Quantitative Pulmonary Perfusion Magnetic Resonance Imaging: Influence of Temporal Resolution and Signal-to-Noise Ratio

Purpose: - To investigate the influence of the contrast-to-noise ratio (CNR) and temporal resolution of 3D dynamic contrast-enhanced magnetic resonance imaging on the quantification of pulmonary perfusion parameters by means of Monte-Carlo simulations and a volunteer study. - Methods: - Quantifica...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ingrisch, Michael Stefan (VerfasserIn) , Dietrich, Olaf (VerfasserIn) , Attenberger, Ulrike (VerfasserIn) , Nikolaou, Konstantin (VerfasserIn) , Sourbron, Steven (VerfasserIn) , Reiser, Maximilian (VerfasserIn) , Fink, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [January 2010]
In: Investigative radiology
Year: 2010, Jahrgang: 45, Heft: 1, Pages: 7-14
ISSN:1536-0210
DOI:10.1097/RLI.0b013e3181bc2d0c
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/RLI.0b013e3181bc2d0c
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/investigativeradiology/Fulltext/2010/01000/Quantitative_Pulmonary_Perfusion_Magnetic.2.aspx
Volltext
Verfasserangaben:Michael Ingrisch, Olaf Dietrich, Ulrike I. Attenberger, Konstantin Nikolaou, Steven Sourbron, Maximilian F. Reiser, and Christian Fink

MARC

LEADER 00000caa a2200000 c 4500
001 1851200193
003 DE-627
005 20240328080732.0
007 cr uuu---uuuuu
008 230628s2010 xx |||||o 00| ||eng c
024 7 |a 10.1097/RLI.0b013e3181bc2d0c  |2 doi 
035 |a (DE-627)1851200193 
035 |a (DE-599)KXP1851200193 
035 |a (OCoLC)1389793827 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ingrisch, Michael Stefan  |d 1979-  |e VerfasserIn  |0 (DE-588)1028899467  |0 (DE-627)731802284  |0 (DE-576)376329750  |4 aut 
245 1 0 |a Quantitative Pulmonary Perfusion Magnetic Resonance Imaging  |b Influence of Temporal Resolution and Signal-to-Noise Ratio  |c Michael Ingrisch, Olaf Dietrich, Ulrike I. Attenberger, Konstantin Nikolaou, Steven Sourbron, Maximilian F. Reiser, and Christian Fink 
264 1 |c [January 2010] 
300 |b Illustrationen 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.06.2023 
520 |a Purpose: - To investigate the influence of the contrast-to-noise ratio (CNR) and temporal resolution of 3D dynamic contrast-enhanced magnetic resonance imaging on the quantification of pulmonary perfusion parameters by means of Monte-Carlo simulations and a volunteer study. - Methods: - Quantification of perfusion parameters such as pulmonary blood flow (PBF) and pulmonary blood volume (PBV) was simulated using synthetic data with varying CNR (noise standard deviations ranging from 0% to 25% of the parenchymal signal maximum) and different temporal resolutions from 1 to 5 seconds. Simulation results were compared with perfusion measurements in 9 healthy volunteers (age: 18-31) using dynamic 3D gradient-echo sequences with different k-space acquisition schemes, resulting in different temporal resolutions of 1.1, 1.3, and 2.0 seconds per volume and varying CNR. Lung parenchyma was segmented using a semiautomatic technique, and PBF, PBV, as well as MTT were determined pixelwise using Tikhonov-regularized deconvolution with an optimized L-curve criterion. - Results: - The simulations showed a breakdown of the deconvolution algorithm for temporal resolutions lower than 3 s. PBF was increasingly underestimated with decreasing CNR; the temporal resolution had little influence on PBF estimates in the investigated range. PBV, on the other hand, was more dependent on the temporal resolution and showed less, but noticeable influence of the CNR. For low temporal resolutions, PBV was overestimated. - In the volunteer study, no significant differences of PBF between the different sequences were found; however, PBV was underestimated by the slowest sequence, in contrast to the simulation results. - Conclusion: - Both the mathematical simulations and volunteer measurements showed that the temporal resolution has less influence than the CNR on the quantification of PBF. On the other hand, PBV is more influenced by temporal resolution than by CNR. This indicates that the gain in measurement speed that can be obtained by modern acceleration schemes need not be invested in ultra-high temporal resolution. Instead, sequence optimization should aim for a suitable balance of sufficient CNR on the one hand, and sufficient temporal resolution on the other hand, whereas maintaining a high spatial resolution. 
700 1 |a Dietrich, Olaf  |e VerfasserIn  |4 aut 
700 1 |a Attenberger, Ulrike  |d 1980-  |e VerfasserIn  |0 (DE-588)131554859  |0 (DE-627)510698557  |0 (DE-576)298582775  |4 aut 
700 1 |a Nikolaou, Konstantin  |d 1973-  |e VerfasserIn  |0 (DE-588)12262436X  |0 (DE-627)705975630  |0 (DE-576)293353131  |4 aut 
700 1 |a Sourbron, Steven  |e VerfasserIn  |4 aut 
700 1 |a Reiser, Maximilian  |d 1948-  |e VerfasserIn  |0 (DE-588)108567478  |0 (DE-627)509047114  |0 (DE-576)289616379  |4 aut 
700 1 |a Fink, Christian  |d 1971-  |e VerfasserIn  |0 (DE-588)121198014  |0 (DE-627)705299767  |0 (DE-576)292581882  |4 aut 
773 0 8 |i Enthalten in  |t Investigative radiology  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1966  |g 45(2010), 1 vom: Jan., Seite 7-14  |h Online-Ressource  |w (DE-627)326645322  |w (DE-600)2041543-6  |w (DE-576)09442568X  |x 1536-0210  |7 nnas  |a Quantitative Pulmonary Perfusion Magnetic Resonance Imaging Influence of Temporal Resolution and Signal-to-Noise Ratio 
773 1 8 |g volume:45  |g year:2010  |g number:1  |g month:01  |g pages:7-14  |g extent:8  |a Quantitative Pulmonary Perfusion Magnetic Resonance Imaging Influence of Temporal Resolution and Signal-to-Noise Ratio 
856 4 0 |u https://doi.org/10.1097/RLI.0b013e3181bc2d0c  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/investigativeradiology/Fulltext/2010/01000/Quantitative_Pulmonary_Perfusion_Magnetic.2.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230628 
993 |a Article 
994 |a 2010 
998 |g 121198014  |a Fink, Christian  |m 121198014:Fink, Christian  |d 60000  |d 62900  |e 60000PF121198014  |e 62900PF121198014  |k 0/60000/  |k 1/60000/62900/  |p 7  |y j 
998 |g 131554859  |a Attenberger, Ulrike  |m 131554859:Attenberger, Ulrike  |d 60000  |e 60000PA131554859  |k 0/60000/  |p 3 
999 |a KXP-PPN1851200193  |e 4344350782 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Quantitative Pulmonary Perfusion Magnetic Resonance Imaging","title_sort":"Quantitative Pulmonary Perfusion Magnetic Resonance Imaging","subtitle":"Influence of Temporal Resolution and Signal-to-Noise Ratio"}],"id":{"eki":["1851200193"],"doi":["10.1097/RLI.0b013e3181bc2d0c"]},"name":{"displayForm":["Michael Ingrisch, Olaf Dietrich, Ulrike I. Attenberger, Konstantin Nikolaou, Steven Sourbron, Maximilian F. Reiser, and Christian Fink"]},"physDesc":[{"noteIll":"Illustrationen","extent":"8 S."}],"origin":[{"dateIssuedDisp":"[January 2010]","dateIssuedKey":"2010"}],"relHost":[{"id":{"issn":["1536-0210"],"eki":["326645322"],"zdb":["2041543-6"]},"recId":"326645322","part":{"issue":"1","volume":"45","pages":"7-14","extent":"8","year":"2010","text":"45(2010), 1 vom: Jan., Seite 7-14"},"note":["Gesehen am 01.03.11"],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1966 -"],"title":[{"subtitle":"a journal of clinical and laboratory research","title_sort":"Investigative radiology","title":"Investigative radiology"}],"language":["eng"],"disp":"Quantitative Pulmonary Perfusion Magnetic Resonance Imaging Influence of Temporal Resolution and Signal-to-Noise RatioInvestigative radiology","origin":[{"dateIssuedDisp":"1966-","publisher":"Lippincott Williams & Wilkins ; Ovid","publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]","dateIssuedKey":"1966"}],"physDesc":[{"extent":"Online-Ressource"}]}],"person":[{"given":"Michael Stefan","roleDisplay":"VerfasserIn","role":"aut","display":"Ingrisch, Michael Stefan","family":"Ingrisch"},{"family":"Dietrich","display":"Dietrich, Olaf","given":"Olaf","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Attenberger, Ulrike","given":"Ulrike","roleDisplay":"VerfasserIn","role":"aut","family":"Attenberger"},{"family":"Nikolaou","display":"Nikolaou, Konstantin","given":"Konstantin","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Sourbron, Steven","roleDisplay":"VerfasserIn","role":"aut","given":"Steven","family":"Sourbron"},{"family":"Reiser","given":"Maximilian","role":"aut","roleDisplay":"VerfasserIn","display":"Reiser, Maximilian"},{"given":"Christian","role":"aut","roleDisplay":"VerfasserIn","display":"Fink, Christian","family":"Fink"}],"language":["eng"],"note":["Gesehen am 28.06.2023"],"recId":"1851200193","type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a INGRISCHMIQUANTITATI2010