Clinical application of ultrahigh-field-strength wrist MRI: a multireader 3-T and 7-T comparison study

Background - - Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. - - Purpose - - To compare...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Heiß, Rafael (VerfasserIn) , Weber, Marc-André (VerfasserIn) , Balbach, Eva (VerfasserIn) , Schmitt, Rainer (VerfasserIn) , Rehnitz, Christoph (VerfasserIn) , Laqmani, Azien (VerfasserIn) , Sternberg, Andreas (VerfasserIn) , Ellermann, Jutta J. (VerfasserIn) , Nagel, Armin Michael (VerfasserIn) , Ladd, Mark E. (VerfasserIn) , Englbrecht, Matthias (VerfasserIn) , Arkudas, Andreas (VerfasserIn) , Horch, Raymund (VerfasserIn) , Guermazi, Ali (VerfasserIn) , Uder, Michael (VerfasserIn) , Roemer, Frank W. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: February 10, 2023
In: Radiology
Year: 2023, Jahrgang: 307, Heft: 2, Pages: 1-8
ISSN:1527-1315
DOI:10.1148/radiol.220753
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1148/radiol.220753
Verlag, lizenzpflichtig, Volltext: https://pubs.rsna.org/doi/10.1148/radiol.220753
Volltext
Verfasserangaben:Rafael Heiss, Marc-André Weber, Eva Balbach, Rainer Schmitt, Christoph Rehnitz, Azien Laqmani, Andreas Sternberg, Jutta J. Ellermann, Armin M. Nagel, Mark E. Ladd, Matthias Englbrecht, Andreas Arkudas, Raymund Horch, Ali Guermazi, Michael Uder, Frank W. Roemer

MARC

LEADER 00000caa a2200000 c 4500
001 1852157607
003 DE-627
005 20251020093033.0
007 cr uuu---uuuuu
008 230707s2023 xx |||||o 00| ||eng c
024 7 |a 10.1148/radiol.220753  |2 doi 
035 |a (DE-627)1852157607 
035 |a (DE-599)KXP1852157607 
035 |a (OCoLC)1425215176 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Heiß, Rafael  |d 1987-  |e VerfasserIn  |0 (DE-588)108169615X  |0 (DE-627)846491303  |0 (DE-576)454682182  |4 aut 
245 1 0 |a Clinical application of ultrahigh-field-strength wrist MRI  |b a multireader 3-T and 7-T comparison study  |c Rafael Heiss, Marc-André Weber, Eva Balbach, Rainer Schmitt, Christoph Rehnitz, Azien Laqmani, Andreas Sternberg, Jutta J. Ellermann, Armin M. Nagel, Mark E. Ladd, Matthias Englbrecht, Andreas Arkudas, Raymund Horch, Ali Guermazi, Michael Uder, Frank W. Roemer 
264 1 |c February 10, 2023 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 07.07.2023 
520 |a Background - - Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. - - Purpose - - To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. - - Materials and Methods - - In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. - - Results - - In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). - - Conclusion - - A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. 
700 1 |a Weber, Marc-André  |d 1973-  |e VerfasserIn  |0 (DE-588)142373044  |0 (DE-627)704211432  |0 (DE-576)330376802  |4 aut 
700 1 |a Balbach, Eva  |e VerfasserIn  |4 aut 
700 1 |a Schmitt, Rainer  |e VerfasserIn  |4 aut 
700 1 |a Rehnitz, Christoph  |d 1976-  |e VerfasserIn  |0 (DE-588)140996990  |0 (DE-627)62381627X  |0 (DE-576)321717368  |4 aut 
700 1 |a Laqmani, Azien  |e VerfasserIn  |4 aut 
700 1 |a Sternberg, Andreas  |e VerfasserIn  |4 aut 
700 1 |a Ellermann, Jutta J.  |e VerfasserIn  |4 aut 
700 1 |a Nagel, Armin Michael  |e VerfasserIn  |0 (DE-588)13791878X  |0 (DE-627)598153276  |0 (DE-576)305872141  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Englbrecht, Matthias  |e VerfasserIn  |4 aut 
700 1 |a Arkudas, Andreas  |e VerfasserIn  |4 aut 
700 1 |a Horch, Raymund  |e VerfasserIn  |4 aut 
700 1 |a Guermazi, Ali  |e VerfasserIn  |4 aut 
700 1 |a Uder, Michael  |d 1966-  |e VerfasserIn  |0 (DE-588)173034667  |0 (DE-627)697959368  |0 (DE-576)133887472  |4 aut 
700 1 |a Roemer, Frank W.  |d 1969-  |e VerfasserIn  |0 (DE-588)115665056  |0 (DE-627)691492751  |0 (DE-576)290007755  |4 aut 
773 0 8 |i Enthalten in  |t Radiology  |d Oak Brook, Ill. : Soc., 1923  |g 307(2023), 2 vom: Feb., Artikel-ID e220753, Seite 1-8  |h Online-Ressource  |w (DE-627)320487253  |w (DE-600)2010588-5  |w (DE-576)094056706  |x 1527-1315  |7 nnas  |a Clinical application of ultrahigh-field-strength wrist MRI a multireader 3-T and 7-T comparison study 
773 1 8 |g volume:307  |g year:2023  |g number:2  |g month:02  |g elocationid:e220753  |g pages:1-8  |g extent:8  |a Clinical application of ultrahigh-field-strength wrist MRI a multireader 3-T and 7-T comparison study 
856 4 0 |u https://doi.org/10.1148/radiol.220753  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://pubs.rsna.org/doi/10.1148/radiol.220753  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230707 
993 |a Article 
994 |a 2023 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |e 130000PL108120964X  |k 0/130000/  |p 10 
998 |g 13791878X  |a Nagel, Armin Michael  |m 13791878X:Nagel, Armin Michael  |p 9 
998 |g 140996990  |a Rehnitz, Christoph  |m 140996990:Rehnitz, Christoph  |d 910000  |d 911400  |d 50000  |e 910000PR140996990  |e 911400PR140996990  |e 50000PR140996990  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 5 
998 |g 142373044  |a Weber, Marc-André  |m 142373044:Weber, Marc-André  |d 50000  |e 50000PW142373044  |k 0/50000/  |p 2 
999 |a KXP-PPN1852157607  |e 4349621881 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Heiß","display":"Heiß, Rafael","roleDisplay":"VerfasserIn","role":"aut","given":"Rafael"},{"roleDisplay":"VerfasserIn","display":"Weber, Marc-André","family":"Weber","given":"Marc-André","role":"aut"},{"role":"aut","given":"Eva","roleDisplay":"VerfasserIn","family":"Balbach","display":"Balbach, Eva"},{"roleDisplay":"VerfasserIn","family":"Schmitt","display":"Schmitt, Rainer","given":"Rainer","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Rehnitz, Christoph","family":"Rehnitz","role":"aut","given":"Christoph"},{"role":"aut","given":"Azien","family":"Laqmani","display":"Laqmani, Azien","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Andreas","display":"Sternberg, Andreas","family":"Sternberg","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Jutta J.","roleDisplay":"VerfasserIn","display":"Ellermann, Jutta J.","family":"Ellermann"},{"given":"Armin Michael","role":"aut","family":"Nagel","display":"Nagel, Armin Michael","roleDisplay":"VerfasserIn"},{"given":"Mark E.","role":"aut","display":"Ladd, Mark E.","family":"Ladd","roleDisplay":"VerfasserIn"},{"given":"Matthias","role":"aut","display":"Englbrecht, Matthias","family":"Englbrecht","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Andreas","family":"Arkudas","display":"Arkudas, Andreas","roleDisplay":"VerfasserIn"},{"given":"Raymund","role":"aut","roleDisplay":"VerfasserIn","family":"Horch","display":"Horch, Raymund"},{"roleDisplay":"VerfasserIn","display":"Guermazi, Ali","family":"Guermazi","role":"aut","given":"Ali"},{"given":"Michael","role":"aut","family":"Uder","display":"Uder, Michael","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Roemer","display":"Roemer, Frank W.","role":"aut","given":"Frank W."}],"title":[{"title":"Clinical application of ultrahigh-field-strength wrist MRI","subtitle":"a multireader 3-T and 7-T comparison study","title_sort":"Clinical application of ultrahigh-field-strength wrist MRI"}],"note":["Gesehen am 07.07.2023"],"recId":"1852157607","physDesc":[{"extent":"8 S."}],"id":{"doi":["10.1148/radiol.220753"],"eki":["1852157607"]},"language":["eng"],"relHost":[{"corporate":[{"role":"isb","display":"Radiological Society of North America","roleDisplay":"Herausgebendes Organ"}],"part":{"year":"2023","text":"307(2023), 2 vom: Feb., Artikel-ID e220753, Seite 1-8","extent":"8","issue":"2","volume":"307","pages":"1-8"},"name":{"displayForm":["The Radiological Society of North America"]},"pubHistory":["1.1923 -"],"disp":"Clinical application of ultrahigh-field-strength wrist MRI a multireader 3-T and 7-T comparison studyRadiology","origin":[{"publisherPlace":"Oak Brook, Ill.","dateIssuedKey":"1923","publisher":"Soc.","dateIssuedDisp":"1923-"}],"title":[{"title_sort":"Radiology","title":"Radiology"}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen 07.11.22"],"type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["320487253"],"issn":["1527-1315"],"zdb":["2010588-5"]},"language":["eng"],"recId":"320487253"}],"name":{"displayForm":["Rafael Heiss, Marc-André Weber, Eva Balbach, Rainer Schmitt, Christoph Rehnitz, Azien Laqmani, Andreas Sternberg, Jutta J. Ellermann, Armin M. Nagel, Mark E. Ladd, Matthias Englbrecht, Andreas Arkudas, Raymund Horch, Ali Guermazi, Michael Uder, Frank W. Roemer"]},"origin":[{"dateIssuedDisp":"February 10, 2023","dateIssuedKey":"2023"}]} 
SRT |a HEISSRAFAECLINICALAP1020