Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy
Purpose - The objectives of this study were to assess the utility of dynamic contrast-enhanced magnetic resonance (MR) imaging in quantifying parenchymal perfusional changes after embolization and to characterize the association between pharmacokinetic (PK) parameters and final microwave ablation vo...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
February 2023
|
| In: |
Journal of vascular and interventional radiology
Year: 2023, Jahrgang: 34, Heft: 2, Pages: 253-260 |
| ISSN: | 1535-7732 |
| DOI: | 10.1016/j.jvir.2022.10.041 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jvir.2022.10.041 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1051044322013203 |
| Verfasserangaben: | Jason Chiang, Hiro Sparks, Johann S. Rink, M. Franca Meloni, Frank Hao, Kyung H. Sung, and Edward W. Lee |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1858022134 | ||
| 003 | DE-627 | ||
| 005 | 20240329080547.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230828s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jvir.2022.10.041 |2 doi | |
| 035 | |a (DE-627)1858022134 | ||
| 035 | |a (DE-599)KXP1858022134 | ||
| 035 | |a (OCoLC)1425212560 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Chiang, Jason |e VerfasserIn |0 (DE-588)1300269294 |0 (DE-627)1858022797 |4 aut | |
| 245 | 1 | 0 | |a Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy |c Jason Chiang, Hiro Sparks, Johann S. Rink, M. Franca Meloni, Frank Hao, Kyung H. Sung, and Edward W. Lee |
| 264 | 1 | |c February 2023 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online verfügbar: 8. November 2022, Artikelversion: 24. Januar 2023 | ||
| 500 | |a Gesehen am 28.08.2023 | ||
| 520 | |a Purpose - The objectives of this study were to assess the utility of dynamic contrast-enhanced magnetic resonance (MR) imaging in quantifying parenchymal perfusional changes after embolization and to characterize the association between pharmacokinetic (PK) parameters and final microwave ablation volume. - Materials and Methods - PK parameters from dynamic contrast-enhanced MR imaging were used to quantify perfusional changes in the liver after transarterial embolization of the right or left lobe in a swine liver model (n = 5). Each animal subject subsequently underwent microwave ablation (60 W for 5 minutes) of the embolized and nonembolized liver lobes. Changes in PK parameters from dynamic contrast-enhanced MR imaging were correlated with their respective final microwave ablation volumes in each liver lobe. - Results - Microwave ablation volumes of embolized liver lobes were significantly larger than those of nonembolized liver lobes (28.0 mL ± 6.2 vs 15.1 mL ± 5.2, P < .001). PK perfusion parameters were significantly lower in embolized liver lobes than in nonembolized liver lobes (Ktrans = 0.69 min−1 ± 0.15 vs 1.52 min−1 ± 0.37, P < .001; kep = 0.69 min−1 ± 0.19 vs 1.54 min−1 ± 0.42, P < .001). There was a moderate but significant correlation between normalized kep and ablation volume, with each unit increase in normalized kep corresponding to a 9.8-mL decrease in ablation volume (P = .035). - Conclusions - PK-derived parameters from dynamic contrast-enhanced MR imaging can be used to quantify perfusional changes after transarterial embolization and are directly inversely correlated with final ablation volume. | ||
| 700 | 1 | |a Sparks, Hiro |e VerfasserIn |4 aut | |
| 700 | 1 | |a Rink, Johann |d 1988- |e VerfasserIn |0 (DE-588)1160454043 |0 (DE-627)1023629909 |0 (DE-576)505901277 |4 aut | |
| 700 | 1 | |a Meloni, M. Franca |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hao, Frank |e VerfasserIn |4 aut | |
| 700 | 1 | |a Sung, Kyung H. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Lee, Edward W. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of vascular and interventional radiology |d Amsterdam [u.a.] : Elsevier, 1990 |g 34(2023), 2 vom: Feb., Seite 253-260 |h Online-Ressource |w (DE-627)326643524 |w (DE-600)2041331-2 |w (DE-576)094480702 |x 1535-7732 |7 nnas |a Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy |
| 773 | 1 | 8 | |g volume:34 |g year:2023 |g number:2 |g month:02 |g pages:253-260 |g extent:8 |a Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jvir.2022.10.041 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S1051044322013203 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230828 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 1160454043 |a Rink, Johann |m 1160454043:Rink, Johann |d 60000 |d 62900 |e 60000PR1160454043 |e 62900PR1160454043 |k 0/60000/ |k 1/60000/62900/ |p 3 | ||
| 999 | |a KXP-PPN1858022134 |e 437048040X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1858022134"],"doi":["10.1016/j.jvir.2022.10.041"]},"physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Jason Chiang, Hiro Sparks, Johann S. Rink, M. Franca Meloni, Frank Hao, Kyung H. Sung, and Edward W. Lee"]},"recId":"1858022134","relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"326643524","id":{"zdb":["2041331-2"],"issn":["1535-7732"],"eki":["326643524"]},"origin":[{"publisherPlace":"Amsterdam [u.a.] ; Hagerstown, Md.","dateIssuedKey":"1990","publisher":"Elsevier ; Lippincott Williams & Wilkins","dateIssuedDisp":"1990-"}],"pubHistory":["1.1990 -"],"note":["Gesehen am 06.09.13"],"title":[{"title":"Journal of vascular and interventional radiology","title_sort":"Journal of vascular and interventional radiology","subtitle":"JVIR ; official journal of the Society of Cardiovascular and Interventional Radiology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapyJournal of vascular and interventional radiology","language":["eng"],"titleAlt":[{"title":"JVIR"}],"part":{"volume":"34","extent":"8","text":"34(2023), 2 vom: Feb., Seite 253-260","issue":"2","pages":"253-260","year":"2023"}}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy","title":"Dynamic contrast-enhanced MR imaging evaluation of perfusional changes and ablation zone size after combination embolization and ablation therapy"}],"note":["Online verfügbar: 8. November 2022, Artikelversion: 24. Januar 2023","Gesehen am 28.08.2023"],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"February 2023"}],"language":["eng"],"person":[{"given":"Jason","role":"aut","display":"Chiang, Jason","family":"Chiang"},{"role":"aut","given":"Hiro","display":"Sparks, Hiro","family":"Sparks"},{"given":"Johann","role":"aut","family":"Rink","display":"Rink, Johann"},{"family":"Meloni","display":"Meloni, M. Franca","role":"aut","given":"M. Franca"},{"display":"Hao, Frank","family":"Hao","role":"aut","given":"Frank"},{"role":"aut","given":"Kyung H.","family":"Sung","display":"Sung, Kyung H."},{"family":"Lee","display":"Lee, Edward W.","given":"Edward W.","role":"aut"}]} | ||
| SRT | |a CHIANGJASODYNAMICCON2023 | ||