Pancreatic CT perfusion: quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parameters

Background: This study provides a quantitative meta-analysis of pancreatic CT perfusion studies, investigating choice of study parameters, ability for quantitative discrimination of pancreatic diseases, and influence of acquisition and reconstruction parameters on reported results. Methods: Based on...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Skornitzke, Stephan (VerfasserIn) , Vats, Neha (VerfasserIn) , Mayer, Philipp (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Stiller, Wolfram (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2023
In: Insights into imaging
Year: 2023, Jahrgang: 14, Pages: 1-14
ISSN:1869-4101
DOI:10.1186/s13244-023-01471-0
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1186/s13244-023-01471-0
Verlag, kostenfrei, Volltext: https://insightsimaging.springeropen.com/articles/10.1186/s13244-023-01471-0
Volltext
Verfasserangaben:Stephan Skornitzke, Neha Vats, Philipp Mayer, Hans-Ulrich Kauczor and Wolfram Stiller

MARC

LEADER 00000caa a2200000 c 4500
001 1860270964
003 DE-627
005 20240307053102.0
007 cr uuu---uuuuu
008 230926s2023 xx |||||o 00| ||eng c
024 7 |a 10.1186/s13244-023-01471-0  |2 doi 
035 |a (DE-627)1860270964 
035 |a (DE-599)KXP1860270964 
035 |a (OCoLC)1425210982 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
245 1 0 |a Pancreatic CT perfusion  |b quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parameters  |c Stephan Skornitzke, Neha Vats, Philipp Mayer, Hans-Ulrich Kauczor and Wolfram Stiller 
264 1 |c 2023 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 21. Juli 2023 
500 |a Gesehen am 26.09.2023 
520 |a Background: This study provides a quantitative meta-analysis of pancreatic CT perfusion studies, investigating choice of study parameters, ability for quantitative discrimination of pancreatic diseases, and influence of acquisition and reconstruction parameters on reported results. Methods: Based on a PubMed search with key terms ‘pancreas’ or ‘pancreatic,’ ‘dynamic’ or ‘perfusion,’ and ‘computed tomography’ or ‘CT,’ 491 articles published between 1982 and 2020 were screened for inclusion in the study. Inclusion criteria were: reported original data, human subjects, five or more datasets, measurements of pancreas or pancreatic pathologies, and reported quantitative perfusion parameters. Study parameters and reported quantitative measurements were extracted, and heterogeneity of study parameters and trends over time are analyzed. Pooled data were tested with weighted ANOVA and ANCOVA models for differences in perfusion results between normal pancreas, pancreatitis, PDAC (pancreatic ductal adenocarcinoma), and non-PDAC (e.g., neuroendocrine tumors, insulinomas) and based on study parameters. Results: Reported acquisition parameters were heterogeneous, except for contrast agent amount and injection rate. Tube potential and slice thickness decreased, whereas tube current time product and scan coverage increased over time. Blood flow and blood volume showed significant differences between pathologies (both p < 0.001), unlike permeability (p = 0.11). Study parameters showed a significant effect on reported quantitative measurements (p < 0.05). Conclusions: Significant differences in perfusion measurements between pathologies could be shown for pooled data despite observed heterogeneity in study parameters. Statistical analysis indicates most influential parameters for future optimization and standardization of acquisition protocols. 
650 4 |a Pancreas 
650 4 |a Perfusion imaging 
650 4 |a X-ray computed tomography 
700 1 |a Vats, Neha  |d 1993-  |e VerfasserIn  |0 (DE-588)1283965690  |0 (DE-627)1839656263  |4 aut 
700 1 |a Mayer, Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1066605440  |0 (DE-627)817714758  |0 (DE-576)426052250  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
773 0 8 |i Enthalten in  |t Insights into imaging  |d Berlin : Springer, 2010  |g 14(2023), Artikel-ID 132, Seite 1-14  |h Online-Ressource  |w (DE-627)621547425  |w (DE-600)2543323-4  |w (DE-576)320937771  |x 1869-4101  |7 nnas  |a Pancreatic CT perfusion quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parameters 
773 1 8 |g volume:14  |g year:2023  |g elocationid:132  |g pages:1-14  |g extent:14  |a Pancreatic CT perfusion quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parameters 
856 4 0 |u https://doi.org/10.1186/s13244-023-01471-0  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://insightsimaging.springeropen.com/articles/10.1186/s13244-023-01471-0  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230926 
993 |a Article 
994 |a 2023 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |d 50000  |e 910000PS105822672X  |e 911400PS105822672X  |e 50000PS105822672X  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 5  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1066605440  |a Mayer, Philipp  |m 1066605440:Mayer, Philipp  |d 910000  |d 911400  |e 910000PM1066605440  |e 911400PM1066605440  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 1283965690  |a Vats, Neha  |m 1283965690:Vats, Neha  |d 910000  |d 911400  |e 910000PV1283965690  |e 911400PV1283965690  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 50000  |e 50000PS1110072589  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1860270964  |e 437897794X 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Veröffentlicht: 21. Juli 2023","Gesehen am 26.09.2023"],"recId":"1860270964","person":[{"role":"aut","family":"Skornitzke","given":"Stephan","display":"Skornitzke, Stephan"},{"display":"Vats, Neha","given":"Neha","role":"aut","family":"Vats"},{"family":"Mayer","role":"aut","given":"Philipp","display":"Mayer, Philipp"},{"given":"Hans-Ulrich","display":"Kauczor, Hans-Ulrich","role":"aut","family":"Kauczor"},{"family":"Stiller","role":"aut","display":"Stiller, Wolfram","given":"Wolfram"}],"name":{"displayForm":["Stephan Skornitzke, Neha Vats, Philipp Mayer, Hans-Ulrich Kauczor and Wolfram Stiller"]},"language":["eng"],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"2023"}],"relHost":[{"title":[{"title":"Insights into imaging","title_sort":"Insights into imaging"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2543323-4"],"issn":["1869-4101"],"eki":["621547425"]},"origin":[{"publisher":"Springer","dateIssuedDisp":"2010-","dateIssuedKey":"2010","publisherPlace":"Berlin ; Heidelberg"}],"recId":"621547425","disp":"Pancreatic CT perfusion quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parametersInsights into imaging","type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"part":{"volume":"14","year":"2023","extent":"14","pages":"1-14","text":"14(2023), Artikel-ID 132, Seite 1-14"},"note":["Gesehen am 25.06.13"],"pubHistory":["1.2010 -"]}],"id":{"doi":["10.1186/s13244-023-01471-0"],"eki":["1860270964"]},"physDesc":[{"extent":"14 S."}],"title":[{"title_sort":"Pancreatic CT perfusion","subtitle":"quantitative meta-analysis of disease discrimination, protocol development, and effect of CT parameters","title":"Pancreatic CT perfusion"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a SKORNITZKEPANCREATIC2023