Patient-specific electronic decision support reduces prescription of excessive doses

Objectives Prescription of excessive doses is the most common prescription error, provoking dose-dependent adverse drug reactions. Clinical decision support systems (CDSS) can prevent prescription errors especially when mainly clinically relevant warnings are issued. We have built and evaluated a CD...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Seidling, Hanna (VerfasserIn) , Schmitt, Simon Petrik Walter (VerfasserIn) , Bruckner, Thomas (VerfasserIn) , Kaltschmidt, Jens (VerfasserIn) , Pruszydlo, Markus Gerhard (VerfasserIn) , Senger, Christian (VerfasserIn) , Bertsche, Thilo (VerfasserIn) , Walter-Sack, Ingeborg (VerfasserIn) , Haefeli, Walter E. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 27 April 2010
In: Quality and safety in health care
Year: 2010, Jahrgang: 19, Heft: 5, Pages: 1-7
ISSN:1475-3901
DOI:10.1136/qshc.2009.033175
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1136/qshc.2009.033175
Verlag, lizenzpflichtig, Volltext: https://qualitysafety.bmj.com/content/19/5/e15
Volltext
Verfasserangaben:H.M. Seidling, S.P.W. Schmitt, T. Bruckner, J. Kaltschmidt, M.G. Pruszydlo, C. Senger, T. Bertsche, I. Walter-Sack, W.E. Haefeli

MARC

LEADER 00000caa a2200000 c 4500
001 1850659796
003 DE-627
005 20230710130047.0
007 cr uuu---uuuuu
008 230620s2010 xx |||||o 00| ||eng c
024 7 |a 10.1136/qshc.2009.033175  |2 doi 
035 |a (DE-627)1850659796 
035 |a (DE-599)KXP1850659796 
035 |a (OCoLC)1389793798 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Seidling, Hanna  |d 1982-  |e VerfasserIn  |0 (DE-588)140696512  |0 (DE-627)703758861  |0 (DE-576)319591433  |4 aut 
245 1 0 |a Patient-specific electronic decision support reduces prescription of excessive doses  |c H.M. Seidling, S.P.W. Schmitt, T. Bruckner, J. Kaltschmidt, M.G. Pruszydlo, C. Senger, T. Bertsche, I. Walter-Sack, W.E. Haefeli 
264 1 |c 27 April 2010 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.06.2023 
520 |a Objectives Prescription of excessive doses is the most common prescription error, provoking dose-dependent adverse drug reactions. Clinical decision support systems (CDSS) can prevent prescription errors especially when mainly clinically relevant warnings are issued. We have built and evaluated a CDSS providing upper dose limits personalised to individual patient characteristics thus guaranteeing for specific warnings. - Methods For 170 compounds, detailed information on upper dose limits (according to the drug label) was compiled. A comprehensive software-algorithm extracted relevant patient information from the electronic chart (eg, age, renal function, comedication). The CDSS was integrated into the local prescribing platform for outpatients and patients at discharge, providing immediate dosage feedback. Its impact was evaluated in a 90-day intervention study (phase 1: baseline; phase 2: intervention). Outcome measures were frequency of excessive doses before and after intervention considering potential induction of new medication errors. Moreover, predictors for alert adherence were analysed. - Results In phase 1, 552 of 12 197 (4.5%) prescriptions exceeded upper dose limits. In phase 2, initially 559 warnings were triggered (4.8%, p=0.37). Physicians were responsive to one in four warnings mostly adjusting dosages. Thus, the final prescription rate of excessive doses was reduced to 3.6%, with 20% less excessive doses compared with baseline (p<0.001). No new manifest prescription errors were induced. Physicians' alert adherence correlated with patients' age, prescribed drug class, and reason for the alert. - Conclusion During the 90-day study, implementation of a highly specific algorithm-based CDSS substantially improved prescribing quality with a high acceptance rate compared with previous studies. 
650 4 |a Clinical decision support system 
650 4 |a continuous quality 
650 4 |a decision analysis 
650 4 |a information technology 
650 4 |a medication error 
650 4 |a overdosage 
700 1 |a Schmitt, Simon Petrik Walter  |d 1975-  |e VerfasserIn  |0 (DE-588)143825712  |0 (DE-627)655101691  |0 (DE-576)339101814  |4 aut 
700 1 |a Bruckner, Thomas  |d 1956-  |e VerfasserIn  |0 (DE-588)136046215  |0 (DE-627)574429298  |0 (DE-576)300798768  |4 aut 
700 1 |a Kaltschmidt, Jens  |e VerfasserIn  |0 (DE-588)1055078568  |0 (DE-627)792645707  |0 (DE-576)411150863  |4 aut 
700 1 |a Pruszydlo, Markus Gerhard  |d 1979-  |e VerfasserIn  |0 (DE-588)142996157  |0 (DE-627)641424744  |0 (DE-576)334534666  |4 aut 
700 1 |a Senger, Christian  |d 1978-  |e VerfasserIn  |0 (DE-588)143545019  |0 (DE-627)647321904  |0 (DE-576)337617597  |4 aut 
700 1 |a Bertsche, Thilo  |e VerfasserIn  |0 (DE-588)1075392403  |0 (DE-627)833264176  |0 (DE-576)184800757  |4 aut 
700 1 |a Walter-Sack, Ingeborg  |e VerfasserIn  |0 (DE-588)1065347987  |0 (DE-627)815887957  |0 (DE-576)425021408  |4 aut 
700 1 |a Haefeli, Walter E.  |d 1958-  |e VerfasserIn  |0 (DE-588)124572359  |0 (DE-627)656806141  |0 (DE-576)340514221  |4 aut 
773 0 8 |i Enthalten in  |t Quality and safety in health care  |d London : BMJ Publishing Group, 2002  |g 19(2010), 5, Artikel-ID e15, Seite 1-7  |h Online-Ressource  |w (DE-627)324485697  |w (DE-600)2027244-3  |w (DE-576)276271475  |x 1475-3901  |7 nnas  |a Patient-specific electronic decision support reduces prescription of excessive doses 
773 1 8 |g volume:19  |g year:2010  |g number:5  |g elocationid:e15  |g pages:1-7  |g extent:7  |a Patient-specific electronic decision support reduces prescription of excessive doses 
856 4 0 |u https://doi.org/10.1136/qshc.2009.033175  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://qualitysafety.bmj.com/content/19/5/e15  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230620 
993 |a Article 
994 |a 2010 
998 |g 124572359  |a Haefeli, Walter E.  |m 124572359:Haefeli, Walter E.  |d 910000  |d 910100  |e 910000PH124572359  |e 910100PH124572359  |k 0/910000/  |k 1/910000/910100/  |p 9  |y j 
998 |g 1065347987  |a Walter-Sack, Ingeborg  |m 1065347987:Walter-Sack, Ingeborg  |d 50000  |e 50000PW1065347987  |k 0/50000/  |p 8 
998 |g 1075392403  |a Bertsche, Thilo  |m 1075392403:Bertsche, Thilo  |d 50000  |e 50000PB1075392403  |k 0/50000/  |p 7 
998 |g 143545019  |a Senger, Christian  |m 143545019:Senger, Christian  |d 50000  |e 50000PS143545019  |k 0/50000/  |p 6 
998 |g 142996157  |a Pruszydlo, Markus Gerhard  |m 142996157:Pruszydlo, Markus Gerhard  |d 910000  |e 910000PP142996157  |k 0/910000/  |p 5 
998 |g 1055078568  |a Kaltschmidt, Jens  |m 1055078568:Kaltschmidt, Jens  |d 910000  |d 910100  |e 910000PK1055078568  |e 910100PK1055078568  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 136046215  |a Bruckner, Thomas  |m 136046215:Bruckner, Thomas  |d 910000  |d 999701  |e 910000PB136046215  |e 999701PB136046215  |k 0/910000/  |k 1/910000/999701/  |p 3 
998 |g 143825712  |a Schmitt, Simon Petrik Walter  |m 143825712:Schmitt, Simon Petrik Walter  |d 910000  |d 910100  |e 910000PS143825712  |e 910100PS143825712  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 140696512  |a Seidling, Hanna  |m 140696512:Seidling, Hanna  |d 910000  |d 910100  |e 910000PS140696512  |e 910100PS140696512  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1850659796  |e 4340886815 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Patient-specific electronic decision support reduces prescription of excessive doses","title":"Patient-specific electronic decision support reduces prescription of excessive doses"}],"person":[{"display":"Seidling, Hanna","family":"Seidling","given":"Hanna","role":"aut"},{"given":"Simon Petrik Walter","display":"Schmitt, Simon Petrik Walter","family":"Schmitt","role":"aut"},{"role":"aut","display":"Bruckner, Thomas","family":"Bruckner","given":"Thomas"},{"role":"aut","family":"Kaltschmidt","display":"Kaltschmidt, Jens","given":"Jens"},{"given":"Markus Gerhard","family":"Pruszydlo","display":"Pruszydlo, Markus Gerhard","role":"aut"},{"family":"Senger","display":"Senger, Christian","given":"Christian","role":"aut"},{"family":"Bertsche","display":"Bertsche, Thilo","given":"Thilo","role":"aut"},{"role":"aut","display":"Walter-Sack, Ingeborg","family":"Walter-Sack","given":"Ingeborg"},{"role":"aut","given":"Walter E.","display":"Haefeli, Walter E.","family":"Haefeli"}],"physDesc":[{"extent":"7 S."}],"relHost":[{"part":{"issue":"5","year":"2010","extent":"7","pages":"1-7","text":"19(2010), 5, Artikel-ID e15, Seite 1-7","volume":"19"},"title":[{"title":"Quality and safety in health care","title_sort":"Quality and safety in health care"}],"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"QSCH"}],"id":{"issn":["1475-3901"],"zdb":["2027244-3"],"eki":["324485697"]},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2002","publisher":"BMJ Publishing Group","publisherPlace":"London","dateIssuedDisp":"2002-2010"}],"note":["Gesehen am 14.03.11"],"pubHistory":["11.2002 - 19.2010"],"recId":"324485697","disp":"Patient-specific electronic decision support reduces prescription of excessive dosesQuality and safety in health care"}],"id":{"eki":["1850659796"],"doi":["10.1136/qshc.2009.033175"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"27 April 2010","dateIssuedKey":"2010"}],"name":{"displayForm":["H.M. Seidling, S.P.W. Schmitt, T. Bruckner, J. Kaltschmidt, M.G. Pruszydlo, C. Senger, T. Bertsche, I. Walter-Sack, W.E. Haefeli"]},"recId":"1850659796","note":["Gesehen am 20.06.2023"]} 
SRT |a SEIDLINGHAPATIENTSPE2720