Objectives. To characterize for the first time in vivo a novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and test in vivo a multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodi...

Full description

Saved in:
Bibliographic Details
Main Authors: Amato, Carlo (Author) , Susenburger, Markus (Author) , Lehr, Samuel (Author) , Kuntz, Jan (Author) , Gehrke, Nicole (Author) , Franke, Danielle (Author) , Thüring, Thomas (Author) , Briel, Andreas (Author) , Brönnimann, Christian (Author) , Kachelrieß, Marc (Author) , Sawall, Stefan (Author)
Format: Article (Journal)
Language:English
Published: 2023
In: Physics in medicine and biology
Year: 2023, Volume: 68, Issue: 13, Pages: 1-11
ISSN:1361-6560
DOI:10.1088/1361-6560/acdb42
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/acdb42
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/1361-6560/acdb42
Get full text
Author Notes:Carlo Amato, Markus Susenburger, Samuel Lehr, Jan Kuntz, Nicole Gehrke, Danielle Franke, Thomas Thüring, Andreas Briel, Christian Brönnimann, Marc Kachelrieß and Stefan Sawall

MARC

LEADER 00000caa a2200000 c 4500
001 1854986910
003 DE-627
005 20240307062443.0
007 cr uuu---uuuuu
008 230809s2023 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/acdb42  |2 doi 
035 |a (DE-627)1854986910 
035 |a (DE-599)KXP1854986910 
035 |a (OCoLC)1425213260 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Amato, Carlo  |d 1993-  |e VerfasserIn  |0 (DE-588)121527551X  |0 (DE-627)1726554201  |4 aut 
245 1 0 |a Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent  |c Carlo Amato, Markus Susenburger, Samuel Lehr, Jan Kuntz, Nicole Gehrke, Danielle Franke, Thomas Thüring, Andreas Briel, Christian Brönnimann, Marc Kachelrieß and Stefan Sawall 
264 1 |c 2023 
300 |b Illustrationen 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 19. Juni 2023 
500 |a Gesehen am 09.08.2023 
520 |a Objectives. To characterize for the first time in vivo a novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and test in vivo a multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodine-based contrast agent. Approach. A micro-computed tomography scanner was assembled and equipped with a photon-counting detector. Five mice were administered with the bismuth-based contrast agent and systematically scanned over 5 h to quantify the contrast enhancement in relevant organs of interest. Subsequently, the multi-contrast agent protocol was tested on three mice. Material decomposition was performed on the acquired spectral data to quantify the concentration of bismuth and iodine in multiple structures, e.g. the myocardium and vasculature. Main results. In the vasculature, the bismuth agent provides a peak enhancement of 1100 HU and a half-life of about 260 min. After the injection, it accumulates in the liver, spleen and intestinal wall reaching a CT value of 440 HU about 5 h post injection. Phantom measurements showed that the bismuth provides more contrast enhancement than iodine for a variety of tube voltages. The multi-contrast protocol for cardiac imaging successfully allowed the simultaneous decomposition of the vasculature, the brown adipose tissue and the myocardium. Significance. The new bismuth-based contrast agent was proven to have a long circulation time suitable for preclinical applications and to provide more contrast than iodine agents. The proposed multi-contrast protocol resulted in a new tool for cardiac functional imaging. Furthermore, thanks to the contrast enhancement provided in the intestinal wall, the novel contrast agent may be used to develop further multi contrast agent protocols for abdominal and oncological imaging. 
700 1 |a Susenburger, Markus  |e VerfasserIn  |4 aut 
700 1 |a Lehr, Samuel  |e VerfasserIn  |4 aut 
700 1 |a Kuntz, Jan  |d 1983-  |e VerfasserIn  |0 (DE-588)1032152028  |0 (DE-627)738437433  |0 (DE-576)379853655  |4 aut 
700 1 |a Gehrke, Nicole  |e VerfasserIn  |4 aut 
700 1 |a Franke, Danielle  |e VerfasserIn  |4 aut 
700 1 |a Thüring, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Briel, Andreas  |e VerfasserIn  |4 aut 
700 1 |a Brönnimann, Christian  |e VerfasserIn  |4 aut 
700 1 |a Kachelrieß, Marc  |d 1969-  |e VerfasserIn  |0 (DE-588)120866544  |0 (DE-627)705049280  |0 (DE-576)292422725  |4 aut 
700 1 |a Sawall, Stefan  |d 1985-  |e VerfasserIn  |0 (DE-588)1031331298  |0 (DE-627)736275746  |0 (DE-576)378788841  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 68(2023), 13, Artikel-ID 135001, Seite 1-11  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent 
773 1 8 |g volume:68  |g year:2023  |g number:13  |g elocationid:135001  |g pages:1-11  |g extent:11  |a Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent 
856 4 0 |u https://doi.org/10.1088/1361-6560/acdb42  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/acdb42  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230809 
993 |a Article 
994 |a 2023 
998 |g 1031331298  |a Sawall, Stefan  |m 1031331298:Sawall, Stefan  |d 50000  |e 50000PS1031331298  |k 0/50000/  |p 11  |y j 
998 |g 120866544  |a Kachelrieß, Marc  |m 120866544:Kachelrieß, Marc  |d 50000  |e 50000PK120866544  |k 0/50000/  |p 10 
998 |g 1032152028  |a Kuntz, Jan  |m 1032152028:Kuntz, Jan  |d 50000  |e 50000PK1032152028  |k 0/50000/  |p 4 
999 |a KXP-PPN1854986910  |e 4364118494 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Amato, Carlo","family":"Amato","role":"aut","given":"Carlo"},{"given":"Markus","role":"aut","family":"Susenburger","display":"Susenburger, Markus"},{"display":"Lehr, Samuel","family":"Lehr","given":"Samuel","role":"aut"},{"family":"Kuntz","display":"Kuntz, Jan","role":"aut","given":"Jan"},{"role":"aut","given":"Nicole","family":"Gehrke","display":"Gehrke, Nicole"},{"given":"Danielle","role":"aut","display":"Franke, Danielle","family":"Franke"},{"given":"Thomas","role":"aut","family":"Thüring","display":"Thüring, Thomas"},{"family":"Briel","display":"Briel, Andreas","given":"Andreas","role":"aut"},{"family":"Brönnimann","display":"Brönnimann, Christian","given":"Christian","role":"aut"},{"role":"aut","given":"Marc","family":"Kachelrieß","display":"Kachelrieß, Marc"},{"given":"Stefan","role":"aut","family":"Sawall","display":"Sawall, Stefan"}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"2023"}],"note":["Veröffentlicht: 19. Juni 2023","Gesehen am 09.08.2023"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent","title":"Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent"}],"language":["eng"],"physDesc":[{"noteIll":"Illustrationen","extent":"11 S."}],"name":{"displayForm":["Carlo Amato, Markus Susenburger, Samuel Lehr, Jan Kuntz, Nicole Gehrke, Danielle Franke, Thomas Thüring, Andreas Briel, Christian Brönnimann, Marc Kachelrieß and Stefan Sawall"]},"recId":"1854986910","id":{"doi":["10.1088/1361-6560/acdb42"],"eki":["1854986910"]},"relHost":[{"disp":"Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agentPhysics in medicine and biology","part":{"year":"2023","text":"68(2023), 13, Artikel-ID 135001, Seite 1-11","pages":"1-11","extent":"11","volume":"68","issue":"13"},"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"dateIssuedDisp":"1956-","publisherPlace":"Bristol","dateIssuedKey":"1956","publisher":"IOP Publ."}],"title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"269016163","pubHistory":["1.1956 -"],"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]}}]} 