Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction

Objectives To compare metal artifacts and evaluation of metal artifact reduction algorithms during probe positioning in computed tomography (CT)-guided microwave ablation (MWA), cryoablation (CRYO), and radiofrequency ablation (RFA).Materials and methods Using CT guidance, individual MWA, CRYO, and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Do, Thuy (VerfasserIn) , Haas, A. (VerfasserIn) , Vollherbst, Dominik (VerfasserIn) , Pan, Feng (VerfasserIn) , Melzig, Claudius (VerfasserIn) , Jesser, Jessica (VerfasserIn) , Pereira, P. L. (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Skornitzke, Stephan (VerfasserIn) , Sommer, Christof-Matthias (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 01 May 2023
In: International journal of hyperthermia and thermal therapies
Year: 2023, Jahrgang: 40, Heft: 1, Pages: 1-9
ISSN:1464-5157
DOI:10.1080/02656736.2023.2205071
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1080/02656736.2023.2205071
Verlag, kostenfrei, Volltext: https://www.tandfonline.com/doi/full/10.1080/02656736.2023.2205071
Volltext
Verfasserangaben:T.D. Do, A. Haas, D.F. Vollherbst, F. Pan, C. Melzig, J. Jesser, P.L. Pereira, H.U. Kauczor, S. Skornitzke and C.M. Sommer

MARC

LEADER 00000caa a2200000 c 4500
001 1854080946
003 DE-627
005 20240307063937.0
007 cr uuu---uuuuu
008 230801s2023 xx |||||o 00| ||eng c
024 7 |a 10.1080/02656736.2023.2205071  |2 doi 
035 |a (DE-627)1854080946 
035 |a (DE-599)KXP1854080946 
035 |a (OCoLC)1425213731 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Do, Thuy  |d 1986-  |e VerfasserIn  |0 (DE-588)1156815800  |0 (DE-627)1019763485  |0 (DE-576)502462205  |4 aut 
245 1 0 |a Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction  |c T.D. Do, A. Haas, D.F. Vollherbst, F. Pan, C. Melzig, J. Jesser, P.L. Pereira, H.U. Kauczor, S. Skornitzke and C.M. Sommer 
264 1 |c 01 May 2023 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.08.2023 
520 |a Objectives To compare metal artifacts and evaluation of metal artifact reduction algorithms during probe positioning in computed tomography (CT)-guided microwave ablation (MWA), cryoablation (CRYO), and radiofrequency ablation (RFA).Materials and methods Using CT guidance, individual MWA, CRYO, and RFA ablation probes were placed into the livers of 15 pigs. CT imaging was then performed to determine the probe’s position within the test subject’s liver. Filtered back projection (B30f) and iterative reconstructions (I30-1) were both used with and without dedicated iterative metal artifact reduction (iMAR) to generate images from the initial data sets. Semi-automatic segmentation-based quantitative evaluation was conducted to estimate artifact percentage within the liver, while qualitative evaluation of metal artifact extent and overall image quality was performed by two observers using a 5-point Likert scale: 1-none, 2-mild, 3-moderate, 4-severe, 5-non-diagnostic.Results Among MWA, RFA, and CRYO, compared with non-iMAR in B30f reconstruction, the largest extent of artifact volume percentages were observed for CRYO (11.5-17.9%), followed by MWA (4.7-6.6%) and lastly in RFA (5.5-6.2%). iMAR significantly reduces metal artifacts for CRYO and MWA quantitatively (p = 0.0020; p = 0.0036, respectively) and qualitatively (p = 0.0001, p = 0.0005), but not for RFA. No significant reduction in metal artifact percentage was seen after applying iterative reconstructions (p > 0.05). Noise, contrast-to-noise-ratio, or overall image quality did not differ between probe types, irrespective of the application of iterative reconstruction and iMAR.Conclusion A dedicated metal artifact algorithm may decrease metal artifacts and improves image quality significantly for MWA and CRYO probes. Their application alongside with dedicated metal artifact algorithm should be considered during CT-guided positioning. 
650 4 |a computed tomography 
650 4 |a cryoablation 
650 4 |a CT-guidance 
650 4 |a image quality 
650 4 |a Metal artifact reduction 
650 4 |a microwave ablation 
650 4 |a radiofrequency ablation 
700 1 |a Haas, A.  |e VerfasserIn  |4 aut 
700 1 |a Vollherbst, Dominik  |d 1989-  |e VerfasserIn  |0 (DE-588)1071379569  |0 (DE-627)825819024  |0 (DE-576)407878866  |4 aut 
700 1 |a Pan, Feng  |d 1984-  |e VerfasserIn  |0 (DE-588)1208321285  |0 (DE-627)169458836X  |4 aut 
700 1 |a Melzig, Claudius  |d 1986-  |e VerfasserIn  |0 (DE-588)1072780445  |0 (DE-627)828231389  |0 (DE-576)434238570  |4 aut 
700 1 |a Jesser, Jessica  |d 1983-  |e VerfasserIn  |0 (DE-588)1084615606  |0 (DE-627)848577663  |0 (DE-576)456376135  |4 aut 
700 1 |a Pereira, P. L.  |e VerfasserIn  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
700 1 |a Sommer, Christof-Matthias  |d 1978-  |e VerfasserIn  |0 (DE-588)133929701  |0 (DE-627)558738699  |0 (DE-576)278278035  |4 aut 
773 0 8 |i Enthalten in  |t International journal of hyperthermia and thermal therapies  |d London : Informa UK Limited, 2017  |g 40(2023), 1, Artikel-ID 2205071, Seite 1-9  |h Online-Ressource  |w (DE-627)899027342  |w (DE-600)2907482-4  |w (DE-576)494128909  |x 1464-5157  |7 nnas  |a Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction 
773 1 8 |g volume:40  |g year:2023  |g number:1  |g elocationid:2205071  |g pages:1-9  |g extent:9  |a Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction 
856 4 0 |u https://doi.org/10.1080/02656736.2023.2205071  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.tandfonline.com/doi/full/10.1080/02656736.2023.2205071  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230801 
993 |a Article 
994 |a 2023 
998 |g 133929701  |a Sommer, Christof-Matthias  |m 133929701:Sommer, Christof-Matthias  |d 50000  |e 50000PS133929701  |k 0/50000/  |p 10  |y j 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 50000  |e 50000PS1110072589  |k 0/50000/  |p 9 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1084615606  |a Jesser, Jessica  |m 1084615606:Jesser, Jessica  |d 910000  |d 911100  |e 910000PJ1084615606  |e 911100PJ1084615606  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 1072780445  |a Melzig, Claudius  |m 1072780445:Melzig, Claudius  |d 910000  |d 911400  |e 910000PM1072780445  |e 911400PM1072780445  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1208321285  |a Pan, Feng  |m 1208321285:Pan, Feng  |p 4 
998 |g 1071379569  |a Vollherbst, Dominik  |m 1071379569:Vollherbst, Dominik  |d 910000  |d 911100  |d 50000  |e 910000PV1071379569  |e 911100PV1071379569  |e 50000PV1071379569  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 3 
998 |g 1156815800  |a Do, Thuy  |m 1156815800:Do, Thuy  |d 910000  |d 911400  |d 50000  |e 910000PD1156815800  |e 911400PD1156815800  |e 50000PD1156815800  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1854080946  |e 4361983259 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["T.D. Do, A. Haas, D.F. Vollherbst, F. Pan, C. Melzig, J. Jesser, P.L. Pereira, H.U. Kauczor, S. Skornitzke and C.M. Sommer"]},"id":{"doi":["10.1080/02656736.2023.2205071"],"eki":["1854080946"]},"recId":"1854080946","physDesc":[{"extent":"9 S."}],"origin":[{"dateIssuedDisp":"01 May 2023","dateIssuedKey":"2023"}],"relHost":[{"title":[{"subtitle":"IJH","title":"International journal of hyperthermia and thermal therapies","title_sort":"International journal of hyperthermia and thermal therapies"}],"note":["Gesehen am 18.12.2018"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"origin":[{"publisher":"Informa UK Limited","publisherPlace":"London","dateIssuedDisp":"[2017]-"}],"disp":"Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reductionInternational journal of hyperthermia and thermal therapies","recId":"899027342","physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"40","year":"2023","extent":"9","text":"40(2023), 1, Artikel-ID 2205071, Seite 1-9","issue":"1","pages":"1-9"},"id":{"eki":["899027342"],"issn":["1464-5157"],"zdb":["2907482-4"]},"pubHistory":["Vol. 33, no. 1 (2017)-"],"titleAlt":[{"title":"International journal of hyperthermia"},{"title":"IJH"}]}],"person":[{"family":"Do","role":"aut","given":"Thuy","display":"Do, Thuy"},{"display":"Haas, A.","role":"aut","given":"A.","family":"Haas"},{"role":"aut","given":"Dominik","family":"Vollherbst","display":"Vollherbst, Dominik"},{"family":"Pan","role":"aut","given":"Feng","display":"Pan, Feng"},{"display":"Melzig, Claudius","family":"Melzig","role":"aut","given":"Claudius"},{"role":"aut","given":"Jessica","family":"Jesser","display":"Jesser, Jessica"},{"display":"Pereira, P. L.","family":"Pereira","role":"aut","given":"P. L."},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"display":"Skornitzke, Stephan","given":"Stephan","role":"aut","family":"Skornitzke"},{"display":"Sommer, Christof-Matthias","role":"aut","given":"Christof-Matthias","family":"Sommer"}],"title":[{"title":"Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction","title_sort":"Semi-automatic artifact quantification in thermal ablation probe and algorithms for the evaluation of metal artifact reduction"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 01.08.2023"]} 
SRT |a DOTHUYHAASSEMIAUTOMA0120