Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry

Objectives To assess the interreader and test-retest reliability of magnetization transfer imaging (MTI) and T2 relaxometry in sciatic nerve MR neurography (MRN). Materials and methods In this prospective study, 21 healthy volunteers were examined three times on separate days by a standardized MRN p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Preisner, Fabian (VerfasserIn) , Behnisch, Rouven (VerfasserIn) , Fösleitner, Olivia (VerfasserIn) , Schwarz, Daniel (VerfasserIn) , Wehrstein, Michaela (VerfasserIn) , Meredig, Hagen (VerfasserIn) , Friedmann-Bette, Birgit (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Kronlage, Moritz (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 9 June 2021
In: European radiology
Year: 2021, Jahrgang: 31, Heft: 12, Pages: 9120-9130
ISSN:1432-1084
DOI:10.1007/s00330-021-08072-9
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00330-021-08072-9
Verlag, kostenfrei, Volltext: https://link.springer.com/10.1007/s00330-021-08072-9
Volltext
Verfasserangaben:Fabian Preisner, Rouven Behnisch, Olivia Foesleitner, Daniel Schwarz, Michaela Wehrstein, Hagen Meredig, Birgit Friedmann-Bette, Sabine Heiland, Martin Bendszus, Moritz Kronlage

MARC

LEADER 00000caa a2200000 c 4500
001 185621270X
003 DE-627
005 20240306115622.0
007 cr uuu---uuuuu
008 230815s2021 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-021-08072-9  |2 doi 
035 |a (DE-627)185621270X 
035 |a (DE-599)KXP185621270X 
035 |a (OCoLC)1425064211 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Preisner, Fabian  |d 1988-  |e VerfasserIn  |0 (DE-588)1196155534  |0 (DE-627)167801284X  |4 aut 
245 1 0 |a Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry  |c Fabian Preisner, Rouven Behnisch, Olivia Foesleitner, Daniel Schwarz, Michaela Wehrstein, Hagen Meredig, Birgit Friedmann-Bette, Sabine Heiland, Martin Bendszus, Moritz Kronlage 
264 1 |c 9 June 2021 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.8.2023 
520 |a Objectives To assess the interreader and test-retest reliability of magnetization transfer imaging (MTI) and T2 relaxometry in sciatic nerve MR neurography (MRN). Materials and methods In this prospective study, 21 healthy volunteers were examined three times on separate days by a standardized MRN protocol at 3 Tesla, consisting of an MTI sequence, a multi-echo T2 relaxometry sequence, and a highresolution T2-weighted sequence. Magnetization transfer ratio (MTR), T2 relaxation time, and proton spin density (PSD) of the sciatic nerve were assessed by two independent observers, and both interreader and test-retest reliability for all readout parameters were reported by intraclass correlation coefficients (ICCs) and standard error of measurement (SEM). - Results For the sciatic nerve, overall mean ± standard deviation MTR was 26.75 ± 3.5%, T2 was 64.54 ± 8.2 ms, and PSD was 340.93 ± 78.8. ICCs ranged between 0.81 (MTR) and 0.94 (PSD) for interreader reliability and between 0.75 (MTR) and 0.94 (PSD) for test-retest reliability. SEM for interreader reliability was 1.7% for MTR, 2.67 ms for T2, and 21.3 for PSD. SEM for test-retest reliability was 1.7% for MTR, 2.66 ms for T2, and 20.1 for PSD. - Conclusions MTI and T2 relaxometry of the sciatic nerve are reliable and reproducible. The values of measurement imprecision reported here may serve as a guide for correct interpretation of quantitative MRN biomarkers in future studies. Key Points • Magnetization transfer imaging (MTI) and T2 relaxometry of the sciatic nerve are reliable and reproducible. • The imprecision that is unavoidably associated with different scans or different readers can be estimated by the here presented SEM values for the biomarkers T2, PSD, and MTR. • These values may serve as a guide for correct interpretation of quantitative MRN biomarkers in future studies and possible clinical applications. 
700 1 |a Behnisch, Rouven  |d 1990-  |e VerfasserIn  |0 (DE-588)1191206238  |0 (DE-627)1669619265  |4 aut 
700 1 |a Fösleitner, Olivia  |e VerfasserIn  |0 (DE-588)1255100338  |0 (DE-627)1798288249  |4 aut 
700 1 |a Schwarz, Daniel  |d 1983-  |e VerfasserIn  |0 (DE-588)1104866781  |0 (DE-627)862224926  |0 (DE-576)472943065  |4 aut 
700 1 |a Wehrstein, Michaela  |d 1989-  |e VerfasserIn  |0 (DE-588)125295378X  |0 (DE-627)1794808574  |4 aut 
700 1 |a Meredig, Hagen  |d 1984-  |e VerfasserIn  |0 (DE-588)101336919X  |0 (DE-627)664163173  |0 (DE-576)346990475  |4 aut 
700 1 |a Friedmann-Bette, Birgit  |d 1960-  |e VerfasserIn  |0 (DE-588)112694195  |0 (DE-627)519225937  |0 (DE-576)289739683  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Kronlage, Moritz  |d 1984-  |e VerfasserIn  |0 (DE-588)1027093531  |0 (DE-627)728260050  |0 (DE-576)37246887X  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 31(2021), 12, Seite 9120-9130  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry 
773 1 8 |g volume:31  |g year:2021  |g number:12  |g pages:9120-9130  |g extent:11  |a Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry 
856 4 0 |u https://doi.org/10.1007/s00330-021-08072-9  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://link.springer.com/10.1007/s00330-021-08072-9  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230815 
993 |a Article 
994 |a 2021 
998 |g 1027093531  |a Kronlage, Moritz  |m 1027093531:Kronlage, Moritz  |d 910000  |d 911100  |d 50000  |e 910000PK1027093531  |e 911100PK1027093531  |e 50000PK1027093531  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 10  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 9 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 112694195  |a Friedmann-Bette, Birgit  |m 112694195:Friedmann-Bette, Birgit  |d 910000  |d 910100  |d 50000  |e 910000PF112694195  |e 910100PF112694195  |e 50000PF112694195  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 7 
998 |g 101336919X  |a Meredig, Hagen  |m 101336919X:Meredig, Hagen  |d 910000  |d 911100  |e 910000PM101336919X  |e 911100PM101336919X  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 125295378X  |a Wehrstein, Michaela  |m 125295378X:Wehrstein, Michaela  |d 910000  |d 910100  |e 910000PW125295378X  |e 910100PW125295378X  |k 0/910000/  |k 1/910000/910100/  |p 5 
998 |g 1104866781  |a Schwarz, Daniel  |m 1104866781:Schwarz, Daniel  |d 910000  |d 911100  |e 910000PS1104866781  |e 911100PS1104866781  |k 0/910000/  |k 1/910000/911100/  |p 4 
998 |g 1255100338  |a Fösleitner, Olivia  |m 1255100338:Fösleitner, Olivia  |d 910000  |d 911100  |e 910000PF1255100338  |e 911100PF1255100338  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1191206238  |a Behnisch, Rouven  |m 1191206238:Behnisch, Rouven  |d 910000  |d 911800  |e 910000PB1191206238  |e 911800PB1191206238  |k 0/910000/  |k 1/910000/911800/  |p 2 
998 |g 1196155534  |a Preisner, Fabian  |m 1196155534:Preisner, Fabian  |d 910000  |d 911100  |e 910000PP1196155534  |e 911100PP1196155534  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN185621270X  |e 4366349558 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry","title":"Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry"}],"note":["Gesehen am 15.8.2023"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"display":"Preisner, Fabian","given":"Fabian","role":"aut","family":"Preisner"},{"display":"Behnisch, Rouven","family":"Behnisch","role":"aut","given":"Rouven"},{"family":"Fösleitner","given":"Olivia","role":"aut","display":"Fösleitner, Olivia"},{"family":"Schwarz","given":"Daniel","role":"aut","display":"Schwarz, Daniel"},{"display":"Wehrstein, Michaela","role":"aut","given":"Michaela","family":"Wehrstein"},{"family":"Meredig","given":"Hagen","role":"aut","display":"Meredig, Hagen"},{"display":"Friedmann-Bette, Birgit","family":"Friedmann-Bette","role":"aut","given":"Birgit"},{"family":"Heiland","given":"Sabine","role":"aut","display":"Heiland, Sabine"},{"display":"Bendszus, Martin","family":"Bendszus","role":"aut","given":"Martin"},{"display":"Kronlage, Moritz","family":"Kronlage","role":"aut","given":"Moritz"}],"relHost":[{"part":{"issue":"12","text":"31(2021), 12, Seite 9120-9130","extent":"11","pages":"9120-9130","volume":"31","year":"2021"},"id":{"eki":["268757526"],"issn":["1432-1084","1613-3757"],"zdb":["1472718-3"]},"pubHistory":["1.1991 -"],"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"corporate":[{"display":"European Association of Radiology","role":"isb"}],"disp":"Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometryEuropean radiology","recId":"268757526","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"European radiology","title_sort":"European radiology","subtitle":"official organ of the European Association of Radiology"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"publisher":"Springer","dateIssuedKey":"1991","publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1991-"}]}],"origin":[{"dateIssuedDisp":"9 June 2021","dateIssuedKey":"2021"}],"recId":"185621270X","physDesc":[{"extent":"11 S."}],"id":{"eki":["185621270X"],"doi":["10.1007/s00330-021-08072-9"]},"name":{"displayForm":["Fabian Preisner, Rouven Behnisch, Olivia Foesleitner, Daniel Schwarz, Michaela Wehrstein, Hagen Meredig, Birgit Friedmann-Bette, Sabine Heiland, Martin Bendszus, Moritz Kronlage"]}} 
SRT |a PREISNERFARELIABILIT9202