Impact of stent design on in-stent stenosis in a rabbit iliac artery model

The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 microm). Ten stents of each type w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sommer, Christof-Matthias (VerfasserIn) , Grenacher, Lars (VerfasserIn) , Stampfl, Ulrike (VerfasserIn) , Arnegger, Florian (VerfasserIn) , Rehnitz, C. (VerfasserIn) , Thierjung, Heidi (VerfasserIn) , Stampfl, Sibylle (VerfasserIn) , Berger, I. (VerfasserIn) , Richter, Götz Martin (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Radeleff, Boris (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2010
In: CardioVascular and interventional radiology
Year: 2010, Jahrgang: 33, Heft: 3, Pages: 565-575
ISSN:1432-086X
Online-Zugang: Volltext
Verfasserangaben:C.M. Sommer, L. Grenacher, U. Stampfl, F.U. Arnegger, C. Rehnitz, H. Thierjung, S. Stampfl, I. Berger, G.M. Richter, H.U. Kauczor, B.A. Radeleff

MARC

LEADER 00000caa a2200000 c 4500
001 185613282X
003 DE-627
005 20240311125907.0
007 cr uuu---uuuuu
008 230814s2010 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00270-009-9757-6  |2 doi 
035 |a (DE-627)185613282X 
035 |a (DE-599)KXP185613282X 
035 |a (OCoLC)1425874043 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sommer, Christof-Matthias  |d 1978-  |e VerfasserIn  |0 (DE-588)133929701  |0 (DE-627)558738699  |0 (DE-576)278278035  |4 aut 
245 1 0 |a Impact of stent design on in-stent stenosis in a rabbit iliac artery model  |c C.M. Sommer, L. Grenacher, U. Stampfl, F.U. Arnegger, C. Rehnitz, H. Thierjung, S. Stampfl, I. Berger, G.M. Richter, H.U. Kauczor, B.A. Radeleff 
264 1 |c 2010 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: 22 December 2009 
500 |a Gesehen am 14.08.2023 
520 |a The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 microm). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury, vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 microm. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 microm and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important. 
650 4 |a Angiography 
650 4 |a Animals 
650 4 |a Disease Models, Animal 
650 4 |a Graft Occlusion, Vascular 
650 4 |a Iliac Artery 
650 4 |a Male 
650 4 |a Prosthesis Design 
650 4 |a Rabbits 
650 4 |a Stents 
700 1 |a Grenacher, Lars  |d 1967-  |e VerfasserIn  |0 (DE-588)115424598  |0 (DE-627)691308977  |0 (DE-576)289876761  |4 aut 
700 1 |a Stampfl, Ulrike  |d 1978-  |e VerfasserIn  |0 (DE-588)132557711  |0 (DE-627)523645104  |0 (DE-576)261999664  |4 aut 
700 1 |a Arnegger, Florian  |e VerfasserIn  |0 (DE-588)118858930X  |0 (DE-627)1667533444  |4 aut 
700 1 |a Rehnitz, C.  |e VerfasserIn  |4 aut 
700 1 |a Thierjung, Heidi  |d 1980-  |e VerfasserIn  |0 (DE-588)136944752  |0 (DE-627)588716162  |0 (DE-576)301357609  |4 aut 
700 1 |a Stampfl, Sibylle  |d 1978-  |e VerfasserIn  |0 (DE-588)132567113  |0 (DE-627)523952155  |0 (DE-576)262000288  |4 aut 
700 1 |a Berger, I.  |e VerfasserIn  |4 aut 
700 1 |a Richter, Götz Martin  |e VerfasserIn  |0 (DE-588)1068606568  |0 (DE-627)820513555  |0 (DE-576)427924057  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Radeleff, Boris  |d 1969-  |e VerfasserIn  |0 (DE-588)123910846  |0 (DE-627)706470826  |0 (DE-576)293938504  |4 aut 
773 0 8 |i Enthalten in  |t CardioVascular and interventional radiology  |d Berlin : Springer, 1978  |g 33(2010), 3, Seite 565-575  |h Online-Ressource  |w (DE-627)253390451  |w (DE-600)1458490-6  |w (DE-576)072283483  |x 1432-086X  |7 nnas  |a Impact of stent design on in-stent stenosis in a rabbit iliac artery model 
773 1 8 |g volume:33  |g year:2010  |g number:3  |g pages:565-575  |g extent:11  |a Impact of stent design on in-stent stenosis in a rabbit iliac artery model 
951 |a AR 
992 |a 20230814 
993 |a Article 
994 |a 2010 
998 |g 123910846  |a Radeleff, Boris  |m 123910846:Radeleff, Boris  |d 910000  |d 911400  |e 910000PR123910846  |e 911400PR123910846  |k 0/910000/  |k 1/910000/911400/  |p 11  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 1068606568  |a Richter, Götz Martin  |m 1068606568:Richter, Götz Martin  |d 50000  |e 50000PR1068606568  |k 0/50000/  |p 9 
998 |g 132567113  |a Stampfl, Sibylle  |m 132567113:Stampfl, Sibylle  |d 910000  |d 911100  |e 910000PS132567113  |e 911100PS132567113  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 136944752  |a Thierjung, Heidi  |m 136944752:Thierjung, Heidi  |d 910000  |d 911400  |e 910000PT136944752  |e 911400PT136944752  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 118858930X  |a Arnegger, Florian  |m 118858930X:Arnegger, Florian  |d 910000  |d 910200  |e 910000PA118858930X  |e 910200PA118858930X  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 132557711  |a Stampfl, Ulrike  |m 132557711:Stampfl, Ulrike  |d 910000  |d 911400  |e 910000PS132557711  |e 911400PS132557711  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 115424598  |a Grenacher, Lars  |m 115424598:Grenacher, Lars  |d 910000  |d 911400  |e 910000PG115424598  |e 911400PG115424598  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 133929701  |a Sommer, Christof-Matthias  |m 133929701:Sommer, Christof-Matthias  |d 910000  |d 911400  |e 910000PS133929701  |e 911400PS133929701  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN185613282X  |e 4365963309 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["185613282X"],"doi":["10.1007/s00270-009-9757-6"]},"name":{"displayForm":["C.M. Sommer, L. Grenacher, U. Stampfl, F.U. Arnegger, C. Rehnitz, H. Thierjung, S. Stampfl, I. Berger, G.M. Richter, H.U. Kauczor, B.A. Radeleff"]},"title":[{"title":"Impact of stent design on in-stent stenosis in a rabbit iliac artery model","title_sort":"Impact of stent design on in-stent stenosis in a rabbit iliac artery model"}],"note":["Published online: 22 December 2009","Gesehen am 14.08.2023"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"disp":"Impact of stent design on in-stent stenosis in a rabbit iliac artery modelCardioVascular and interventional radiology","recId":"253390451","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"CardioVascular and interventional radiology","title":"CardioVascular and interventional radiology","subtitle":"CVIR"}],"note":["Gesehen am 27. November 2017","Fortsetzung der Druck-Ausgabe","Ungezählte Beil. ab 20.1997: Supplement"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"1978","publisherPlace":"Berlin ; Heidelberg ; New York, NY","dateIssuedDisp":"1978-","publisher":"Springer ; Springer"}],"part":{"issue":"3","text":"33(2010), 3, Seite 565-575","extent":"11","pages":"565-575","volume":"33","year":"2010"},"id":{"zdb":["1458490-6"],"eki":["253390451"],"issn":["1432-086X"]},"titleAlt":[{"title":"CVIR"},{"title":"Cardiovascular radiology"},{"title":"CardioVascular & interventional radiology"}],"pubHistory":["1.1978 -"]}],"person":[{"role":"aut","given":"Christof-Matthias","family":"Sommer","display":"Sommer, Christof-Matthias"},{"family":"Grenacher","role":"aut","given":"Lars","display":"Grenacher, Lars"},{"role":"aut","given":"Ulrike","family":"Stampfl","display":"Stampfl, Ulrike"},{"family":"Arnegger","given":"Florian","role":"aut","display":"Arnegger, Florian"},{"given":"C.","role":"aut","family":"Rehnitz","display":"Rehnitz, C."},{"family":"Thierjung","given":"Heidi","role":"aut","display":"Thierjung, Heidi"},{"display":"Stampfl, Sibylle","family":"Stampfl","role":"aut","given":"Sibylle"},{"role":"aut","given":"I.","family":"Berger","display":"Berger, I."},{"family":"Richter","given":"Götz Martin","role":"aut","display":"Richter, Götz Martin"},{"family":"Kauczor","role":"aut","given":"Hans-Ulrich","display":"Kauczor, Hans-Ulrich"},{"given":"Boris","role":"aut","family":"Radeleff","display":"Radeleff, Boris"}],"origin":[{"dateIssuedDisp":"2010","dateIssuedKey":"2010"}],"recId":"185613282X","physDesc":[{"extent":"11 S."}]} 
SRT |a SOMMERCHRIIMPACTOFST2010