Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process: the MIRA appliance

Objective: Intermaxillary elastics, anchored skeletally, represent a promising concept for treatment in adolescent patients with skeletal Class III anomalies. A challenge in existing concepts is the survival rate of the miniscrews in the mandible or the invasiveness of the bone anchors. A novel conc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hodecker, Lutz (VerfasserIn) , Kühle, Reinald (VerfasserIn) , Bouffleur, Frederic (VerfasserIn) , Roser, Christoph (VerfasserIn) , Lux, Christopher J. (VerfasserIn) , Scheurer, Carolien A. J. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 19 May 2023
In: Bioengineering
Year: 2023, Jahrgang: 10, Heft: 5, Pages: 1-12
ISSN:2306-5354
DOI:10.3390/bioengineering10050616
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/bioengineering10050616
Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2306-5354/10/5/616
Volltext
Verfasserangaben:Lutz D. Hodecker, Reinald Kuehle, Frederic Weichel, Christoph J. Roser, Christopher J. Lux and Carolien A.J. Bauer

MARC

LEADER 00000caa a2200000 c 4500
001 1851794557
003 DE-627
005 20230706201108.0
007 cr uuu---uuuuu
008 230705s2023 xx |||||o 00| ||eng c
024 7 |a 10.3390/bioengineering10050616  |2 doi 
035 |a (DE-627)1851794557 
035 |a (DE-599)KXP1851794557 
035 |a (OCoLC)1389527445 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hodecker, Lutz  |e VerfasserIn  |0 (DE-588)1241845387  |0 (DE-627)1771774967  |4 aut 
245 1 0 |a Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process  |b the MIRA appliance  |c Lutz D. Hodecker, Reinald Kuehle, Frederic Weichel, Christoph J. Roser, Christopher J. Lux and Carolien A.J. Bauer 
264 1 |c 19 May 2023 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.07.2023 
520 |a Objective: Intermaxillary elastics, anchored skeletally, represent a promising concept for treatment in adolescent patients with skeletal Class III anomalies. A challenge in existing concepts is the survival rate of the miniscrews in the mandible or the invasiveness of the bone anchors. A novel concept, the mandibular interradicular anchor (MIRA) appliance, for improving skeletal anchorage in the mandible, will be presented and discussed. Clinical case: In a ten-year-old female patient with a moderate skeletal Class III, the novel MIRA concept, combined with maxillary protraction, was applied. This involved the use of a CAD/CAM-fabricated indirect skeletal anchorage appliance in the mandible, with interradicularly placed miniscrews distal to each canine (MIRA appliance), and a hybrid hyrax in the maxilla with paramedian placed miniscrews. The modified alt-RAMEC protocol involved an intermittent weekly activation for five weeks. Class III elastics were worn for a period of seven months. This was followed by alignment with a multi-bracket appliance. Discussion: The cephalometric analysis before and after therapy shows an improvement of the Wits value (+3.8 mm), SNA (+5 degrees), and ANB (+3 degrees). Dentally, a transversal postdevelopment in the maxilla (+4 mm) and a labial tip of the maxillary (+3.4 degrees) and mandibular anterior teeth (+4.7 degrees) with gap formation is observed. Conclusion: The MIRA appliance represents a less invasive and esthetic alternative to the existing concepts, especially with two miniscrews in the mandible per side. In addition, MIRA can be selected for complex orthodontic tasks, such as molar uprighting and mesialization. 
650 4 |a angle Class III 
650 4 |a case report 
650 4 |a computer aided design 
650 4 |a growth and development 
650 4 |a orthodontic appliances 
650 4 |a orthodontic anchorage procedure 
650 4 |a retrognathia 
700 1 |a Kühle, Reinald  |d 1984-  |e VerfasserIn  |0 (DE-588)1106415639  |0 (DE-627)863142214  |0 (DE-576)474109267  |4 aut 
700 1 |a Bouffleur, Frederic  |d 1993-  |e VerfasserIn  |0 (DE-588)1214267211  |0 (DE-627)172523324X  |4 aut 
700 1 |a Roser, Christoph  |e VerfasserIn  |0 (DE-588)1214267378  |0 (DE-627)1725233789  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Scheurer, Carolien A. J.  |d 1995-  |e VerfasserIn  |0 (DE-588)1261503082  |0 (DE-627)180872528X  |4 aut 
773 0 8 |i Enthalten in  |t Bioengineering  |d Basel : MDPI, 2014  |g 10(2023), 5, Artikel-ID 616, Seite 1-12  |h Online-Ressource  |w (DE-627)774814020  |w (DE-600)2746191-9  |w (DE-576)399193375  |x 2306-5354  |7 nnas  |a Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process the MIRA appliance 
773 1 8 |g volume:10  |g year:2023  |g number:5  |g elocationid:616  |g pages:1-12  |g extent:12  |a Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process the MIRA appliance 
856 4 0 |u https://doi.org/10.3390/bioengineering10050616  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2306-5354/10/5/616  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230705 
993 |a Article 
994 |a 2023 
998 |g 1261503082  |a Scheurer, Carlien A. J.  |m 1261503082:Scheurer, Carlien A. J.  |d 910000  |d 910800  |e 910000PS1261503082  |e 910800PS1261503082  |k 0/910000/  |k 1/910000/910800/  |p 6  |y j 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1214267378  |a Roser, Christoph  |m 1214267378:Roser, Christoph  |d 910000  |d 910800  |e 910000PR1214267378  |e 910800PR1214267378  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1214267211  |a Bouffleur, Frederic  |m 1214267211:Bouffleur, Frederic  |d 910000  |d 910800  |e 910000PB1214267211  |e 910800PB1214267211  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 1106415639  |a Kühle, Reinald  |m 1106415639:Kühle, Reinald  |d 910000  |d 910800  |e 910000PK1106415639  |e 910800PK1106415639  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1241845387  |a Hodecker, Lutz  |m 1241845387:Hodecker, Lutz  |d 910000  |d 910800  |e 910000PH1241845387  |e 910800PH1241845387  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1851794557  |e 4348664870 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Lutz D. Hodecker, Reinald Kuehle, Frederic Weichel, Christoph J. Roser, Christopher J. Lux and Carolien A.J. Bauer"]},"language":["eng"],"recId":"1851794557","person":[{"family":"Hodecker","role":"aut","display":"Hodecker, Lutz","given":"Lutz"},{"family":"Kühle","role":"aut","display":"Kühle, Reinald","given":"Reinald"},{"family":"Bouffleur","role":"aut","given":"Frederic","display":"Bouffleur, Frederic"},{"family":"Roser","role":"aut","given":"Christoph","display":"Roser, Christoph"},{"given":"Christopher J.","display":"Lux, Christopher J.","family":"Lux","role":"aut"},{"family":"Scheurer","role":"aut","given":"Carolien A. J.","display":"Scheurer, Carolien A. J."}],"note":["Gesehen am 05.07.2023"],"title":[{"title_sort":"Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process","title":"Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process","subtitle":"the MIRA appliance"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1851794557"],"doi":["10.3390/bioengineering10050616"]},"physDesc":[{"extent":"12 S."}],"relHost":[{"origin":[{"dateIssuedKey":"2014","publisherPlace":"Basel","publisher":"MDPI","dateIssuedDisp":"2014-"}],"title":[{"title_sort":"Bioengineering","title":"Bioengineering","subtitle":"open access journal"}],"id":{"zdb":["2746191-9"],"eki":["774814020"],"issn":["2306-5354"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"774814020","disp":"Concept for the treatment of Class III anomalies with a skeletally anchored appliance fabricated in the CAD/CAM process the MIRA applianceBioengineering","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 20.05.2020"],"pubHistory":["1.2014 -"],"language":["eng"],"part":{"volume":"10","year":"2023","text":"10(2023), 5, Artikel-ID 616, Seite 1-12","extent":"12","pages":"1-12","issue":"5"}}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"19 May 2023"}]} 
SRT |a HODECKERLUCONCEPTFOR1920