First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke

Dynamic oxygen-17 (17O) magnetic resonance imaging (MRI) is an imaging method that enables a direct and non-invasive assessment of cerebral oxygen metabolism and thus potentially the distinction between viable and non-viable tissue employing a three-phase inhalation experiment. The purpose of this i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ebersberger, Louise (VerfasserIn) , Kratzer, Fabian (VerfasserIn) , Potreck, Arne (VerfasserIn) , Niesporek, Sebastian (VerfasserIn) , Keymling, Myriam (VerfasserIn) , Nagel, Armin Michael (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Wick, Wolfgang (VerfasserIn) , Ladd, Mark E. (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Hoffmann, Angelika (VerfasserIn) , Platt, Tanja (VerfasserIn) , Paech, Daniel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 15 June 2023
In: Frontiers in neuroscience
Year: 2023, Jahrgang: 17, Pages: 1-7
ISSN:1662-453X
DOI:10.3389/fnins.2023.1186558
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3389/fnins.2023.1186558
Verlag, lizenzpflichtig, Volltext: https://www.frontiersin.org/articles/10.3389/fnins.2023.1186558
Volltext
Verfasserangaben:Louise Ebersberger, Fabian J. Kratzer, Arne Potreck, Sebastian C. Niesporek, Myriam Keymling, Armin M. Nagel, Martin Bendszus, Wolfgang Wick, Mark E. Ladd, Heinz-Peter Schlemmer, Angelika Hoffmann, Tanja Platt and Daniel Paech

MARC

LEADER 00000caa a2200000 c 4500
001 1860203280
003 DE-627
005 20240307053320.0
007 cr uuu---uuuuu
008 230925s2023 xx |||||o 00| ||eng c
024 7 |a 10.3389/fnins.2023.1186558  |2 doi 
035 |a (DE-627)1860203280 
035 |a (DE-599)KXP1860203280 
035 |a (OCoLC)1425212023 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ebersberger, Louise  |e VerfasserIn  |0 (DE-588)1303838753  |0 (DE-627)1860207065  |4 aut 
245 1 0 |a First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke  |c Louise Ebersberger, Fabian J. Kratzer, Arne Potreck, Sebastian C. Niesporek, Myriam Keymling, Armin M. Nagel, Martin Bendszus, Wolfgang Wick, Mark E. Ladd, Heinz-Peter Schlemmer, Angelika Hoffmann, Tanja Platt and Daniel Paech 
264 1 |c 15 June 2023 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.09.2023 
520 |a Dynamic oxygen-17 (17O) magnetic resonance imaging (MRI) is an imaging method that enables a direct and non-invasive assessment of cerebral oxygen metabolism and thus potentially the distinction between viable and non-viable tissue employing a three-phase inhalation experiment. The purpose of this investigation was the first application of dynamic 17O MRI at 7 Tesla (T) in a patient with stroke. In this proof-of-concept experiment, dynamic 17O MRI was applied during 17O inhalation in a patient with early subacute stroke. The analysis of the relative 17O water (H217O) signal for the affected stroke region compared to the healthy contralateral side revealed no significant difference. However, the technical feasibility of 17O MRI has been demonstrated paving the way for future investigations in neurovascular diseases. 
700 1 |a Kratzer, Fabian  |d 1993-  |e VerfasserIn  |0 (DE-588)1249932068  |0 (DE-627)1786560240  |4 aut 
700 1 |a Potreck, Arne  |e VerfasserIn  |0 (DE-588)1031679790  |0 (DE-627)737108886  |0 (DE-576)379370638  |4 aut 
700 1 |a Niesporek, Sebastian  |d 1988-  |e VerfasserIn  |0 (DE-588)1150791357  |0 (DE-627)1011040093  |0 (DE-576)497252643  |4 aut 
700 1 |a Keymling, Myriam  |e VerfasserIn  |0 (DE-588)127338928X  |0 (DE-627)1823185029  |4 aut 
700 1 |a Nagel, Armin Michael  |e VerfasserIn  |0 (DE-588)13791878X  |0 (DE-627)598153276  |0 (DE-576)305872141  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Wick, Wolfgang  |d 1970-  |e VerfasserIn  |0 (DE-588)120297736  |0 (DE-627)080586929  |0 (DE-576)186221320  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Hoffmann, Angelika  |e VerfasserIn  |0 (DE-588)1036902080  |0 (DE-627)751406759  |0 (DE-576)38950372X  |4 aut 
700 1 |a Platt, Tanja  |d 1988-  |e VerfasserIn  |0 (DE-588)1153164434  |0 (DE-627)1014584884  |0 (DE-576)500111391  |4 aut 
700 1 |a Paech, Daniel  |d 1986-  |e VerfasserIn  |0 (DE-588)1080278214  |0 (DE-627)844124893  |0 (DE-576)453464742  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in neuroscience  |d Lausanne : Frontiers Research Foundation, 2007  |g 17(2023) vom: Juni, Artikel-ID 1186558, Seite 1-7  |h Online-Ressource  |w (DE-627)55908109X  |w (DE-600)2411902-7  |w (DE-576)281378959  |x 1662-453X  |7 nnas  |a First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke 
773 1 8 |g volume:17  |g year:2023  |g month:06  |g elocationid:1186558  |g pages:1-7  |g extent:7  |a First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke 
856 4 0 |u https://doi.org/10.3389/fnins.2023.1186558  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.frontiersin.org/articles/10.3389/fnins.2023.1186558  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230925 
993 |a Article 
994 |a 2023 
998 |g 1080278214  |a Paech, Daniel  |m 1080278214:Paech, Daniel  |d 50000  |e 50000PP1080278214  |k 0/50000/  |p 13  |y j 
998 |g 1153164434  |a Platt, Tanja  |m 1153164434:Platt, Tanja  |d 50000  |e 50000PP1153164434  |k 0/50000/  |p 12 
998 |g 1036902080  |a Hoffmann, Angelika  |m 1036902080:Hoffmann, Angelika  |d 50000  |e 50000PH1036902080  |k 0/50000/  |p 11 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 10 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |e 130000PL108120964X  |k 0/130000/  |p 9 
998 |g 120297736  |a Wick, Wolfgang  |m 120297736:Wick, Wolfgang  |d 910000  |d 911100  |e 910000PW120297736  |e 911100PW120297736  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 13791878X  |a Nagel, Armin Michael  |m 13791878X:Nagel, Armin Michael  |d 50000  |e 50000PN13791878X  |k 0/50000/  |p 6 
998 |g 127338928X  |a Keymling, Myriam  |m 127338928X:Keymling, Myriam  |d 50000  |e 50000PK127338928X  |k 0/50000/  |p 5 
998 |g 1150791357  |a Niesporek, Sebastian  |m 1150791357:Niesporek, Sebastian  |d 50000  |e 50000PN1150791357  |k 0/50000/  |p 4 
998 |g 1031679790  |a Potreck, Arne  |m 1031679790:Potreck, Arne  |d 910000  |d 911100  |e 910000PP1031679790  |e 911100PP1031679790  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1249932068  |a Kratzer, Fabian  |m 1249932068:Kratzer, Fabian  |d 50000  |e 50000PK1249932068  |k 0/50000/  |p 2 
999 |a KXP-PPN1860203280  |e 4378803569 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"7 S."}],"recId":"1860203280","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 25.09.2023"],"title":[{"title_sort":"First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke","title":"First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke"}],"origin":[{"dateIssuedDisp":"15 June 2023","dateIssuedKey":"2023"}],"person":[{"display":"Ebersberger, Louise","role":"aut","given":"Louise","family":"Ebersberger"},{"family":"Kratzer","given":"Fabian","role":"aut","display":"Kratzer, Fabian"},{"given":"Arne","role":"aut","family":"Potreck","display":"Potreck, Arne"},{"display":"Niesporek, Sebastian","family":"Niesporek","given":"Sebastian","role":"aut"},{"display":"Keymling, Myriam","given":"Myriam","role":"aut","family":"Keymling"},{"family":"Nagel","given":"Armin Michael","role":"aut","display":"Nagel, Armin Michael"},{"display":"Bendszus, Martin","given":"Martin","role":"aut","family":"Bendszus"},{"display":"Wick, Wolfgang","given":"Wolfgang","role":"aut","family":"Wick"},{"display":"Ladd, Mark E.","family":"Ladd","given":"Mark E.","role":"aut"},{"given":"Heinz-Peter","role":"aut","family":"Schlemmer","display":"Schlemmer, Heinz-Peter"},{"display":"Hoffmann, Angelika","given":"Angelika","role":"aut","family":"Hoffmann"},{"display":"Platt, Tanja","family":"Platt","role":"aut","given":"Tanja"},{"display":"Paech, Daniel","family":"Paech","given":"Daniel","role":"aut"}],"relHost":[{"title":[{"title_sort":"Frontiers in neuroscience","title":"Frontiers in neuroscience"}],"note":["Gesehen am 04.06.20"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"publisher":"Frontiers Research Foundation","dateIssuedKey":"2007","dateIssuedDisp":"2007-","publisherPlace":"Lausanne"}],"disp":"First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute strokeFrontiers in neuroscience","recId":"55908109X","physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"7","volume":"17","text":"17(2023) vom: Juni, Artikel-ID 1186558, Seite 1-7","year":"2023","pages":"1-7"},"id":{"eki":["55908109X"],"issn":["1662-453X"],"zdb":["2411902-7"]},"pubHistory":["1.2007 -"],"name":{"displayForm":["Frontiers Research Foundation"]}}],"id":{"eki":["1860203280"],"doi":["10.3389/fnins.2023.1186558"]},"name":{"displayForm":["Louise Ebersberger, Fabian J. Kratzer, Arne Potreck, Sebastian C. Niesporek, Myriam Keymling, Armin M. Nagel, Martin Bendszus, Wolfgang Wick, Mark E. Ladd, Heinz-Peter Schlemmer, Angelika Hoffmann, Tanja Platt and Daniel Paech"]}} 
SRT |a EBERSBERGEFIRSTAPPLI1520