Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging

Objectives - To apply a navigator-based slice tracking method to prospectively compensate the respiratory motion for kidney vessel architecture imaging (VAI). - Materials and methods - A dual gradient echo spin echo 2D EPI sequence was developed for kidney VAI. A single gradient-echo slice selection...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, Ke (Author) , Triphan, Simon M. F. (Author) , Kurz, Felix T. (Author) , Ziener, Christian H. (Author) , Kauczor, Hans-Ulrich (Author) , Schlemmer, Heinz-Peter (Author) , Sedlaczek, Oliver (Author)
Format: Article (Journal)
Language:English
Published: 14 January 2023
In: Magnetic resonance imaging
Year: 2023, Volume: 98, Pages: 26-35
ISSN:1873-5894
DOI:10.1016/j.mri.2023.01.001
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.mri.2023.01.001
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X23000012
Get full text
Author Notes:Ke Zhang, Simon M.F. Triphan, Felix T. Kurz, Christian H. Ziener, Hans-Ulrich Kauczor, Heinz-Peter Schlemmer, Oliver Sedlaczek

MARC

LEADER 00000caa a2200000 c 4500
001 1852226420
003 DE-627
005 20240307074140.0
007 cr uuu---uuuuu
008 230710s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.mri.2023.01.001  |2 doi 
035 |a (DE-627)1852226420 
035 |a (DE-599)KXP1852226420 
035 |a (OCoLC)1425214930 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zhang, Ke  |d 1984-  |e VerfasserIn  |0 (DE-588)142064564  |0 (DE-627)704133199  |0 (DE-576)327160438  |4 aut 
245 1 0 |a Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging  |c Ke Zhang, Simon M.F. Triphan, Felix T. Kurz, Christian H. Ziener, Hans-Ulrich Kauczor, Heinz-Peter Schlemmer, Oliver Sedlaczek 
264 1 |c 14 January 2023 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 2 January 2023, Version des Artikels 14 January 2023 
500 |a Gesehen am 10.07.2023 
520 |a Objectives - To apply a navigator-based slice tracking method to prospectively compensate the respiratory motion for kidney vessel architecture imaging (VAI). - Materials and methods - A dual gradient echo spin echo 2D EPI sequence was developed for kidney VAI. A single gradient-echo slice selection and projection readout at the location of the diaphragm along the inferior-superior direction was applied as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice. Motion information was calculated after exclusion of the signal saturation in the navigator signal caused by imaging slices. The motion information was then directly sent back to the sequence and slice positioning was adjusted in real-time. The whole sequence was applied during a contrast agent pass-through. - Results - VAI parametric maps show the structural heterogeneity of the renal vasculature. The respiratory motion from the navigator signal was precisely calculated and slice positioning was changed in real-time based on the motion information. The vibration amplitude of the signal intensity of the liver tissue at the liver-lung interface in the case of prospective motion correction (PMC) on is about 28% of the PMC off case. Compared to the case of PMC off, the coefficient of variation was reduced 30% of the case of PMC on. - Conclusions - This study demonstrates the feasibility of the motion-compensating technique in kidney VAI. The sequence may improve the evaluation of microvasculature in kidney diseases. 
650 4 |a Kidney, prospective motion correction 
650 4 |a Vessel architecture imaging 
700 1 |a Triphan, Simon M. F.  |e VerfasserIn  |0 (DE-588)1072565080  |0 (DE-627)827729553  |0 (DE-576)434034207  |4 aut 
700 1 |a Kurz, Felix T.  |d 1981-  |e VerfasserIn  |0 (DE-588)1043285474  |0 (DE-627)771321066  |0 (DE-576)394610342  |4 aut 
700 1 |a Ziener, Christian H.  |d 1978-  |e VerfasserIn  |0 (DE-588)137982755  |0 (DE-627)59885309X  |0 (DE-576)306117355  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Sedlaczek, Oliver  |d 1970-  |e VerfasserIn  |0 (DE-588)123144493  |0 (DE-627)706179838  |0 (DE-576)293576173  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance imaging  |d Amsterdam [u.a.] : Elsevier Science, 1982  |g 98(2023) vom: Mai, Seite 26-35  |h Online-Ressource  |w (DE-627)306661160  |w (DE-600)1500646-3  |w (DE-576)081986750  |x 1873-5894  |7 nnas  |a Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging 
773 1 8 |g volume:98  |g year:2023  |g month:05  |g pages:26-35  |g extent:10  |a Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging 
856 4 0 |u https://doi.org/10.1016/j.mri.2023.01.001  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0730725X23000012  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230710 
993 |a Article 
994 |a 2023 
998 |g 123144493  |a Sedlaczek, Oliver  |m 123144493:Sedlaczek, Oliver  |d 910000  |d 911400  |d 50000  |e 910000PS123144493  |e 911400PS123144493  |e 50000PS123144493  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 7  |y j 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 6 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |d 50000  |e 910000PK139267123  |e 911400PK139267123  |e 50000PK139267123  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 5 
998 |g 137982755  |a Ziener, Christian H.  |m 137982755:Ziener, Christian H.  |d 50000  |e 50000PZ137982755  |k 0/50000/  |p 4 
998 |g 1043285474  |a Kurz, Felix T.  |m 1043285474:Kurz, Felix T.  |d 50000  |e 50000PK1043285474  |k 0/50000/  |p 3 
998 |g 1072565080  |a Triphan, Simon M. F.  |m 1072565080:Triphan, Simon M. F.  |d 910000  |d 911400  |e 910000PT1072565080  |e 911400PT1072565080  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 142064564  |a Zhang, Ke  |m 142064564:Zhang, Ke  |d 910000  |d 911400  |d 50000  |e 910000PZ142064564  |e 911400PZ142064564  |e 50000PZ142064564  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1852226420  |e 4351673338 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"display":"Zhang, Ke","family":"Zhang","role":"aut","given":"Ke"},{"family":"Triphan","display":"Triphan, Simon M. F.","role":"aut","given":"Simon M. F."},{"role":"aut","given":"Felix T.","display":"Kurz, Felix T.","family":"Kurz"},{"family":"Ziener","display":"Ziener, Christian H.","role":"aut","given":"Christian H."},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","given":"Hans-Ulrich","role":"aut"},{"family":"Schlemmer","display":"Schlemmer, Heinz-Peter","role":"aut","given":"Heinz-Peter"},{"role":"aut","given":"Oliver","display":"Sedlaczek, Oliver","family":"Sedlaczek"}],"physDesc":[{"extent":"10 S."}],"name":{"displayForm":["Ke Zhang, Simon M.F. Triphan, Felix T. Kurz, Christian H. Ziener, Hans-Ulrich Kauczor, Heinz-Peter Schlemmer, Oliver Sedlaczek"]},"relHost":[{"note":["Gesehen am 29.01.2020"],"origin":[{"dateIssuedKey":"1982","publisher":"Elsevier Science","dateIssuedDisp":"1982-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["1.1982 -"],"title":[{"title_sort":"Magnetic resonance imaging","subtitle":"an international journal of basic research and clinical applications","title":"Magnetic resonance imaging"}],"disp":"Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imagingMagnetic resonance imaging","type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"306661160","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["306661160"],"zdb":["1500646-3"],"issn":["1873-5894"]},"language":["eng"],"part":{"extent":"10","text":"98(2023) vom: Mai, Seite 26-35","volume":"98","pages":"26-35","year":"2023"}}],"recId":"1852226420","id":{"eki":["1852226420"],"doi":["10.1016/j.mri.2023.01.001"]},"title":[{"title":"Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging","title_sort":"Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging"}],"note":["Online verfügbar 2 January 2023, Version des Artikels 14 January 2023","Gesehen am 10.07.2023"],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"14 January 2023"}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a ZHANGKETRINAVIGATORB1420