Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses

We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused sa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Naujokaitis, Tadas (VerfasserIn) , Khoramnia, Ramin (VerfasserIn) , Łabuz, Grzegorz (VerfasserIn) , Choi, Chul Young (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn) , Tandogan, Tamer (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 19 May 2023
In: Diagnostics
Year: 2023, Jahrgang: 13, Heft: 10, Pages: 1-12
ISSN:2075-4418
DOI:10.3390/diagnostics13101804
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3390/diagnostics13101804
Verlag, kostenfrei, Volltext: https://www.mdpi.com/2075-4418/13/10/1804
Volltext
Verfasserangaben:Tadas Naujokaitis, Ramin Khoramnia, Grzegorz Łabuz, Chul Young Choi, Gerd U. Auffarth and Tamer Tandogan

MARC

LEADER 00000caa a2200000 c 4500
001 1851192255
003 DE-627
005 20230706201750.0
007 cr uuu---uuuuu
008 230628s2023 xx |||||o 00| ||eng c
024 7 |a 10.3390/diagnostics13101804  |2 doi 
035 |a (DE-627)1851192255 
035 |a (DE-599)KXP1851192255 
035 |a (OCoLC)1389527960 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Naujokaitis, Tadas  |e VerfasserIn  |0 (DE-588)1240859635  |0 (DE-627)1769941541  |4 aut 
245 1 0 |a Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses  |c Tadas Naujokaitis, Ramin Khoramnia, Grzegorz Łabuz, Chul Young Choi, Gerd U. Auffarth and Tamer Tandogan 
264 1 |c 19 May 2023 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.06.2023 
520 |a We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images. In addition, we assessed light transmission through the IOLs. The MTF values of opacified IOLs at 3-mm aperture were similar to those of clear lenses, with the median (interquartile range) values of 0.74 (0.01) vs. 0.76 (0.03) at the spatial frequency of 50 line pairs per millimeter in clear and opacified IOLs, respectively. The Strehl ratio of opacified lenses was not lower than that of clear lenses. The USAF-chart analysis showed a considerable reduction in brightness in opacified IOLs. The median (interquartile range) relative light transmission of opacified IOLs in comparison to clear lenses was 55.6% (20.8%) at the aperture size of 3 mm. In conclusion, the explanted opacified IOLs had comparable MTF values to those of clear lenses but significantly reduced light transmission. 
650 4 |a calcification 
650 4 |a hydrophilic 
650 4 |a intraocular lens 
650 4 |a light transmission 
650 4 |a modulation transfer function 
650 4 |a opacification 
650 4 |a optical quality 
700 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
700 1 |a Łabuz, Grzegorz  |e VerfasserIn  |0 (DE-588)1185406743  |0 (DE-627)1664595244  |4 aut 
700 1 |a Choi, Chul Young  |e VerfasserIn  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
700 1 |a Tandogan, Tamer  |d 1965-  |e VerfasserIn  |0 (DE-588)129861812  |0 (DE-627)48236419X  |0 (DE-576)297874578  |4 aut 
773 0 8 |i Enthalten in  |t Diagnostics  |d Basel : MDPI, 2011  |g 13(2023), 10 vom: Mai, Artikel-ID 1804, Seite 1-12  |h Online-Ressource  |w (DE-627)718627814  |w (DE-600)2662336-5  |w (DE-576)365413917  |x 2075-4418  |7 nnas  |a Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses 
773 1 8 |g volume:13  |g year:2023  |g number:10  |g month:05  |g elocationid:1804  |g pages:1-12  |g extent:12  |a Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses 
856 4 0 |u https://doi.org/10.3390/diagnostics13101804  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2075-4418/13/10/1804  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230628 
993 |a Article 
994 |a 2023 
998 |g 129861812  |a Tandogan, Tamer  |m 129861812:Tandogan, Tamer  |d 910000  |d 910900  |d 50000  |e 910000PT129861812  |e 910900PT129861812  |e 50000PT129861812  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 6  |y j 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 5 
998 |g 1185406743  |a Łabuz, Grzegorz  |m 1185406743:Łabuz, Grzegorz  |d 910000  |d 910900  |e 910000PŁ1185406743  |e 910900PŁ1185406743  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |d 50000  |e 910000PK132573954  |e 910900PK132573954  |e 50000PK132573954  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 2 
998 |g 1240859635  |a Naujokaitis, Tadas  |m 1240859635:Naujokaitis, Tadas  |d 910000  |d 910900  |e 910000PN1240859635  |e 910900PN1240859635  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1851192255  |e 4344333284 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1851192255"],"doi":["10.3390/diagnostics13101804"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"19 May 2023"}],"name":{"displayForm":["Tadas Naujokaitis, Ramin Khoramnia, Grzegorz Łabuz, Chul Young Choi, Gerd U. Auffarth and Tamer Tandogan"]},"relHost":[{"title":[{"subtitle":"open access journal","title":"Diagnostics","title_sort":"Diagnostics"}],"part":{"extent":"12","volume":"13","text":"13(2023), 10 vom: Mai, Artikel-ID 1804, Seite 1-12","pages":"1-12","issue":"10","year":"2023"},"pubHistory":["1.2011 -"],"language":["eng"],"recId":"718627814","disp":"Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lensesDiagnostics","note":["Gesehen am 28.05.2020"],"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"issn":["2075-4418"],"eki":["718627814"],"zdb":["2662336-5"]},"origin":[{"dateIssuedDisp":"2011-","dateIssuedKey":"2011","publisher":"MDPI","publisherPlace":"Basel"}],"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"12 S."}],"title":[{"title":"Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses","title_sort":"Imaging function and relative light transmission of explanted opacified hydrophilic acrylic intraocular lenses"}],"person":[{"family":"Naujokaitis","given":"Tadas","display":"Naujokaitis, Tadas","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Khoramnia, Ramin","roleDisplay":"VerfasserIn","role":"aut","family":"Khoramnia","given":"Ramin"},{"given":"Grzegorz","family":"Łabuz","role":"aut","display":"Łabuz, Grzegorz","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Choi, Chul Young","given":"Chul Young","family":"Choi"},{"roleDisplay":"VerfasserIn","display":"Auffarth, Gerd U.","role":"aut","family":"Auffarth","given":"Gerd U."},{"display":"Tandogan, Tamer","roleDisplay":"VerfasserIn","role":"aut","family":"Tandogan","given":"Tamer"}],"language":["eng"],"recId":"1851192255","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 28.06.2023"]} 
SRT |a NAUJOKAITIIMAGINGFUN1920