Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible: the results of a two centre randomised clinical study with an eight-year follow-up

Background - This study was conducted to compare the long-term clinical outcome of patients with jaw disproportion who had had fixation with resorbable polylactic acid containing positioning screws with those who had had titanium positioning screws in bilateral sagittal split ramus osteotomy of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stockmann, Philipp Hubertus Andreas (VerfasserIn) , Böhm, Hartmut (VerfasserIn) , Driemel, Oliver (VerfasserIn) , Mühling, Joachim (VerfasserIn) , Pistner, Hans (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 March 2010
In: Journal of cranio-maxillofacial surgery
Year: 2010, Jahrgang: 38, Heft: 7, Pages: 522-528
ISSN:1878-4119
DOI:10.1016/j.jcms.2010.01.002
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcms.2010.01.002
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S101051821000003X
Volltext
Verfasserangaben:Philipp Stockmann, MD, DMD, Hartmut Böhm, MD, DMD, Oliver Driemel, MD, DMD,PhD, Joachim Mühling, MD, DMD, PhD, Head, Hans Pistner, MD, DMD, PhD, Head

MARC

LEADER 00000caa a2200000 c 4500
001 1857984897
003 DE-627
005 20240311125457.0
007 cr uuu---uuuuu
008 230825s2010 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcms.2010.01.002  |2 doi 
035 |a (DE-627)1857984897 
035 |a (DE-599)KXP1857984897 
035 |a (OCoLC)1425874215 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stockmann, Philipp Hubertus Andreas  |d 1973-  |e VerfasserIn  |0 (DE-588)132515253  |0 (DE-627)52332880X  |0 (DE-576)299195384  |4 aut 
245 1 0 |a Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible  |b the results of a two centre randomised clinical study with an eight-year follow-up  |c Philipp Stockmann, MD, DMD, Hartmut Böhm, MD, DMD, Oliver Driemel, MD, DMD,PhD, Joachim Mühling, MD, DMD, PhD, Head, Hans Pistner, MD, DMD, PhD, Head 
264 1 |c 24 March 2010 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.08.2023 
520 |a Background - This study was conducted to compare the long-term clinical outcome of patients with jaw disproportion who had had fixation with resorbable polylactic acid containing positioning screws with those who had had titanium positioning screws in bilateral sagittal split ramus osteotomy of the mandible (BSSO). - Patients and methods - Sixty-six patients with isolated mandibular jaw disproportion were included and divided randomly into two treatment groups (resorbable and titanium). Patients were followed for 8 years postoperatively using a standardised protocol. Material-specific complications, functional problems and clinical findings within the former operation field were documented. Treatment stability was determined by occlusion criteria. - Results - Thirty-four patients (54%) were followed until the end of the study. No significant differences were observed in the outcomes of patients in the two groups related to the materials used for osteosynthesis or the long-term treatment stability. During the study, no foreign body reactions were observed. - Conclusion - This study showed that resorbable and titanium positioning screws were equally effective as fixation devices in sagittal split osteotomy. Complete resorption of the resorbable screws could not be verified because of the absence of histological examination, however, the use of resorbable positioning screws can be considered as an alternative osteosynthesis material to conventional titanium osteosynthesis devices in sagittal split osteotomy. 
650 4 |a controlled clinical trial 
650 4 |a orthognathic surgery 
650 4 |a polylactide 
650 4 |a resorbable osteosynthesis 
700 1 |a Böhm, Hartmut  |e VerfasserIn  |4 aut 
700 1 |a Driemel, Oliver  |e VerfasserIn  |4 aut 
700 1 |a Mühling, Joachim  |d 1948-2009  |e VerfasserIn  |0 (DE-588)172266041  |0 (DE-627)697176452  |0 (DE-576)133134032  |4 aut 
700 1 |a Pistner, Hans  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cranio-maxillofacial surgery  |d Oxford [u.a.] : Elsevier, 1987  |g 38(2010), 7 vom: Okt., Seite 522-528  |h Online-Ressource  |w (DE-627)320479218  |w (DE-600)2009565-X  |w (DE-576)10374696X  |x 1878-4119  |7 nnas  |a Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible the results of a two centre randomised clinical study with an eight-year follow-up 
773 1 8 |g volume:38  |g year:2010  |g number:7  |g month:10  |g pages:522-528  |g extent:7  |a Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible the results of a two centre randomised clinical study with an eight-year follow-up 
856 4 0 |u https://doi.org/10.1016/j.jcms.2010.01.002  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S101051821000003X  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230825 
993 |a Article 
994 |a 2010 
998 |g 172266041  |a Mühling, Joachim  |m 172266041:Mühling, Joachim  |d 910000  |d 910800  |e 910000PM172266041  |e 910800PM172266041  |k 0/910000/  |k 1/910000/910800/  |p 4 
999 |a KXP-PPN1857984897  |e 4370356180 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible","title":"Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible","subtitle":"the results of a two centre randomised clinical study with an eight-year follow-up"}],"person":[{"family":"Stockmann","given":"Philipp Hubertus Andreas","roleDisplay":"VerfasserIn","display":"Stockmann, Philipp Hubertus Andreas","role":"aut"},{"family":"Böhm","given":"Hartmut","display":"Böhm, Hartmut","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Driemel, Oliver","role":"aut","family":"Driemel","given":"Oliver"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Mühling, Joachim","given":"Joachim","family":"Mühling"},{"family":"Pistner","given":"Hans","display":"Pistner, Hans","roleDisplay":"VerfasserIn","role":"aut"}],"language":["eng"],"recId":"1857984897","note":["Gesehen am 25.08.2023"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1857984897"],"doi":["10.1016/j.jcms.2010.01.002"]},"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"24 March 2010"}],"name":{"displayForm":["Philipp Stockmann, MD, DMD, Hartmut Böhm, MD, DMD, Oliver Driemel, MD, DMD,PhD, Joachim Mühling, MD, DMD, PhD, Head, Hans Pistner, MD, DMD, PhD, Head"]},"relHost":[{"id":{"issn":["1878-4119"],"zdb":["2009565-X"],"eki":["320479218"]},"origin":[{"dateIssuedKey":"1987","publisher":"Elsevier ; Churchill Livingstone","dateIssuedDisp":"1987-","publisherPlace":"Oxford [u.a.] ; Edinburgh [u.a.]"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of cranio-maxillofacial surgery","subtitle":"official publication of the European Association for Cranio-Maxillofacial Surgery","title_sort":"Journal of cranio-maxillofacial surgery"}],"language":["eng"],"recId":"320479218","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 11.06.18"],"disp":"Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible the results of a two centre randomised clinical study with an eight-year follow-upJournal of cranio-maxillofacial surgery","part":{"volume":"38","text":"38(2010), 7 vom: Okt., Seite 522-528","extent":"7","year":"2010","pages":"522-528","issue":"7"},"pubHistory":["Nachgewiesen 15.1987 -"]}],"physDesc":[{"extent":"7 S."}]} 
SRT |a STOCKMANNPRESORBABLE2420