Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system
The fixed neutral position of conventional prosthetic feet causes difficulties for transtibial amputees (TTAs) when walking on ramps. New microprocessor-controlled prosthetic ankles such as the Proprio-Foot® (Össur) aim to reduce these difficulties by modifying the prosthetic ankle angle according...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
10 May 2010
|
| In: |
Gait & posture
Year: 2010, Jahrgang: 32, Heft: 2, Pages: 191-198 |
| ISSN: | 1879-2219 |
| DOI: | 10.1016/j.gaitpost.2010.04.011 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.gaitpost.2010.04.011 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0966636210001177 |
| Verfasserangaben: | Laetitia Fradet, Merkur Alimusaj, Frank Braatz, Sebastian I. Wolf |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1865874728 | ||
| 003 | DE-627 | ||
| 005 | 20240311122806.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 231017s2010 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.gaitpost.2010.04.011 |2 doi | |
| 035 | |a (DE-627)1865874728 | ||
| 035 | |a (DE-599)KXP1865874728 | ||
| 035 | |a (OCoLC)1425873463 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Fradet, Laetitia |e VerfasserIn |0 (DE-588)1104403072 |0 (DE-627)861874617 |0 (DE-576)470980303 |4 aut | |
| 245 | 1 | 0 | |a Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system |c Laetitia Fradet, Merkur Alimusaj, Frank Braatz, Sebastian I. Wolf |
| 264 | 1 | |c 10 May 2010 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 17.10.2023 | ||
| 520 | |a The fixed neutral position of conventional prosthetic feet causes difficulties for transtibial amputees (TTAs) when walking on ramps. New microprocessor-controlled prosthetic ankles such as the Proprio-Foot® (Össur) aim to reduce these difficulties by modifying the prosthetic ankle angle according to the gait condition. The purpose of the present investigation was to assess the biomechanical effects of adaptation of the prosthetic ankle on ramp ambulation in TTAs. Sixteen TTAs and 16 controls underwent a conventional 3D gait analysis while walking up and down a ramp. TTAs walked with the prosthetic foot set to a neutral mode angle and set to the adapted mode. Norm distance, sagittal kinematics and kinetics were calculated for comparisons between TTAs and controls. During ramp ascent, the dorsiflexion brought about by the adapted prosthetic ankle reduced the increased knee extension noted on the TTAs’ involved side and the increased plantarflexion on their sound side. During ramp descent, the plantarflexion of the adapted mode increased the adaptation mechanisms observed in TTAs. These findings suggest that the adapted mode leads to more physiologic kinematics and kinetics in the lower limbs in TTAs during ramp ascent but not during ramp descent. However, in the adapted mode, patients reported feeling safer during ramp descent, thus indicating that there might be other safety related measures such as toe-clearance or coefficient of friction influencing this perception. | ||
| 650 | 4 | |a Gait analysis | |
| 650 | 4 | |a Incline | |
| 650 | 4 | |a Microprocessor ankle | |
| 650 | 4 | |a Prosthesis | |
| 650 | 4 | |a Transtibial amputee | |
| 700 | 1 | |a Alimusaj, Merkur |e VerfasserIn |0 (DE-588)1046144685 |0 (DE-627)775784710 |0 (DE-576)39941245X |4 aut | |
| 700 | 1 | |a Braatz, Frank |d 1963- |e VerfasserIn |0 (DE-588)123922135 |0 (DE-627)706474872 |0 (DE-576)293943885 |4 aut | |
| 700 | 1 | |a Wolf, Sebastian Immanuel |d 1965- |e VerfasserIn |0 (DE-588)1051004578 |0 (DE-627)785483861 |0 (DE-576)40544849X |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Gait & posture |d Amsterdam [u.a.] : Elsevier Science, 1993 |g 32(2010), 2 vom: Juni, Seite 191-198 |h Online-Ressource |w (DE-627)306659514 |w (DE-600)1500471-5 |w (DE-576)081986238 |x 1879-2219 |7 nnas |a Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system |
| 773 | 1 | 8 | |g volume:32 |g year:2010 |g number:2 |g month:06 |g pages:191-198 |g extent:8 |a Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.gaitpost.2010.04.011 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0966636210001177 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20231017 | ||
| 993 | |a Article | ||
| 994 | |a 2010 | ||
| 998 | |g 1051004578 |a Wolf, Sebastian Immanuel |m 1051004578:Wolf, Sebastian Immanuel |d 910000 |d 911460 |e 910000PW1051004578 |e 911460PW1051004578 |k 0/910000/ |k 1/910000/911460/ |p 4 |y j | ||
| 998 | |g 123922135 |a Braatz, Frank |m 123922135:Braatz, Frank |d 910000 |d 911460 |e 910000PB123922135 |e 911460PB123922135 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1046144685 |a Alimusaj, Merkur |m 1046144685:Alimusaj, Merkur |d 910000 |d 911460 |e 910000PA1046144685 |e 911460PA1046144685 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 998 | |g 1104403072 |a Fradet, Laetitia |m 1104403072:Fradet, Laetitia |d 910000 |d 911460 |e 910000PF1104403072 |e 911460PF1104403072 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1865874728 |e 4390930109 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"title_sort":"Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system","title":"Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system"}],"relHost":[{"part":{"text":"32(2010), 2 vom: Juni, Seite 191-198","pages":"191-198","issue":"2","extent":"8","year":"2010","volume":"32"},"pubHistory":["1.1993 - 42.2015; Vol. 43.2016 -"],"id":{"issn":["1879-2219"],"zdb":["1500471-5"],"eki":["306659514"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"official journal of North American Society of Gait and Clinical Movement Analysis, European Society of Movement Analysis in Children"},{"title":"official journal of Gait and Clinical Movement Analysis Society, European Society of Movement Analysis in Adults and Children, Società Italiana di Analisi del Movimento in Clinica"},{"title":"Gait and posture"}],"recId":"306659514","origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1993","dateIssuedDisp":"1993-","publisher":"Elsevier Science"}],"language":["eng"],"title":[{"title":"Gait & posture","subtitle":"official journal of Gait and Clinical Movement Analysis Society (GCMAS) and European Society of Movement Analysis in Adults and Children (ESMAC)","title_sort":"Gait & posture"}],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 16.11.2020","Ungezählte Beil.: Suppl. mit Kongressveröffentlichungen der hrsg. Organisationen"],"disp":"Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot systemGait & posture"}],"physDesc":[{"extent":"8 S."}],"id":{"eki":["1865874728"],"doi":["10.1016/j.gaitpost.2010.04.011"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"role":"aut","display":"Fradet, Laetitia","given":"Laetitia","family":"Fradet"},{"role":"aut","display":"Alimusaj, Merkur","given":"Merkur","family":"Alimusaj"},{"given":"Frank","family":"Braatz","role":"aut","display":"Braatz, Frank"},{"role":"aut","display":"Wolf, Sebastian Immanuel","given":"Sebastian Immanuel","family":"Wolf"}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"10 May 2010"}],"note":["Gesehen am 17.10.2023"],"recId":"1865874728","name":{"displayForm":["Laetitia Fradet, Merkur Alimusaj, Frank Braatz, Sebastian I. Wolf"]}} | ||
| SRT | |a FRADETLAETBIOMECHANI1020 | ||