Intraocular lens power calculation after laser refractive surgery: corrective algorithm for corneal power estimation

PURPOSE: - To evaluate an algorithm for corneal power estimation in intraocular lens (IOL) power calculation after myopic laser refractive surgery using direct corneal measurements. - SETTING: - International Vision Correction Research Centre, University of Heidelberg, Heidelberg, German...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jin, Haiying (VerfasserIn) , Holzer, Mike P. (VerfasserIn) , Rabsilber, Tanja Marina (VerfasserIn) , Borkenstein, Andreas (VerfasserIn) , Limberger, Il-Joo (VerfasserIn) , Guo, Haike (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [January 2010]
In: Journal of cataract and refractive surgery
Year: 2010, Jahrgang: 36, Heft: 1, Pages: 87-96
ISSN:1873-4502
DOI:10.1016/j.jcrs.2009.07.011
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2009.07.011
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/abstract/2010/01000/intraocular_lens_power_calculation_after_laser.15.aspx
Volltext
Verfasserangaben:Haiying Jin, Mike P. Holzer, Tanja Rabsilber, Andreas F. Borkenstein, Il-Joo Limberger, Haike Guo, Gerd U. Auffarth

MARC

LEADER 00000caa a22000002c 4500
001 1857909771
003 DE-627
005 20240329080540.0
007 cr uuu---uuuuu
008 230824s2010 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcrs.2009.07.011  |2 doi 
035 |a (DE-627)1857909771 
035 |a (DE-599)KXP1857909771 
035 |a (OCoLC)1425874258 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jin, Haiying  |d 1976-  |e VerfasserIn  |0 (DE-588)137505213  |0 (DE-627)695837915  |0 (DE-576)303400196  |4 aut 
245 1 0 |a Intraocular lens power calculation after laser refractive surgery  |b corrective algorithm for corneal power estimation  |c Haiying Jin, Mike P. Holzer, Tanja Rabsilber, Andreas F. Borkenstein, Il-Joo Limberger, Haike Guo, Gerd U. Auffarth 
264 1 |c [January 2010] 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.08.2023 
520 |a PURPOSE: - To evaluate an algorithm for corneal power estimation in intraocular lens (IOL) power calculation after myopic laser refractive surgery using direct corneal measurements. - SETTING: - International Vision Correction Research Centre, University of Heidelberg, Heidelberg, Germany. - METHODS: - Corneal parameters in normal eyes and eyes of refractive surgery cases were evaluated by rotating Scheimpflug imaging. Corneal optical power (Koptical) calculated by a Gaussian optics formula was simplified as Koptical = Kanterior + K2 (Kanterior = anterior corneal power; Kposterior = posterior corneal power; K2 = Kposterior − Kanterior × Kposterior × corneal thickness/1.376). The variation and change in K2 induced by refractive surgery were analyzed. A corrective algorithm to calculate Koptical using mean K2 (−6.10 diopters [D]), Kcorrective = 1.114 × measured K − 6.10, was derived based on statistical analysis, which was in accordance with the modified Maloney method. The IOL power after refractive surgery was calculated using Kcorrective. - RESULTS: - The mean K2 of normal and post-refractive corneas was −6.10 ± 0.23 D and −6.16 ± 0.17 D, respectively (P = .17). The mean refractive surgery-induced change in K2 was −0.06 ± 0.10 D. The variations in K2 were small (95% confident interval, −6.55 to −5.65 [normal cornea]; −6.48 to −5.70 [pre-refractive]; − 6.49 to −5.83 [post-refractive)]. Using Kcorrective for IOL power calculation in post-refractive cases yielded mean absolute prediction errors of 0.58 ± 0.52 D (Haigis), 0.59 ± 0.49 D (double-K Hoffer Q), and 0.58 ± 0.47 D (double-K SRK/T). - CONCLUSION: - The algorithm that induced low error in corneal power estimation was relatively reliable in IOL calculation after myopic laser refractive surgery. - Financial Disclosure: - No author has a financial or proprietary interest in any material or method mentioned. 
700 1 |a Holzer, Mike P.  |d 1973-  |e VerfasserIn  |0 (DE-588)122217527  |0 (DE-627)705818640  |0 (DE-576)293157812  |4 aut 
700 1 |a Rabsilber, Tanja Marina  |d 1977-  |e VerfasserIn  |0 (DE-588)128743271  |0 (DE-627)378689541  |0 (DE-576)297309609  |4 aut 
700 1 |a Borkenstein, Andreas  |e VerfasserIn  |0 (DE-588)1264154968  |0 (DE-627)1812818998  |4 aut 
700 1 |a Limberger, Il-Joo  |d 1953-  |e VerfasserIn  |0 (DE-588)138057958  |0 (DE-627)69630743X  |0 (DE-576)306315947  |4 aut 
700 1 |a Guo, Haike  |e VerfasserIn  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 36(2010), 1 vom: Jan., Seite 87-96  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Intraocular lens power calculation after laser refractive surgery corrective algorithm for corneal power estimation 
773 1 8 |g volume:36  |g year:2010  |g number:1  |g month:01  |g pages:87-96  |g extent:10  |a Intraocular lens power calculation after laser refractive surgery corrective algorithm for corneal power estimation 
856 4 0 |u https://doi.org/10.1016/j.jcrs.2009.07.011  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jcrs/abstract/2010/01000/intraocular_lens_power_calculation_after_laser.15.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230824 
993 |a Article 
994 |a 2010 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 7  |y j 
998 |g 138057958  |a Limberger, Il-Joo  |m 138057958:Limberger, Il-Joo  |d 910000  |d 910900  |e 910000PL138057958  |e 910900PL138057958  |k 0/910000/  |k 1/910000/910900/  |p 5 
998 |g 1264154968  |a Borkenstein, Andreas  |m 1264154968:Borkenstein, Andreas  |d 910000  |d 910900  |e 910000PB1264154968  |e 910900PB1264154968  |k 0/910000/  |k 1/910000/910900/  |p 4 
998 |g 128743271  |a Rabsilber, Tanja Marina  |m 128743271:Rabsilber, Tanja Marina  |d 910000  |d 910900  |e 910000PR128743271  |e 910900PR128743271  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 122217527  |a Holzer, Mike P.  |m 122217527:Holzer, Mike P.  |d 910000  |d 910900  |e 910000PH122217527  |e 910900PH122217527  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 137505213  |a Jin, Haiying  |m 137505213:Jin, Haiying  |d 910000  |d 910900  |e 910000PJ137505213  |e 910900PJ137505213  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1857909771  |e 4370093325 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 24.08.2023"],"language":["eng"],"relHost":[{"pubHistory":["12.1986 -"],"language":["eng"],"disp":"Intraocular lens power calculation after laser refractive surgery corrective algorithm for corneal power estimationJournal of cataract and refractive surgery","title":[{"title":"Journal of cataract and refractive surgery","title_sort":"Journal of cataract and refractive surgery"}],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"zdb":["2019330-0"],"issn":["1873-4502"],"eki":["320594203"]},"part":{"pages":"87-96","text":"36(2010), 1 vom: Jan., Seite 87-96","year":"2010","volume":"36","extent":"10","issue":"1"},"origin":[{"publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","dateIssuedKey":"2020","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedDisp":"2020-"}],"note":["Gesehen am 02.08.24"],"recId":"320594203","physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}]}],"recId":"1857909771","physDesc":[{"extent":"10 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["Haiying Jin, Mike P. Holzer, Tanja Rabsilber, Andreas F. Borkenstein, Il-Joo Limberger, Haike Guo, Gerd U. Auffarth"]},"title":[{"title_sort":"Intraocular lens power calculation after laser refractive surgery","title":"Intraocular lens power calculation after laser refractive surgery","subtitle":"corrective algorithm for corneal power estimation"}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"[January 2010]"}],"person":[{"family":"Jin","display":"Jin, Haiying","role":"aut","given":"Haiying"},{"family":"Holzer","role":"aut","display":"Holzer, Mike P.","given":"Mike P."},{"given":"Tanja Marina","display":"Rabsilber, Tanja Marina","role":"aut","family":"Rabsilber"},{"given":"Andreas","display":"Borkenstein, Andreas","role":"aut","family":"Borkenstein"},{"given":"Il-Joo","display":"Limberger, Il-Joo","role":"aut","family":"Limberger"},{"role":"aut","display":"Guo, Haike","family":"Guo","given":"Haike"},{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."}],"id":{"eki":["1857909771"],"doi":["10.1016/j.jcrs.2009.07.011"]}} 
SRT |a JINHAIYINGINTRAOCULA2010