Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients: insights from the German DEVICE registry

Background - Because of its antiarrhythmic potency and due to the lack of alternatives, amiodarone is often used for antiarrhythmic therapy in patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator systems. To date, robust data on the safety and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wiedmann, Felix Tobias (VerfasserIn) , Ince, Hüseyin (VerfasserIn) , Stellbrink, Christoph (VerfasserIn) , Kleemann, Thomas (VerfasserIn) , Eckardt, Lars (VerfasserIn) , Brachmann, Johannes (VerfasserIn) , Gonska, Bernd-Dieter (VerfasserIn) , Kääb, Stefan (VerfasserIn) , Perings, Christian A. (VerfasserIn) , Jung, Werner (VerfasserIn) , Lugenbiel, Patrick (VerfasserIn) , Hochadel, Matthias (VerfasserIn) , Senges, Jochen (VerfasserIn) , Frey, Norbert (VerfasserIn) , Schmidt, Constanze (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 28 March 2023
In: Heart rhythm
Year: 2023, Jahrgang: 20, Heft: 4, Pages: 501-509
ISSN:1556-3871
DOI:10.1016/j.hrthm.2022.12.009
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.hrthm.2022.12.009
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1547527122026972
Volltext
Verfasserangaben:Felix Wiedmann, Hüseyin Ince, Christoph Stellbrink, Thomas Kleemann, Lars Eckardt, Johannes Brachmann, Bernd-Dieter Gonska, Stefan Kääb, Christian A. Perings, Werner Jung, Patrick Lugenbiel, Matthias Hochadel, Jochen Senges, Norbert Frey, Constanze Schmidt

MARC

LEADER 00000caa a2200000 c 4500
001 1849775273
003 DE-627
005 20241016130420.0
007 cr uuu---uuuuu
008 230615s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.hrthm.2022.12.009  |2 doi 
035 |a (DE-627)1849775273 
035 |a (DE-599)KXP1849775273 
035 |a (OCoLC)1389528173 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wiedmann, Felix Tobias  |d 1987-  |e VerfasserIn  |0 (DE-588)1055852441  |0 (DE-627)792733479  |0 (DE-576)411904159  |4 aut 
245 1 0 |a Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients  |b insights from the German DEVICE registry  |c Felix Wiedmann, Hüseyin Ince, Christoph Stellbrink, Thomas Kleemann, Lars Eckardt, Johannes Brachmann, Bernd-Dieter Gonska, Stefan Kääb, Christian A. Perings, Werner Jung, Patrick Lugenbiel, Matthias Hochadel, Jochen Senges, Norbert Frey, Constanze Schmidt 
264 1 |c 28 March 2023 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 10. Dezember 2022, Artikelversion 28. März 2023 
500 |a Gesehen am 15.06.2023 
520 |a Background - Because of its antiarrhythmic potency and due to the lack of alternatives, amiodarone is often used for antiarrhythmic therapy in patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator systems. To date, robust data on the safety and clinical benefit of amiodarone therapy in these patients are missing. - Objective - The purpose of this study was to assess the periprocedural and postprocedural outcomes of combined therapy with beta-blockers plus amiodarone compared to treatment with single beta-blockers in the “real-life” cohort of ICD recipients of the German DEVICE registry. - Methods - A total of 4499 patients who underwent ICD implantation, revision, or upgrade in 49 centers participating in the German DEVICE registry were enrolled from March 2007 to February 2014. - Results - Amiodarone had no significant effect on the success of defibrillation testing. Early implantation-associated complications were similar between the groups. However, 1-year overall mortality was significantly higher in the beta-blocker plus amiodarone cohort (adjusted hazard ratio 2.09; P <.001). Interestingly, among the surviving patients, amiodarone was not associated with a significantly reduced risk of ICD discharges or syncopal events. Furthermore, the occurrence of ventricular tachycardia (VT) storm or incessant VTs and the number of patients scheduled for intracardiac ablation did not differ among both groups, whereas the rate of rehospitalization was lower in the cohort with only beta-blockers. - Conclusions - Although amiodarone has no adverse effect on the success of defibrillation testing, our data suggest an increased all-cause mortality under amiodarone therapy, especially in the subgroups of patients with sinus rhythm or severely reduced left ventricular function. In surviving patients, rates of arrhythmic events were comparable. 
650 4 |a Amiodarone 
650 4 |a Antiarrhythmic drugs 
650 4 |a Beta-blocker 
650 4 |a Cardiac resynchronization therapy-defibrillator 
650 4 |a Implantable cardioverter-defibrillator 
700 1 |a Ince, Hüseyin  |e VerfasserIn  |4 aut 
700 1 |a Stellbrink, Christoph  |e VerfasserIn  |4 aut 
700 1 |a Kleemann, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Eckardt, Lars  |e VerfasserIn  |4 aut 
700 1 |a Brachmann, Johannes  |e VerfasserIn  |4 aut 
700 1 |a Gonska, Bernd-Dieter  |e VerfasserIn  |4 aut 
700 1 |a Kääb, Stefan  |e VerfasserIn  |4 aut 
700 1 |a Perings, Christian A.  |e VerfasserIn  |4 aut 
700 1 |a Jung, Werner  |e VerfasserIn  |4 aut 
700 1 |a Lugenbiel, Patrick  |d 1982-  |e VerfasserIn  |0 (DE-588)137855710  |0 (DE-627)696120062  |0 (DE-576)305349414  |4 aut 
700 1 |a Hochadel, Matthias  |e VerfasserIn  |0 (DE-588)1128413051  |0 (DE-627)88289871X  |0 (DE-576)485901811  |4 aut 
700 1 |a Senges, Jochen  |d 1942-  |e VerfasserIn  |0 (DE-588)1027133479  |0 (DE-627)728326620  |0 (DE-576)372508685  |4 aut 
700 1 |a Frey, Norbert  |e VerfasserIn  |0 (DE-588)141244976  |0 (DE-627)625824075  |0 (DE-576)322969514  |4 aut 
700 1 |a Schmidt, Constanze  |e VerfasserIn  |0 (DE-588)1055852174  |0 (DE-627)792733142  |0 (DE-576)411903721  |4 aut 
773 0 8 |i Enthalten in  |t Heart rhythm  |d New York, NY [u.a.] : Elsevier, 2004  |g 20(2023), 4 vom: März, Seite 501-509  |h Online-Ressource  |w (DE-627)391333739  |w (DE-600)2152161-X  |w (DE-576)309205557  |x 1556-3871  |7 nnas  |a Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients insights from the German DEVICE registry 
773 1 8 |g volume:20  |g year:2023  |g number:4  |g month:03  |g pages:501-509  |g extent:9  |a Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients insights from the German DEVICE registry 
856 4 0 |u https://doi.org/10.1016/j.hrthm.2022.12.009  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1547527122026972  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230615 
993 |a Article 
994 |a 2023 
998 |g 1055852174  |a Schmidt, Constanze  |m 1055852174:Schmidt, Constanze  |d 910000  |d 910100  |d 50000  |e 910000PS1055852174  |e 910100PS1055852174  |e 50000PS1055852174  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 15  |y j 
998 |g 141244976  |a Frey, Norbert  |m 141244976:Frey, Norbert  |d 910000  |d 910100  |e 910000PF141244976  |e 910100PF141244976  |k 0/910000/  |k 1/910000/910100/  |p 14 
998 |g 1027133479  |a Senges, Jochen  |m 1027133479:Senges, Jochen  |d 50000  |e 50000PS1027133479  |k 0/50000/  |p 13 
998 |g 137855710  |a Lugenbiel, Patrick  |m 137855710:Lugenbiel, Patrick  |d 910000  |d 910100  |d 50000  |e 910000PL137855710  |e 910100PL137855710  |e 50000PL137855710  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 11 
998 |g 1055852441  |a Wiedmann, Felix Tobias  |m 1055852441:Wiedmann, Felix Tobias  |d 910000  |d 910100  |e 910000PW1055852441  |e 910100PW1055852441  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1849775273  |e 4338678704 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients insights from the German DEVICE registryHeart rhythm","type":{"media":"Online-Ressource","bibl":"periodical"},"part":{"text":"20(2023), 4 vom: März, Seite 501-509","pages":"501-509","extent":"9","issue":"4","volume":"20","year":"2023"},"language":["eng"],"pubHistory":["1.2004 -"],"note":["Gesehen am 01.11.11"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1556-3871"],"eki":["391333739"],"zdb":["2152161-X"]},"title":[{"title":"Heart rhythm","title_sort":"Heart rhythm"}],"origin":[{"dateIssuedKey":"2004","publisherPlace":"New York, NY [u.a.]","publisher":"Elsevier","dateIssuedDisp":"2004-"}],"recId":"391333739"}],"origin":[{"dateIssuedDisp":"28 March 2023","dateIssuedKey":"2023"}],"title":[{"subtitle":"insights from the German DEVICE registry","title":"Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients","title_sort":"Single beta-blocker or combined amiodarone therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator patients"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1849775273"],"doi":["10.1016/j.hrthm.2022.12.009"]},"physDesc":[{"extent":"9 S."}],"person":[{"display":"Wiedmann, Felix Tobias","given":"Felix Tobias","role":"aut","family":"Wiedmann"},{"display":"Ince, Hüseyin","given":"Hüseyin","role":"aut","family":"Ince"},{"display":"Stellbrink, Christoph","given":"Christoph","role":"aut","family":"Stellbrink"},{"given":"Thomas","display":"Kleemann, Thomas","family":"Kleemann","role":"aut"},{"given":"Lars","display":"Eckardt, Lars","role":"aut","family":"Eckardt"},{"family":"Brachmann","role":"aut","display":"Brachmann, Johannes","given":"Johannes"},{"given":"Bernd-Dieter","display":"Gonska, Bernd-Dieter","family":"Gonska","role":"aut"},{"display":"Kääb, Stefan","given":"Stefan","family":"Kääb","role":"aut"},{"given":"Christian A.","display":"Perings, Christian A.","role":"aut","family":"Perings"},{"role":"aut","family":"Jung","given":"Werner","display":"Jung, Werner"},{"given":"Patrick","display":"Lugenbiel, Patrick","family":"Lugenbiel","role":"aut"},{"family":"Hochadel","role":"aut","given":"Matthias","display":"Hochadel, Matthias"},{"family":"Senges","role":"aut","display":"Senges, Jochen","given":"Jochen"},{"family":"Frey","role":"aut","given":"Norbert","display":"Frey, Norbert"},{"role":"aut","family":"Schmidt","display":"Schmidt, Constanze","given":"Constanze"}],"recId":"1849775273","note":["Online verfügbar 10. Dezember 2022, Artikelversion 28. März 2023","Gesehen am 15.06.2023"],"language":["eng"],"name":{"displayForm":["Felix Wiedmann, Hüseyin Ince, Christoph Stellbrink, Thomas Kleemann, Lars Eckardt, Johannes Brachmann, Bernd-Dieter Gonska, Stefan Kääb, Christian A. Perings, Werner Jung, Patrick Lugenbiel, Matthias Hochadel, Jochen Senges, Norbert Frey, Constanze Schmidt"]}} 
SRT |a WIEDMANNFESINGLEBETA2820