Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases.

BACKGROUND: Ultrasound-guided renal biopsy with an automated spring-loaded biopsy device has become the standard method for kidney biopsy. Information on the success rate and safety of the routine use of this procedure from large series is not available. Such information is of interest for cost bene...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hergesell, Olaf (VerfasserIn) , Felten, Helmut (VerfasserIn) , Andrassy, Konrad (VerfasserIn) , Kühn, Karlwilhelm (VerfasserIn) , Ritz, Eberhard (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 01 April 1998
In: Nephrology, dialysis, transplantation
Year: 1998, Jahrgang: 13, Heft: 4, Pages: 975-977
ISSN:1460-2385
DOI:10.1093/ndt/13.4.975
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1093/ndt/13.4.975
Volltext
Verfasserangaben:O Hergesell, H Felten, K Andrassy, K Kühn, E Ritz

MARC

LEADER 00000caa a2200000 c 4500
001 1860392652
003 DE-627
005 20240311143443.0
007 cr uuu---uuuuu
008 230927s1998 xx |||||o 00| ||eng c
024 7 |a 10.1093/ndt/13.4.975  |2 doi 
035 |a (DE-627)1860392652 
035 |a (DE-599)KXP1860392652 
035 |a (OCoLC)1425879453 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hergesell, Olaf  |d 1966-  |e VerfasserIn  |0 (DE-588)121740188  |0 (DE-627)705635600  |0 (DE-576)292860382  |4 aut 
245 1 0 |a Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases.  |c O Hergesell, H Felten, K Andrassy, K Kühn, E Ritz 
264 1 |c 01 April 1998 
300 |a 3 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.09.2023 
520 |a BACKGROUND: Ultrasound-guided renal biopsy with an automated spring-loaded biopsy device has become the standard method for kidney biopsy. Information on the success rate and safety of the routine use of this procedure from large series is not available. Such information is of interest for cost benefit considerations and for medicolegal purposes. We performed an audit of this procedure. SUBJECTS AND METHODS: From January 1993 to June 1997, 1090 percutaneous renal biopsies were performed in the renal units of Heidelberg (n = 557) and Karlsruhe (n = 533) using a spring-loaded biopsy device (Biopty; Radiplast AB, Uppsala, Sweden). After intensive local disinfection, biopsies were performed under local anaesthesia and direct visualization by ultrasound (Sonolayer SSH-140 A, Toshiba Inc., Japan). A puncturing adaptor was used (model UAGV 009 A, Toshiba, Japan). Of the 1090 biopsies 114 (10.4%) were performed on renal allografts and 976 (89.6%) on orthotopic kidneys. Biopsies were performed only if patients were strictly normotensive (<140/90 mmHg) and had normal coagulation parameters (PT, PTT, factor VIII, thrombocyte count, and bleeding time). All patients had been advised not to take aspirin or non-steroidal antiinflammatory agents for at least 5 days prior biopsy. We analysed (1) yield of diagnostically useful material, and (2) frequency of postbiopsy complications (e.g. macrohaematuria, haematoma, infections, and AV fistula). RESULTS: Except for one case requiring interventional radiology because of persisting blood loss and three cases requiring blood transfusions, no serious complications were seen in the 1090 consecutive renal biopsies, e.g. death, loss of kidney, life-threatening haemorrhage, or persisting haemodynamically relevant AV fistulae. The frequency of minor haematoma with an extension >2 x 2 cm, but no significant decrease of haemoglobin, was 2.2% (25/1090). Self-limited mild macrohaematuria occurred in 0.8% (9/1090). The incidence of small, haemodynamically irrelevant AV fistulae detected by Doppler ultrasound was 9% (48/533). Sufficient tissue for reliable histopathological diagnosis was obtained in almost all cases (1077/1090 = 98.8%). The median number of glomeruli per biopsy sample was 9 (range 1-37). CONCLUSION: If contraindications, especially high blood pressure and abnormal haemostasis, are respected, ultrasound-guided percutaneous renal biopsy with an automated biopsy device is safe. Skilled operators obtain satisfactory amounts of kidney tissue in almost all cases. 
700 1 |a Felten, Helmut  |d 1923-  |e VerfasserIn  |0 (DE-588)173697798  |0 (DE-627)698604652  |0 (DE-576)13453946X  |4 aut 
700 1 |a Andrassy, Konrad  |e VerfasserIn  |0 (DE-588)1076338119  |0 (DE-627)834722216  |0 (DE-576)445217197  |4 aut 
700 1 |a Kühn, Karlwilhelm  |d 1943-  |e VerfasserIn  |0 (DE-588)1146593791  |0 (DE-627)1008066117  |0 (DE-576)188529896  |4 aut 
700 1 |a Ritz, Eberhard  |d 1938-2023  |e VerfasserIn  |0 (DE-588)106673386  |0 (DE-627)610528866  |0 (DE-576)311552501  |4 aut 
773 0 8 |i Enthalten in  |t Nephrology, dialysis, transplantation  |d Oxford : Oxford Univ. Press, 1986  |g 13(1998), 4, Seite 975-977  |h Online-Ressource  |w (DE-627)265778395  |w (DE-600)1465709-0  |w (DE-576)079420079  |x 1460-2385  |7 nnas  |a Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases. 
773 1 8 |g volume:13  |g year:1998  |g number:4  |g pages:975-977  |g extent:3  |a Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases. 
856 4 0 |u https://doi.org/10.1093/ndt/13.4.975  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230927 
993 |a Article 
994 |a 1998 
998 |g 106673386  |a Ritz, Eberhard  |m 106673386:Ritz, Eberhard  |d 910000  |d 910100  |e 910000PR106673386  |e 910100PR106673386  |k 0/910000/  |k 1/910000/910100/  |p 5  |y j 
998 |g 1146593791  |a Kühn, Karlwilhelm  |m 1146593791:Kühn, Karlwilhelm  |d 910000  |d 910100  |e 910000PK1146593791  |e 910100PK1146593791  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 1076338119  |a Andrassy, Konrad  |m 1076338119:Andrassy, Konrad  |d 910000  |d 910100  |e 910000PA1076338119  |e 910100PA1076338119  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 121740188  |a Hergesell, Olaf  |m 121740188:Hergesell, Olaf  |d 910000  |d 910100  |e 910000PH121740188  |e 910100PH121740188  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1860392652  |e 4379560813 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"origin":[{"dateIssuedDisp":"1986-","dateIssuedKey":"1986","publisherPlace":"Oxford","publisher":"Oxford Univ. Press"}],"title":[{"title":"Nephrology, dialysis, transplantation","title_sort":"Nephrology, dialysis, transplantation"}],"titleAlt":[{"title":"Nephrology, dialysis, transplantation online"}],"language":["eng"],"part":{"issue":"4","year":"1998","volume":"13","extent":"3","pages":"975-977","text":"13(1998), 4, Seite 975-977"},"disp":"Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases.Nephrology, dialysis, transplantation","type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"265778395","id":{"issn":["1460-2385"],"zdb":["1465709-0"],"eki":["265778395"]},"pubHistory":["1.1986 -"],"note":["Gesehen am 01-04-14"],"physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedDisp":"01 April 1998","dateIssuedKey":"1998"}],"title":[{"title_sort":"Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases.","title":"Safety of ultrasound-guided percutaneous renal biopsy-retrospective analysis of 1090 consecutive cases."}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1860392652","id":{"doi":["10.1093/ndt/13.4.975"],"eki":["1860392652"]},"note":["Gesehen am 27.09.2023"],"physDesc":[{"extent":"3 S."}],"name":{"displayForm":["O Hergesell, H Felten, K Andrassy, K Kühn, E Ritz"]},"person":[{"family":"Hergesell","given":"Olaf","role":"aut","display":"Hergesell, Olaf","roleDisplay":"VerfasserIn"},{"family":"Felten","given":"Helmut","roleDisplay":"VerfasserIn","role":"aut","display":"Felten, Helmut"},{"family":"Andrassy","given":"Konrad","roleDisplay":"VerfasserIn","role":"aut","display":"Andrassy, Konrad"},{"family":"Kühn","given":"Karlwilhelm","display":"Kühn, Karlwilhelm","role":"aut","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","role":"aut","display":"Ritz, Eberhard","given":"Eberhard","family":"Ritz"}]} 
SRT |a HERGESELLOSAFETYOFUL0119