A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction

L5 nerve palsy is a well-known complication following reduction of high-grade spondylolisthesis. While several mechanisms for its occurrence have been proposed, the hypothesis of L5 nerve root strain or displacement secondary to mechanical reduction remains poorly studied. The aim of this cadaveric...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ishak, Basem (VerfasserIn) , Pierre, Clifford A. (VerfasserIn) , Ansari, Darius (VerfasserIn) , Lachkar, Stefan (VerfasserIn) , Glinski, Alexander von (VerfasserIn) , Unterberg, Andreas (VerfasserIn) , Oskouian, Rod J. (VerfasserIn) , Chapman, Jens R. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Neurosurgical review
Year: 2022, Jahrgang: 45, Heft: 2, Pages: 1741-1746
ISSN:1437-2320
DOI:10.1007/s10143-021-01721-z
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s10143-021-01721-z
Volltext
Verfasserangaben:Basem Ishak, Clifford A. Pierre, Darius Ansari, Stefan Lachkar, Alexander von Glinski, Andreas W. Unterberg, Rod J. Oskouian, Jens R. Chapman

MARC

LEADER 00000caa a2200000 c 4500
001 1853774014
003 DE-627
005 20240328081323.0
007 cr uuu---uuuuu
008 230727s2022 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10143-021-01721-z  |2 doi 
035 |a (DE-627)1853774014 
035 |a (DE-599)KXP1853774014 
035 |a (OCoLC)1425062188 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ishak, Basem  |d 1984-  |e VerfasserIn  |0 (DE-588)141959584  |0 (DE-627)632543760  |0 (DE-576)327070528  |4 aut 
245 1 2 |a A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction  |c Basem Ishak, Clifford A. Pierre, Darius Ansari, Stefan Lachkar, Alexander von Glinski, Andreas W. Unterberg, Rod J. Oskouian, Jens R. Chapman 
264 1 |c 2022 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.07.2023 
500 |a Online veröffentlicht am 29 December 2021 
520 |a L5 nerve palsy is a well-known complication following reduction of high-grade spondylolisthesis. While several mechanisms for its occurrence have been proposed, the hypothesis of L5 nerve root strain or displacement secondary to mechanical reduction remains poorly studied. The aim of this cadaveric study is to determine changes in morphologic parameters of the L5 nerve root during simulated intraoperative reduction of high-grade spondylolisthesis. A standard posterior approach to the lumbosacral junction was performed in eight fresh-frozen cadavers with lumbosacral or lumbopelvic screw fixation. Wide decompressions of the spinal canal and L5 nerve roots with complete facetectomies were accomplished with full exposure of the L5 nerve roots. A 100% translational slip was provoked by release of the iliolumbar ligaments and cutting the disc with the attached anterior longitudinal ligament. To evaluate the path of the L5 nerves during reduction maneuvers, metal bars were inserted bilaterally at the inferomedial aspects of the L5 pedicle at a distance of 10 mm from the midpoint of the L5 pedicle screws. There was no measurable change in length of the L5 nerve roots after 50% and 100% reduction of spondylolisthesis. Mechanical strain or displacement during reduction is an unlikely cause of L5 nerve root injury. Further anatomical or physiological studies are necessary to explore alternative mechanisms of L5 nerve palsy in the setting of high-grade spondylolisthesis correction, and surgeons should favor extensive surgical decompression of the L5 nerve roots when feasible. 
650 4 |a Cadaveric study 
650 4 |a L5 nerve palsy 
650 4 |a Reduction 
650 4 |a Spondylolisthesis 
650 4 |a Stretch injury 
700 1 |a Pierre, Clifford A.  |e VerfasserIn  |4 aut 
700 1 |a Ansari, Darius  |e VerfasserIn  |4 aut 
700 1 |a Lachkar, Stefan  |e VerfasserIn  |4 aut 
700 1 |a Glinski, Alexander von  |d 1988-  |e VerfasserIn  |0 (DE-588)1130264122  |0 (DE-627)884601528  |0 (DE-576)486714470  |4 aut 
700 1 |a Unterberg, Andreas  |e VerfasserIn  |0 (DE-588)1032681187  |0 (DE-627)738641200  |0 (DE-576)168441233  |4 aut 
700 1 |a Oskouian, Rod J.  |e VerfasserIn  |0 (DE-588)1175904295  |0 (DE-627)1047028352  |0 (DE-576)516419048  |4 aut 
700 1 |a Chapman, Jens R.  |e VerfasserIn  |0 (DE-588)173353088  |0 (DE-627)674388445  |0 (DE-576)134200500  |4 aut 
773 0 8 |i Enthalten in  |t Neurosurgical review  |d Berlin : Springer, 1978  |g 45(2022), 2, Seite 1741-1746  |h Online-Ressource  |w (DE-627)269533133  |w (DE-600)1474861-7  |w (DE-576)080987060  |x 1437-2320  |7 nnas  |a A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction 
773 1 8 |g volume:45  |g year:2022  |g number:2  |g pages:1741-1746  |g extent:6  |a A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction 
856 4 0 |u https://doi.org/10.1007/s10143-021-01721-z  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230727 
993 |a Article 
994 |a 2022 
998 |g 1032681187  |a Unterberg, Andreas  |m 1032681187:Unterberg, Andreas  |d 910000  |d 911200  |e 910000PU1032681187  |e 911200PU1032681187  |k 0/910000/  |k 1/910000/911200/  |p 6 
998 |g 141959584  |a Ishak, Basem  |m 141959584:Ishak, Basem  |d 910000  |d 911200  |d 50000  |e 910000PI141959584  |e 911200PI141959584  |e 50000PI141959584  |k 0/910000/  |k 1/910000/911200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1853774014  |e 4358173527 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"2022"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"display":"Ishak, Basem","given":"Basem","family":"Ishak","role":"aut"},{"family":"Pierre","given":"Clifford A.","display":"Pierre, Clifford A.","role":"aut"},{"role":"aut","family":"Ansari","given":"Darius","display":"Ansari, Darius"},{"family":"Lachkar","given":"Stefan","display":"Lachkar, Stefan","role":"aut"},{"role":"aut","given":"Alexander von","family":"Glinski","display":"Glinski, Alexander von"},{"display":"Unterberg, Andreas","given":"Andreas","family":"Unterberg","role":"aut"},{"role":"aut","display":"Oskouian, Rod J.","given":"Rod J.","family":"Oskouian"},{"role":"aut","display":"Chapman, Jens R.","given":"Jens R.","family":"Chapman"}],"title":[{"title":"A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction","title_sort":"novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reduction"}],"note":["Gesehen am 27.07.2023","Online veröffentlicht am 29 December 2021"],"name":{"displayForm":["Basem Ishak, Clifford A. Pierre, Darius Ansari, Stefan Lachkar, Alexander von Glinski, Andreas W. Unterberg, Rod J. Oskouian, Jens R. Chapman"]},"relHost":[{"recId":"269533133","id":{"zdb":["1474861-7"],"issn":["1437-2320"],"eki":["269533133"]},"disp":"A novel anatomo-physiologic high-grade spondylolisthesis model to evaluate L5 nerve stretch injury after spondylolisthesis reductionNeurosurgical review","physDesc":[{"extent":"Online-Ressource"}],"part":{"pages":"1741-1746","volume":"45","extent":"6","issue":"2","year":"2022","text":"45(2022), 2, Seite 1741-1746"},"language":["eng"],"title":[{"title":"Neurosurgical review","title_sort":"Neurosurgical review"}],"pubHistory":["1.1978 -"],"origin":[{"dateIssuedKey":"1978","publisherPlace":"Berlin ; Heidelberg ; New York","dateIssuedDisp":"1978-","publisher":"Springer"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 24.11.05","Fortsetzung der Druck-Ausgabe"]}],"recId":"1853774014","id":{"doi":["10.1007/s10143-021-01721-z"],"eki":["1853774014"]},"language":["eng"],"physDesc":[{"extent":"6 S."}]} 
SRT |a ISHAKBASEMNOVELANATO2022