Recharge PSYCH: a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders

Background - Rechargeable implantable pulse generators (r-IPGs) for deep brain stimulation (DBS) promise longer battery life and fewer replacement surgeries versus non-rechargeable systems. Long-term data on the effects of recharging in patients who received DBS for psychiatric indications is limite...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jakobs, Martin (VerfasserIn) , Hajiabadi, Mohammad Mehdi (VerfasserIn) , Aguirre-Padilla, David Hernán (VerfasserIn) , Giaccobe, Peter (VerfasserIn) , Unterberg, Andreas (VerfasserIn) , Lozano, Andres M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 9 February 2023
In: World neurosurgery
Year: 2023, Jahrgang: 170, Pages: e331-e339
ISSN:1878-8769
DOI:10.1016/j.wneu.2022.11.017
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.wneu.2022.11.017
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1878875022015595
Volltext
Verfasserangaben:Martin Jakobs, Mohammad Mehdi Hajiabadi, David Hernán Aguirre-Padilla, Peter Giaccobe, Andreas W. Unterberg, Andres M. Lozano

MARC

LEADER 00000caa a2200000 c 4500
001 1851797890
003 DE-627
005 20240328080825.0
007 cr uuu---uuuuu
008 230705s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.wneu.2022.11.017  |2 doi 
035 |a (DE-627)1851797890 
035 |a (DE-599)KXP1851797890 
035 |a (OCoLC)1389527778 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jakobs, Martin  |d 1985-  |e VerfasserIn  |0 (DE-588)1050384962  |0 (DE-627)78392092X  |0 (DE-576)404578756  |4 aut 
245 1 0 |a Recharge PSYCH  |b a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders  |c Martin Jakobs, Mohammad Mehdi Hajiabadi, David Hernán Aguirre-Padilla, Peter Giaccobe, Andreas W. Unterberg, Andres M. Lozano 
264 1 |c 9 February 2023 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 9. November 2022, Artikelversion 9. Februar 2023 
500 |a Gesehen am 05.07.2023 
520 |a Background - Rechargeable implantable pulse generators (r-IPGs) for deep brain stimulation (DBS) promise longer battery life and fewer replacement surgeries versus non-rechargeable systems. Long-term data on the effects of recharging in patients who received DBS for psychiatric indications is limited. The Recharge PSYCH trial is the first study that included DBS patients with psychiatric disorders treated with different r-IPG models. - Methods - Standardized questionnaires were sent to all psychiatric DBS patients with an r-IPG implanted at the time of the study. The primary endpoint was convenience of recharging. Secondary endpoints were rate of user confidence and rate of usage-related complications, as well as charge burden (defined as minutes per week needed to recharge). - Results - Data sets of n = 21 patients were eligible for data analysis. At the time of the survey patients were implanted with the r-IPG for a mean 31.8 ± 22.4 months. Prior to being implanted with an r-IPG, patients had undergone a median of 3 IPG replacements. The overall convenience of the charging process was rated as "easy" with a median of 8.0 out of 10.0 points. 33.3% of patients experienced situations in which the device could not be successfully recharged. In 38.1% of patients, therapy with the r-IPG was interrupted unintentionally. The average charge burden was 286 ± 22.4 minutes per week. - Conclusions - Patients with psychiatric disorders rated the recharging process as “easy”, but with a significantly higher charge burden and usage-related complication rates compared to published data on movement disorder DBS patients. 
650 4 |a Deep brain stimulation 
650 4 |a Implantable pulse generator 
650 4 |a Psychiatric disorder 
650 4 |a Questionnaire-based 
650 4 |a Rechargeable pulse generators 
700 1 |a Hajiabadi, Mohammad Mehdi  |e VerfasserIn  |0 (DE-588)1212532465  |0 (DE-627)1702043991  |4 aut 
700 1 |a Aguirre-Padilla, David Hernán  |e VerfasserIn  |4 aut 
700 1 |a Giaccobe, Peter  |e VerfasserIn  |4 aut 
700 1 |a Unterberg, Andreas  |e VerfasserIn  |0 (DE-588)1032681187  |0 (DE-627)738641200  |0 (DE-576)168441233  |4 aut 
700 1 |a Lozano, Andres M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t World neurosurgery  |d Amsterdam : Elsevier, 2010  |g 170(2023) vom: Feb., Seite e331-e339  |h Online-Ressource  |w (DE-627)615134904  |w (DE-600)2530041-6  |w (DE-576)321461150  |x 1878-8769  |7 nnas  |a Recharge PSYCH a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders 
773 1 8 |g volume:170  |g year:2023  |g month:02  |g pages:e331-e339  |g extent:9  |a Recharge PSYCH a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders 
856 4 0 |u https://doi.org/10.1016/j.wneu.2022.11.017  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1878875022015595  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230705 
993 |a Article 
994 |a 2023 
998 |g 1032681187  |a Unterberg, Andreas  |m 1032681187:Unterberg, Andreas  |d 910000  |d 911200  |e 910000PU1032681187  |e 911200PU1032681187  |k 0/910000/  |k 1/910000/911200/  |p 5 
998 |g 1212532465  |a Hajiabadi, Mohammad Mehdi  |m 1212532465:Hajiabadi, Mohammad Mehdi  |d 910000  |d 911200  |e 910000PH1212532465  |e 911200PH1212532465  |k 0/910000/  |k 1/910000/911200/  |p 2 
998 |g 1050384962  |a Jakobs, Martin  |m 1050384962:Jakobs, Martin  |d 910000  |d 911200  |d 50000  |e 910000PJ1050384962  |e 911200PJ1050384962  |e 50000PJ1050384962  |k 0/910000/  |k 1/910000/911200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1851797890  |e 434867292X 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Martin Jakobs, Mohammad Mehdi Hajiabadi, David Hernán Aguirre-Padilla, Peter Giaccobe, Andreas W. Unterberg, Andres M. Lozano"]},"id":{"eki":["1851797890"],"doi":["10.1016/j.wneu.2022.11.017"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"9 February 2023"}],"person":[{"display":"Jakobs, Martin","role":"aut","given":"Martin","family":"Jakobs"},{"display":"Hajiabadi, Mohammad Mehdi","role":"aut","given":"Mohammad Mehdi","family":"Hajiabadi"},{"display":"Aguirre-Padilla, David Hernán","family":"Aguirre-Padilla","role":"aut","given":"David Hernán"},{"display":"Giaccobe, Peter","family":"Giaccobe","role":"aut","given":"Peter"},{"family":"Unterberg","given":"Andreas","role":"aut","display":"Unterberg, Andreas"},{"display":"Lozano, Andres M.","family":"Lozano","role":"aut","given":"Andres M."}],"relHost":[{"id":{"issn":["1878-8769"],"eki":["615134904"],"zdb":["2530041-6"]},"title":[{"title_sort":"World neurosurgery","title":"World neurosurgery"}],"part":{"volume":"170","text":"170(2023) vom: Feb., Seite e331-e339","extent":"9","pages":"e331-e339","year":"2023"},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 20.03.25"],"origin":[{"publisherPlace":"Amsterdam","dateIssuedKey":"2010","dateIssuedDisp":"2010-","publisher":"Elsevier"}],"pubHistory":["73.2010 -"],"disp":"Recharge PSYCH a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disordersWorld neurosurgery","recId":"615134904","physDesc":[{"extent":"Online-Ressource"}]}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Online verfügbar 9. November 2022, Artikelversion 9. Februar 2023","Gesehen am 05.07.2023"],"title":[{"title":"Recharge PSYCH","title_sort":"Recharge PSYCH","subtitle":"a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders"}],"physDesc":[{"extent":"9 S."}],"recId":"1851797890"} 
SRT |a JAKOBSMARTRECHARGEPS9202