role":"aut","given":"Hendrik"},{"family":"Walter","given":"Alexandra","role":"aut","display":"Walter, Alexandra"},{"given":"Philipp","role":"aut","family":"Hoegen-Saßmannshausen","display":"Hoegen-Saßmannshausen, Philipp"},{"display":"Adeberg, Sebastian","role":"aut","given":"Sebastian","family":"Adeberg"},{"display":"Debus, Jürgen","given":"Jürgen","role":"aut","family":"Debus"},{"display":"Jäkel, Oliver","family":"Jäkel","given":"Oliver","role":"aut"},{"display":"Giske, Kristina","role":"aut","given":"Kristina","family":"Giske"}],"relHost":[{"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]},"title":[{"title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine"}],"part":{"year":"2023","volume":"68","pages":"1-12","extent":"12","text":"68(2023), 9 vom: Apr., Artikel-ID 095006, Seite 1-12","issue":"9"},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisherPlace":"Bristol","publisher":"IOP Publ."}],"pubHistory":["1.1956 -"],"disp":"Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation modelPhysics in medicine and biology","recId":"269016163","physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"19 April 2023"}],"recId":"1848961634","physDesc":[{"extent":"12 S."}],"id":{"eki":["1848961634"],"doi":["10.1088/1361-6560/acc7f1"]},"name":{"displayForm":["Cornelius J. Bauer, Hendrik Teske, Alexandra Walter, Philipp Hoegen, Sebastian Adeberg, Jürgen Debus, Oliver Jäkel and Kristina Giske"]}} 
SRT |a BAUERCORNEBIOFIDELIC1920