Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography

Purpose - The Histolog® Scanner (SamanTree Medical SA, Lausanne, Switzerland) is a large field-of-view confocal laser scanning microscope designed to allow intraoperative margin assessment by the production of histological images ready for assessment in the operating room. We evaluated the feasibili...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Togawa, Riku (VerfasserIn) , Hederer, Johanna (VerfasserIn) , Ragazzi, Moira (VerfasserIn) , Bruckner, Thomas (VerfasserIn) , Fastner, Sarah (VerfasserIn) , Gomez, Christina (VerfasserIn) , Hennigs, André (VerfasserIn) , Nees, Juliane (VerfasserIn) , Pfob, André (VerfasserIn) , Riedel, Fabian (VerfasserIn) , Schäfgen, Benedikt (VerfasserIn) , Stieber, Anne (VerfasserIn) , Lux, Michael P. (VerfasserIn) , Heil, Jörg (VerfasserIn) , Golatta, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 February 2023
In: The breast
Year: 2023, Jahrgang: 68, Pages: 194-200
ISSN:1532-3080
DOI:10.1016/j.breast.2023.02.010
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.breast.2023.02.010
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0960977623000334
Volltext
Verfasserangaben:Riku Togawa, Johanna Hederer, Moira Ragazzi, Thomas Bruckner, Sarah Fastner, Christina Gomez, André Hennigs, Juliane Nees, André Pfob, Fabian Riedel, Benedikt Schäfgen, Anne Stieber, Michael P. Lux, Jörg Heil, Michael Golatta

MARC

LEADER 00000caa a2200000 c 4500
001 1852456612
003 DE-627
005 20240328080918.0
007 cr uuu---uuuuu
008 230712s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.breast.2023.02.010  |2 doi 
035 |a (DE-627)1852456612 
035 |a (DE-599)KXP1852456612 
035 |a (OCoLC)1425215046 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Togawa, Riku  |d 1992-  |e VerfasserIn  |0 (DE-588)1176840371  |0 (DE-627)1048211711  |0 (DE-576)516872478  |4 aut 
245 1 0 |a Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography  |c Riku Togawa, Johanna Hederer, Moira Ragazzi, Thomas Bruckner, Sarah Fastner, Christina Gomez, André Hennigs, Juliane Nees, André Pfob, Fabian Riedel, Benedikt Schäfgen, Anne Stieber, Michael P. Lux, Jörg Heil, Michael Golatta 
264 1 |c 24 February 2023 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 22 February 2023, Version des Artikels 24 February 2023 
500 |a Gesehen am 12.07.2023 
520 |a Purpose - The Histolog® Scanner (SamanTree Medical SA, Lausanne, Switzerland) is a large field-of-view confocal laser scanning microscope designed to allow intraoperative margin assessment by the production of histological images ready for assessment in the operating room. We evaluated the feasibility and the performance of the Histolog® Scanner (HS) to correctly identify infiltrated margins in clinical practice of lumpectomy specimens. It was extrapolated if the utilization of the HS has the potential to reduce infiltrated margins and therefore reduce re-operation rates in patients undergoing breast conserving surgery (BCS) due to a primarily diagnosed breast cancer including ductal carcinoma in situ. - Methods - This is a single-center, prospective, non-interventional, diagnostic pilot study including 50 consecutive patients receiving BCS. The complete surface of the specimen was scanned using the HS intraoperatively. The surgery and the intraoperative margin assessment of the specimen was performed according to the clinical routine consisting of conventional specimen radiography as well as the clinical impression of the surgeon. Three surgeons and an experienced pathologist assessed the scans produced by the HS for cancer cells on the surface. The potential of the HS to correctly identify involved margins was compared to the results of the conventional specimen radiography alone as well as the clinical routine. The histopathological report served as the gold standard. - Results - 50 specimens corresponding to 300 surfaces were scanned by the HS. The mean sensitivity of the surgeons to identify involved margins with the HS was 37.5% ± 5.6%, the specificity was 75.2% ± 13.0%. The assessment of resection margins by the pathologist resulted in a sensitivity of 37.5% and a specificity of 81.0%, while the local clinical routine resulted in a sensitivity of 37.5% and a specificity of 78.2%. - Conclusion - Acquisition of high-resolution histological images using the HS was feasible in clinical practice. Sensitivity and specificity were comparable to clinical routine. With more specific training and experience on image interpretation and acquisition, the HS may have the potential to enable more accuracy in the margin assessment of BCS specimens. 
650 4 |a Breast cancer 
650 4 |a Breast conserving surgery 
650 4 |a Confocal microscopy 
650 4 |a Conventional specimen radiography 
650 4 |a Fresh tissue imaging 
650 4 |a Margin assessment 
700 1 |a Hederer, Johanna  |e VerfasserIn  |4 aut 
700 1 |a Ragazzi, Moira  |e VerfasserIn  |4 aut 
700 1 |a Bruckner, Thomas  |d 1956-  |e VerfasserIn  |0 (DE-588)136046215  |0 (DE-627)574429298  |0 (DE-576)300798768  |4 aut 
700 1 |a Fastner, Sarah  |d 1986-  |e VerfasserIn  |0 (DE-588)1133023819  |0 (DE-627)888168640  |0 (DE-576)489054390  |4 aut 
700 1 |a Gomez, Christina  |e VerfasserIn  |0 (DE-588)1140871358  |0 (DE-627)898745012  |0 (DE-576)494108444  |4 aut 
700 1 |a Hennigs, André  |e VerfasserIn  |0 (DE-588)1077795238  |0 (DE-627)837512395  |0 (DE-576)446682780  |4 aut 
700 1 |a Nees, Juliane  |d 1989-  |e VerfasserIn  |0 (DE-588)108222295X  |0 (DE-627)84721270X  |0 (DE-576)455206988  |4 aut 
700 1 |a Pfob, André  |e VerfasserIn  |0 (DE-588)1167798945  |0 (DE-627)1031607064  |0 (DE-576)51127338X  |4 aut 
700 1 |a Riedel, Fabian  |d 1987-  |e VerfasserIn  |0 (DE-588)1117048381  |0 (DE-627)870923951  |0 (DE-576)478697007  |4 aut 
700 1 |a Schäfgen, Benedikt  |d 1989-  |e VerfasserIn  |0 (DE-588)1125143754  |0 (DE-627)879456183  |0 (DE-576)483340790  |4 aut 
700 1 |a Stieber, Anne  |e VerfasserIn  |0 (DE-588)111704873X  |0 (DE-627)870924613  |0 (DE-576)478697228  |4 aut 
700 1 |a Lux, Michael P.  |e VerfasserIn  |4 aut 
700 1 |a Heil, Jörg  |d 1978-  |e VerfasserIn  |0 (DE-588)132580187  |0 (DE-627)52396160X  |0 (DE-576)299238679  |4 aut 
700 1 |a Golatta, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)132350386  |0 (DE-627)521535727  |0 (DE-576)299091392  |4 aut 
773 0 8 |i Enthalten in  |t The breast  |d Amsterdam [u.a.] : Elsevier, 1992  |g 68(2023) vom: Apr., Seite 194-200  |h Online-Ressource  |w (DE-627)320475042  |w (DE-600)2009043-2  |w (DE-576)103868151  |x 1532-3080  |7 nnas  |a Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography 
773 1 8 |g volume:68  |g year:2023  |g month:04  |g pages:194-200  |g extent:7  |a Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography 
856 4 0 |u https://doi.org/10.1016/j.breast.2023.02.010  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0960977623000334  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230712 
993 |a Article 
994 |a 2023 
998 |g 132350386  |a Golatta, Michael  |m 132350386:Golatta, Michael  |d 910000  |d 910400  |d 50000  |e 910000PG132350386  |e 910400PG132350386  |e 50000PG132350386  |k 0/910000/  |k 1/910000/910400/  |k 0/50000/  |p 15 
998 |g 132580187  |a Heil, Jörg  |m 132580187:Heil, Jörg  |d 910000  |d 910400  |d 50000  |e 910000PH132580187  |e 910400PH132580187  |e 50000PH132580187  |k 0/910000/  |k 1/910000/910400/  |k 0/50000/  |p 14 
998 |g 111704873X  |a Stieber, Anne  |m 111704873X:Stieber, Anne  |d 910000  |d 911400  |e 910000PS111704873X  |e 911400PS111704873X  |k 0/910000/  |k 1/910000/911400/  |p 12 
998 |g 1125143754  |a Schäfgen, Benedikt  |m 1125143754:Schäfgen, Benedikt  |d 910000  |d 910400  |e 910000PS1125143754  |e 910400PS1125143754  |k 0/910000/  |k 1/910000/910400/  |p 11 
998 |g 1117048381  |a Riedel, Fabian  |m 1117048381:Riedel, Fabian  |d 910000  |d 910400  |e 910000PR1117048381  |e 910400PR1117048381  |k 0/910000/  |k 1/910000/910400/  |p 10 
998 |g 1167798945  |a Pfob, André  |m 1167798945:Pfob, André  |d 910000  |d 910400  |e 910000PP1167798945  |e 910400PP1167798945  |k 0/910000/  |k 1/910000/910400/  |p 9 
998 |g 108222295X  |a Nees, Juliane  |m 108222295X:Nees, Juliane  |d 910000  |d 910400  |e 910000PN108222295X  |e 910400PN108222295X  |k 0/910000/  |k 1/910000/910400/  |p 8 
998 |g 1077795238  |a Hennigs, André  |m 1077795238:Hennigs, André  |d 50000  |e 50000PH1077795238  |k 0/50000/  |p 7 
998 |g 1140871358  |a Gomez, Christina  |m 1140871358:Gomez, Christina  |p 6 
998 |g 1133023819  |a Fastner, Sarah  |m 1133023819:Fastner, Sarah  |p 5 
998 |g 136046215  |a Bruckner, Thomas  |m 136046215:Bruckner, Thomas  |d 50000  |e 50000PB136046215  |k 0/50000/  |p 4 
998 |g 1176840371  |a Togawa, Riku  |m 1176840371:Togawa, Riku  |d 910000  |d 910400  |e 910000PT1176840371  |e 910400PT1176840371  |k 0/910000/  |k 1/910000/910400/  |p 1  |x j 
999 |a KXP-PPN1852456612  |e 4352825204 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1016/j.breast.2023.02.010"],"eki":["1852456612"]},"name":{"displayForm":["Riku Togawa, Johanna Hederer, Moira Ragazzi, Thomas Bruckner, Sarah Fastner, Christina Gomez, André Hennigs, Juliane Nees, André Pfob, Fabian Riedel, Benedikt Schäfgen, Anne Stieber, Michael P. Lux, Jörg Heil, Michael Golatta"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"language":["eng"],"part":{"pages":"194-200","year":"2023","volume":"68","extent":"7","text":"68(2023) vom: Apr., Seite 194-200"},"recId":"320475042","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["320475042"],"issn":["1532-3080"],"zdb":["2009043-2"]},"title":[{"title_sort":"breast","title":"The breast"}],"note":["Gesehen am 27.04.2020","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisher":"Elsevier ; Harcourt","dateIssuedKey":"1992","dateIssuedDisp":"1992-","publisherPlace":"Amsterdam [u.a.] ; Burlington, Mass."}],"pubHistory":["1.1992 -"],"disp":"Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiographyThe breast","type":{"media":"Online-Ressource","bibl":"periodical"}}],"recId":"1852456612","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Online verfügbar 22 February 2023, Version des Artikels 24 February 2023","Gesehen am 12.07.2023"],"origin":[{"dateIssuedDisp":"24 February 2023","dateIssuedKey":"2023"}],"title":[{"title_sort":"Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography","title":"Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy ‘Histolog® scanner’ for breast margin assessment in comparison with conventional specimen radiography"}],"language":["eng"],"person":[{"display":"Togawa, Riku","family":"Togawa","given":"Riku","role":"aut"},{"family":"Hederer","display":"Hederer, Johanna","given":"Johanna","role":"aut"},{"given":"Moira","role":"aut","family":"Ragazzi","display":"Ragazzi, Moira"},{"family":"Bruckner","display":"Bruckner, Thomas","given":"Thomas","role":"aut"},{"display":"Fastner, Sarah","family":"Fastner","role":"aut","given":"Sarah"},{"display":"Gomez, Christina","family":"Gomez","role":"aut","given":"Christina"},{"role":"aut","given":"André","family":"Hennigs","display":"Hennigs, André"},{"display":"Nees, Juliane","family":"Nees","role":"aut","given":"Juliane"},{"display":"Pfob, André","family":"Pfob","role":"aut","given":"André"},{"given":"Fabian","role":"aut","family":"Riedel","display":"Riedel, Fabian"},{"family":"Schäfgen","display":"Schäfgen, Benedikt","given":"Benedikt","role":"aut"},{"role":"aut","given":"Anne","family":"Stieber","display":"Stieber, Anne"},{"role":"aut","given":"Michael P.","family":"Lux","display":"Lux, Michael P."},{"role":"aut","given":"Jörg","family":"Heil","display":"Heil, Jörg"},{"display":"Golatta, Michael","family":"Golatta","given":"Michael","role":"aut"}]} 
SRT |a TOGAWARIKUIMAGINGOFL2420