Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients

Purpose: We aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients.Patients and methods: This is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lunz, André (VerfasserIn) , Falkenhayn, Moritz von (VerfasserIn) , Jäger, Sebastian (VerfasserIn) , Reiner, Tobias (VerfasserIn) , Merle, Christian (VerfasserIn) , Streit, Marcus R. (VerfasserIn) , Renkawitz, Tobias (VerfasserIn) , Innmann, Moritz Maximilian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2023
In: Acta orthopaedica
Year: 2023, Jahrgang: 94, Pages: 321-327
ISSN:1745-3682
DOI:10.2340/17453674.2023.13385
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.2340/17453674.2023.13385
Verlag, kostenfrei, Volltext: https://actaorthop.org/actao/article/view/13385
Volltext
Verfasserangaben:Andre Lunz, Moritz von Falkenhayn, Sebastian Jaeger, Tobias Reiner, Christian Merle, Marcus R. Streit, Tobias Renkawitz, and Moritz M. Innmann

MARC

LEADER 00000caa a2200000 c 4500
001 1857881370
003 DE-627
005 20251127151058.0
007 cr uuu---uuuuu
008 230824s2023 xx |||||o 00| ||eng c
024 7 |a 10.2340/17453674.2023.13385  |2 doi 
035 |a (DE-627)1857881370 
035 |a (DE-599)KXP1857881370 
035 |a (OCoLC)1425212642 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Lunz, André  |e VerfasserIn  |0 (DE-588)1220257877  |0 (DE-627)1736627732  |4 aut 
245 1 0 |a Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients  |c Andre Lunz, Moritz von Falkenhayn, Sebastian Jaeger, Tobias Reiner, Christian Merle, Marcus R. Streit, Tobias Renkawitz, and Moritz M. Innmann 
264 1 |c 2023 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 04.07.2023 
500 |a Gesehen am 24.08.2023 
520 |a Purpose: We aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients.Patients and methods: This is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive total hip replacements (THRs) using a cementless, press-fit cup (Allofit, Zimmer, Warsaw, IN, USA) performed between 1999 and 2001. 28-mm metal-on-metal (MoM) and ceramic-on-conventionally not highly crosslinked polyethylene (CoP) bearings were used in 71% and 28%, respectively. Median patient age at surgery was 52 (range 21-60) years. Kaplan-Meier survival analysis was conducted for different endpoints.Results: The 22-year survival rate for the endpoint aseptic cup or inlay revision was 94% (95% confidence interval [CI] 87-96) and 99% (CI 94-100) for aseptic cup loosening. 20 patients (21 THRs; 17%) had died and 5 (5 THRs; 4%) were lost to follow-up. No THR showed evidence of radiographic cup loosening. Osteolysis was observed in 40% of THRs with MoM and 77% with CoP bearings. 88% of THRs with CoP bearings showed significant polyethylene wear.Conclusion: The investigated cementless press-fit cup, which is still in clinical use today, showed excellent long-term survival rates in patients under the age of 60 years at surgery. However, osteolysis due to polyethylene and metal wear was frequently observed and is a matter of concern in the third decade after surgery. 
650 4 |a Allofit 
650 4 |a arthroplasty 
650 4 |a cementless fixation 
650 4 |a implant survival rates 
650 4 |a long-term outcome 
650 4 |a press-fit cup 
650 4 |a total hip replacement 
650 4 |a young patient cohort 
700 1 |a Falkenhayn, Moritz von  |d 1998-  |e VerfasserIn  |0 (DE-588)1374453064  |0 (DE-627)1933761490  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Reiner, Tobias  |d 1982-  |e VerfasserIn  |0 (DE-588)1038723787  |0 (DE-627)766370356  |0 (DE-576)392759853  |4 aut 
700 1 |a Merle, Christian  |d 1979-  |e VerfasserIn  |0 (DE-588)139524541  |0 (DE-627)61181465X  |0 (DE-576)312148577  |4 aut 
700 1 |a Streit, Marcus R.  |d 1982-  |e VerfasserIn  |0 (DE-588)1044249943  |0 (DE-627)77170867X  |0 (DE-576)396814131  |4 aut 
700 1 |a Renkawitz, Tobias  |d 1976-  |e VerfasserIn  |0 (DE-588)129303615  |0 (DE-627)392614979  |0 (DE-576)297588028  |4 aut 
700 1 |a Innmann, Moritz Maximilian  |d 1985-  |e VerfasserIn  |0 (DE-588)1066499470  |0 (DE-627)817645535  |0 (DE-576)426014391  |4 aut 
773 0 8 |i Enthalten in  |t Acta orthopaedica  |d London [u.a.] : Taylor & Francis Group, 2005  |g 94(2023), Seite 321-327  |h Online-Ressource  |w (DE-627)486185206  |w (DE-600)2187223-5  |w (DE-576)11764952X  |x 1745-3682  |7 nnas  |a Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients 
773 1 8 |g volume:94  |g year:2023  |g pages:321-327  |g extent:7  |a Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients 
856 4 0 |u https://doi.org/10.2340/17453674.2023.13385  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://actaorthop.org/actao/article/view/13385  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230824 
993 |a Article 
994 |a 2023 
998 |g 1066499470  |a Innmann, Moritz Maximilian  |m 1066499470:Innmann, Moritz Maximilian  |d 910000  |d 911460  |d 50000  |e 910000PI1066499470  |e 911460PI1066499470  |e 50000PI1066499470  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 8  |y j 
998 |g 129303615  |a Renkawitz, Tobias  |m 129303615:Renkawitz, Tobias  |d 910000  |d 911460  |e 910000PR129303615  |e 911460PR129303615  |k 0/910000/  |k 1/910000/911460/  |p 7 
998 |g 1044249943  |a Streit, Marcus R.  |m 1044249943:Streit, Marcus R.  |d 50000  |e 50000PS1044249943  |k 0/50000/  |p 6 
998 |g 139524541  |a Merle, Christian  |m 139524541:Merle, Christian  |d 910000  |d 911460  |e 910000PM139524541  |e 911460PM139524541  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1038723787  |a Reiner, Tobias  |m 1038723787:Reiner, Tobias  |d 910000  |d 911460  |d 50000  |e 910000PR1038723787  |e 911460PR1038723787  |e 50000PR1038723787  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 4 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 1374453064  |a Falkenhay, Moritz von  |m 1374453064:Falkenhay, Moritz von  |d 50000  |e 50000PF1374453064  |k 0/50000/  |p 2 
998 |g 1220257877  |a Lunz, André  |m 1220257877:Lunz, André  |d 910000  |d 911460  |e 910000PL1220257877  |e 911460PL1220257877  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1857881370  |e 4370034671 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients","title_sort":"Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients"}],"language":["eng"],"name":{"displayForm":["Andre Lunz, Moritz von Falkenhayn, Sebastian Jaeger, Tobias Reiner, Christian Merle, Marcus R. Streit, Tobias Renkawitz, and Moritz M. Innmann"]},"origin":[{"dateIssuedDisp":"2023","dateIssuedKey":"2023"}],"recId":"1857881370","person":[{"family":"Lunz","display":"Lunz, André","given":"André","role":"aut"},{"family":"Falkenhayn","display":"Falkenhayn, Moritz von","given":"Moritz von","role":"aut"},{"role":"aut","display":"Jäger, Sebastian","given":"Sebastian","family":"Jäger"},{"role":"aut","given":"Tobias","display":"Reiner, Tobias","family":"Reiner"},{"role":"aut","display":"Merle, Christian","given":"Christian","family":"Merle"},{"display":"Streit, Marcus R.","given":"Marcus R.","family":"Streit","role":"aut"},{"role":"aut","display":"Renkawitz, Tobias","given":"Tobias","family":"Renkawitz"},{"role":"aut","family":"Innmann","display":"Innmann, Moritz Maximilian","given":"Moritz Maximilian"}],"note":["Veröffentlicht: 04.07.2023","Gesehen am 24.08.2023"],"relHost":[{"note":["Gesehen am 09.09.15"],"part":{"pages":"321-327","extent":"7","year":"2023","volume":"94","text":"94(2023), Seite 321-327"},"id":{"eki":["486185206"],"zdb":["2187223-5"],"issn":["1745-3682"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Acta orthopaedica","title_sort":"Acta orthopaedica"}],"origin":[{"dateIssuedKey":"2005","publisherPlace":"London [u.a.] ; London","publisher":"Taylor & Francis Group ; Informa Healthcare","dateIssuedDisp":"2005-"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["76.2005 -"],"language":["eng"],"disp":"Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patientsActa orthopaedica","recId":"486185206"}],"id":{"doi":["10.2340/17453674.2023.13385"],"eki":["1857881370"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}]} 
SRT |a LUNZANDREFMINIMUM20Y2023