Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia

Purpose - To evaluate the diagnostic accuracy of a novel optical coherence tomography texture-based en face image analysis (SALSA-Texture) that requires segmentation of only 1 retinal layer for glaucoma detection in eyes with axial high myopia, and to compare SALSA-Texture with standard macular gang...

Full description

Saved in:
Bibliographic Details
Main Authors: Bowd, Christopher (Author) , Belghith, Akram (Author) , Rezapour, Jasmin (Author) , Christopher, Mark (Author) , Hyman, Leslie (Author) , Jonas, Jost B. (Author) , Weinreb, Robert N. (Author) , Zangwill, Linda M. (Author)
Format: Article (Journal)
Language:English
Published: 2 May 2022
In: American journal of ophthalmology
Year: 2022, Volume: 242, Pages: 26-35
ISSN:1879-1891
DOI:10.1016/j.ajo.2022.04.019
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ajo.2022.04.019
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0002939422001684
Get full text
Author Notes:Christopher Bowd, Akram Belghith, Jasmin Rezapour, Mark Christopher, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill

MARC

LEADER 00000caa a2200000 c 4500
001 1854026828
003 DE-627
005 20240328081425.0
007 cr uuu---uuuuu
008 230801s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ajo.2022.04.019  |2 doi 
035 |a (DE-627)1854026828 
035 |a (DE-599)KXP1854026828 
035 |a (OCoLC)1425217079 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bowd, Christopher  |e VerfasserIn  |0 (DE-588)1297855191  |0 (DE-627)1854028588  |4 aut 
245 1 0 |a Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia  |c Christopher Bowd, Akram Belghith, Jasmin Rezapour, Mark Christopher, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill 
264 1 |c 2 May 2022 
300 |b Illustrationen 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 2 May 2022, Artikelversion: 9 July 2022 
500 |a Gesehen am 01.08.2023 
520 |a Purpose - To evaluate the diagnostic accuracy of a novel optical coherence tomography texture-based en face image analysis (SALSA-Texture) that requires segmentation of only 1 retinal layer for glaucoma detection in eyes with axial high myopia, and to compare SALSA-Texture with standard macular ganglion cell-inner plexiform layer (GCIPL) thickness, macular retinal nerve fiber layer (mRNFL) thickness, and ganglion cell complex (GCC) thickness maps. - Design - Comparison of diagnostic approaches. - Methods - Cross-sectional data were collected from 92 eyes with primary open-angle glaucoma (POAG) and 44 healthy control eyes with axial high myopia (axial length >26 mm). Optical coherence tomography texture en face images, developed using SALSA-Texture to model the spatial arrangement patterns of the pixel intensities in a region, were generated from 70-μm slabs just below the vitreal border of the inner limiting membrane. Areas under the receiver operating characteristic curves (AUROCs) and areas under the precision recall curves (AUPRCs) adjusted for both eyes, axial length, age, disc area, and image quality were used to compare different approaches. - Results - The best parameter-adjusted AUROCs (95% confidence intervals) for differentiating between healthy and glaucoma high myopic eyes were 0.92 (0.88-0.94) for texture en face images, 0.88 (0.86-0.91) for macular RNFL thickness, 0.87 (0.83-0.89) for macula GCIPL thickness, and 0.87 (0.84-0.89) for GCC thickness. A subset analysis of highly advanced myopic eyes (axial length ≥27 mm; 38 glaucomatous eyes and 22 healthy eyes) showed the best AUROC was 0.92 (0.89-0.94) for texture en face images compared with 0.86 (0.84-0.88) for macular GCIPL, 0.86 (0.84-0.88) for GCC, and 0.84 (0.81-0.87) for RNFL thickness (P ≤ .02 compared with texture for all comparisons). - Conclusion - The current results suggest that our novel en face texture-based analysis method can improve on most investigated macular tissue thickness measurements for discriminating between highly myopic glaucomatous and highly myopic healthy eyes. While further investigation is needed, texture en face images show promise for improving the detection of glaucoma in eyes with high myopia where traditional retinal layer segmentation often is challenging. 
700 1 |a Belghith, Akram  |e VerfasserIn  |4 aut 
700 1 |a Rezapour, Jasmin  |e VerfasserIn  |4 aut 
700 1 |a Christopher, Mark  |e VerfasserIn  |4 aut 
700 1 |a Hyman, Leslie  |e VerfasserIn  |4 aut 
700 1 |a Jonas, Jost B.  |d 1958-  |e VerfasserIn  |0 (DE-588)1028286732  |0 (DE-627)730536823  |0 (DE-576)37578537X  |4 aut 
700 1 |a Weinreb, Robert N.  |e VerfasserIn  |4 aut 
700 1 |a Zangwill, Linda M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t American journal of ophthalmology  |d New York, NY : Elsevier Science, 1918  |g 242(2022) vom: Okt., Seite 26-35  |h Online-Ressource  |w (DE-627)320596281  |w (DE-600)2019600-3  |w (DE-576)121466353  |x 1879-1891  |7 nnas  |a Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia 
773 1 8 |g volume:242  |g year:2022  |g month:10  |g pages:26-35  |g extent:10  |a Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia 
856 4 0 |u https://doi.org/10.1016/j.ajo.2022.04.019  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0002939422001684  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230801 
993 |a Article 
994 |a 2022 
998 |g 1028286732  |a Jonas, Jost B.  |m 1028286732:Jonas, Jost B.  |d 60000  |e 60000PJ1028286732  |k 0/60000/  |p 6 
999 |a KXP-PPN1854026828  |e 4361731802 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"role":"aut","given":"Christopher","family":"Bowd","display":"Bowd, Christopher"},{"role":"aut","given":"Akram","family":"Belghith","display":"Belghith, Akram"},{"display":"Rezapour, Jasmin","family":"Rezapour","given":"Jasmin","role":"aut"},{"display":"Christopher, Mark","family":"Christopher","given":"Mark","role":"aut"},{"family":"Hyman","display":"Hyman, Leslie","given":"Leslie","role":"aut"},{"given":"Jost B.","role":"aut","family":"Jonas","display":"Jonas, Jost B."},{"family":"Weinreb","display":"Weinreb, Robert N.","role":"aut","given":"Robert N."},{"display":"Zangwill, Linda M.","family":"Zangwill","role":"aut","given":"Linda M."}],"name":{"displayForm":["Christopher Bowd, Akram Belghith, Jasmin Rezapour, Mark Christopher, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill"]},"physDesc":[{"extent":"10 S.","noteIll":"Illustrationen"}],"recId":"1854026828","relHost":[{"language":["eng"],"part":{"extent":"10","text":"242(2022) vom: Okt., Seite 26-35","volume":"242","pages":"26-35","year":"2022"},"titleAlt":[{"title":"AJO"}],"origin":[{"publisherPlace":"New York, NY","dateIssuedKey":"1918","publisher":"Elsevier Science","dateIssuedDisp":"1918-"}],"pubHistory":["Nachgewiesen 3.Ser. 1.1918 -"],"note":["Gesehen am 21.09.2020","Ungezählte Beil.: Supplement"],"title":[{"title":"American journal of ophthalmology","title_sort":"American journal of ophthalmology","subtitle":"AJO"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopiaAmerican journal of ophthalmology","recId":"320596281","name":{"displayForm":["Frank W. Newell, ed.-in-chief [u.a.]"]},"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1879-1891"],"zdb":["2019600-3"],"eki":["320596281"]}}],"id":{"eki":["1854026828"],"doi":["10.1016/j.ajo.2022.04.019"]},"note":["Online verfügbar: 2 May 2022, Artikelversion: 9 July 2022","Gesehen am 01.08.2023"],"origin":[{"dateIssuedDisp":"2 May 2022","dateIssuedKey":"2022"}],"title":[{"title_sort":"Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia","title":"Diagnostic accuracy of macular thickness map and texture en face images for detecting glaucoma in eyes with axial high myopia"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a BOWDCHRISTDIAGNOSTIC2202