DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation: stroke, systemic or venous thromboembolism

In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-cen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Margetić, Sandra (VerfasserIn) , Ćelap, Ivana (VerfasserIn) , Huzjan, Arijana Lovrenčić (VerfasserIn) , Puretić, Marijana Bosnar (VerfasserIn) , Goreta, Sandra Šupraha (VerfasserIn) , Glojnarić, Anesa Čajević (VerfasserIn) , Brkljačić, Diana Delić (VerfasserIn) , Mioč, Pavao (VerfasserIn) , Harenberg, Job (VerfasserIn) , Hetjens, Svetlana (VerfasserIn) , Weiß, Christel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 10. März 2022
In: Thrombosis and haemostasis
Year: 2022, Jahrgang: 122, Heft: 9, Pages: 1542-1548
ISSN:2567-689X
DOI:10.1055/a-1753-2748
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1055/a-1753-2748
Verlag, kostenfrei, Volltext: http://www.thieme.connect.de/DOI/DOI?10.1055/a-1753-2748
Volltext
Verfasserangaben:Sandra Margetić, Ivana Ćelap, Arijana Lovrenčić Huzjan, Marijana Bosnar Puretić, Sandra Šupraha Goreta, Anesa Čajević Glojnarić, Diana Delić Brkljačić, Pavao Mioč, Job Harenberg, Svetlana Hetjens, Christel Weiss

MARC

LEADER 00000caa a2200000 c 4500
001 186028809X
003 DE-627
005 20240307083628.0
007 cr uuu---uuuuu
008 230926s2022 xx |||||o 00| ||eng c
024 7 |a 10.1055/a-1753-2748  |2 doi 
035 |a (DE-627)186028809X 
035 |a (DE-599)KXP186028809X 
035 |a (OCoLC)1425216617 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Margetić, Sandra  |e VerfasserIn  |0 (DE-588)1304004686  |0 (DE-627)1860288979  |4 aut 
245 1 0 |a DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation  |b stroke, systemic or venous thromboembolism  |c Sandra Margetić, Ivana Ćelap, Arijana Lovrenčić Huzjan, Marijana Bosnar Puretić, Sandra Šupraha Goreta, Anesa Čajević Glojnarić, Diana Delić Brkljačić, Pavao Mioč, Job Harenberg, Svetlana Hetjens, Christel Weiss 
264 1 |c 10. März 2022 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Die Studie war Teil des Forschungsprojekts mit dem Titel "“New oral anticoagulants: relationship between drug concentration and anticoagulant effect” (IP-2016-06-8208), das von der Kroatischen Wissenschaftsstiftung finanziert wurde 
500 |a Gesehen am 26.09.2023 
520 |a In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-center cohort study included consecutive patients treated with an oral direct factor Xa inhibitor (DXI) (apixaban, n= 31, rivaroxaban, n = 53) and direct thrombin inhibitor (DTI) (dabigatran, n = 44). We aimed to define the negative predictive value (NPV) and other statistical parameters of detecting DXIs and DTIs by DOAC Dipstick at plasma concentrations of ≥30 ng/mL. We also determined the best-fit threshold plasma levels using chromogenic substrate assays by logistic regression analysis. Between July 2020 and July 2021, 128 eligible patients (mean age 66 years, 55 females) were included into the study. The NPVs and sensitivities for DXI and DTI of DOAC Dipstick were 100% at ≥30 ng/mL plasma, for specificities 6 and 21% and for positive predictive values 62 and 72%, respectively. All diagnostic statistical tests improved to values between 86 and 100% at best-fitting plasma thresholds of ≥14 ng/mL for DXI and ≥19 ng/mL for DTI. Visual analysis using the DOAC Dipstick was 100% in agreement with that of the optoelectronic DOASENSE Reader for all the three DOACs. DOAC Dipstick testing can reliably exclude the presence of DOACs in urine samples at best-fitting thresholds of >14 and >19 ng/mL in plasma. The performance of the DOAC Dipstick at detecting lower DOAC concentrations in plasma requires confirmation. 
700 1 |a Ćelap, Ivana  |e VerfasserIn  |4 aut 
700 1 |a Huzjan, Arijana Lovrenčić  |e VerfasserIn  |4 aut 
700 1 |a Puretić, Marijana Bosnar  |e VerfasserIn  |4 aut 
700 1 |a Goreta, Sandra Šupraha  |e VerfasserIn  |4 aut 
700 1 |a Glojnarić, Anesa Čajević  |e VerfasserIn  |4 aut 
700 1 |a Brkljačić, Diana Delić  |e VerfasserIn  |4 aut 
700 1 |a Mioč, Pavao  |e VerfasserIn  |4 aut 
700 1 |a Harenberg, Job  |d 1950-  |e VerfasserIn  |0 (DE-588)108825507  |0 (DE-627)655891498  |0 (DE-576)339563745  |4 aut 
700 1 |a Hetjens, Svetlana  |d 1983-  |e VerfasserIn  |0 (DE-588)1031801979  |0 (DE-627)737600284  |0 (DE-576)379534223  |4 aut 
700 1 |a Weiß, Christel  |d 1958-  |e VerfasserIn  |0 (DE-588)123287707  |0 (DE-627)082463417  |0 (DE-576)168356104  |4 aut 
773 0 8 |i Enthalten in  |t Thrombosis and haemostasis  |d Stuttgart : Thieme, 1976  |g 122(2022), 9 vom: Sept., Seite 1542-1548  |h Online-Ressource  |w (DE-627)302723188  |w (DE-600)1492370-1  |w (DE-576)079877362  |x 2567-689X  |7 nnas  |a DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation stroke, systemic or venous thromboembolism 
773 1 8 |g volume:122  |g year:2022  |g number:9  |g month:09  |g pages:1542-1548  |g extent:7  |a DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation stroke, systemic or venous thromboembolism 
856 4 0 |u https://doi.org/10.1055/a-1753-2748  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://www.thieme.connect.de/DOI/DOI?10.1055/a-1753-2748  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230926 
993 |a Article 
994 |a 2022 
998 |g 123287707  |a Weiß, Christel  |m 123287707:Weiß, Christel  |d 60000  |d 60200  |d 60250  |d 60000  |e 60000PW123287707  |e 60200PW123287707  |e 60250PW123287707  |e 60000PW123287707  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |k 0/60000/  |p 11  |y j 
998 |g 1031801979  |a Hetjens, Svetlana  |m 1031801979:Hetjens, Svetlana  |d 60000  |d 60200  |d 60250  |e 60000PH1031801979  |e 60200PH1031801979  |e 60250PH1031801979  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |p 10 
998 |g 108825507  |a Harenberg, Job  |m 108825507:Harenberg, Job  |d 60000  |e 60000PH108825507  |k 0/60000/  |p 9 
999 |a KXP-PPN186028809X  |e 4379020290 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Margetić, Sandra","family":"Margetić","given":"Sandra","role":"aut"},{"display":"Ćelap, Ivana","family":"Ćelap","given":"Ivana","role":"aut"},{"display":"Huzjan, Arijana Lovrenčić","family":"Huzjan","role":"aut","given":"Arijana Lovrenčić"},{"display":"Puretić, Marijana Bosnar","family":"Puretić","role":"aut","given":"Marijana Bosnar"},{"given":"Sandra Šupraha","role":"aut","family":"Goreta","display":"Goreta, Sandra Šupraha"},{"family":"Glojnarić","display":"Glojnarić, Anesa Čajević","given":"Anesa Čajević","role":"aut"},{"role":"aut","given":"Diana Delić","display":"Brkljačić, Diana Delić","family":"Brkljačić"},{"given":"Pavao","role":"aut","family":"Mioč","display":"Mioč, Pavao"},{"role":"aut","given":"Job","family":"Harenberg","display":"Harenberg, Job"},{"display":"Hetjens, Svetlana","family":"Hetjens","role":"aut","given":"Svetlana"},{"role":"aut","given":"Christel","display":"Weiß, Christel","family":"Weiß"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"subtitle":"stroke, systemic or venous thromboembolism","title_sort":"DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation","title":"DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation"}],"note":["Die Studie war Teil des Forschungsprojekts mit dem Titel \"“New oral anticoagulants: relationship between drug concentration and anticoagulant effect” (IP-2016-06-8208), das von der Kroatischen Wissenschaftsstiftung finanziert wurde","Gesehen am 26.09.2023"],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"10. März 2022"}],"id":{"doi":["10.1055/a-1753-2748"],"eki":["186028809X"]},"recId":"186028809X","relHost":[{"title":[{"title":"Thrombosis and haemostasis","title_sort":"Thrombosis and haemostasis","subtitle":"journal of the International Society on Thrombosis and Haemostasis"}],"note":["Gesehen am 15.06.2018"],"origin":[{"publisherPlace":"Stuttgart ; Stuttgart","dateIssuedKey":"1976","publisher":"Thieme ; Schattauer","dateIssuedDisp":"1976-"}],"pubHistory":["35.1976 -"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"DOAC dipstick testing can reliably exclude the presence of clinically relevant DOAC concentrations in circulation stroke, systemic or venous thromboembolismThrombosis and haemostasis","physDesc":[{"extent":"Online-Ressource"}],"recId":"302723188","id":{"doi":["10.1055/s-00035024"],"zdb":["1492370-1"],"issn":["2567-689X"],"eki":["302723188"]},"language":["eng"],"part":{"issue":"9","text":"122(2022), 9 vom: Sept., Seite 1542-1548","pages":"1542-1548","year":"2022","extent":"7","volume":"122"}}],"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Sandra Margetić, Ivana Ćelap, Arijana Lovrenčić Huzjan, Marijana Bosnar Puretić, Sandra Šupraha Goreta, Anesa Čajević Glojnarić, Diana Delić Brkljačić, Pavao Mioč, Job Harenberg, Svetlana Hetjens, Christel Weiss"]}} 
SRT |a MARGETICSADOACDIPSTI1020