Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT
Objectives Virtual non-calcium (VNCa) images could improve assessment of plasma cell dyscrasias by enhancing visibility of bone marrow. Thus, VNCa images from dual-layer spectral CT (DLCT) were evaluated at different calcium suppression (CaSupp) indices, correlating results with apparent diffusion c...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
30 March 2021
|
| In: |
European radiology
Year: 2021, Jahrgang: 31, Heft: 10, Pages: 7664-7673 |
| ISSN: | 1432-1084 |
| DOI: | 10.1007/s00330-021-07821-0 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00330-021-07821-0 Verlag, kostenfrei, Volltext: https://link.springer.com/10.1007/s00330-021-07821-0 |
| Verfasserangaben: | S.C. Brandelik, S. Skornitzke, T. Mokry, S. Sauer, W. Stiller, J. Nattenmüller, H.U. Kauczor, T. F. Weber, T.D. Do |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1865943843 | ||
| 003 | DE-627 | ||
| 005 | 20240306114914.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 231017s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00330-021-07821-0 |2 doi | |
| 035 | |a (DE-627)1865943843 | ||
| 035 | |a (DE-599)KXP1865943843 | ||
| 035 | |a (OCoLC)1425062904 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Brandelik, Simone Christine |d 1989- |e VerfasserIn |0 (DE-588)117795561X |0 (DE-627)1049075676 |0 (DE-576)517633655 |4 aut | |
| 245 | 1 | 0 | |a Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT |c S.C. Brandelik, S. Skornitzke, T. Mokry, S. Sauer, W. Stiller, J. Nattenmüller, H.U. Kauczor, T. F. Weber, T.D. Do |
| 264 | 1 | |c 30 March 2021 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 17.10.2023 | ||
| 520 | |a Objectives Virtual non-calcium (VNCa) images could improve assessment of plasma cell dyscrasias by enhancing visibility of bone marrow. Thus, VNCa images from dual-layer spectral CT (DLCT) were evaluated at different calcium suppression (CaSupp) indices, correlating results with apparent diffusion coefficient (ADC) values from MRI. - Methods Thirty-two patients with initial clinical diagnosis of a plasma cell dyscrasia before any chemotherapeutic treatment, who had undergone whole-body low-dose DLCT and MRI within 2 months, were retrospectively enrolled. VNCa images with CaSupp indices ranging from 25 to 95 in steps of 10, conventional CT images, and ADC maps were quantitatively analyzed using region-of-interests in the vertebral bodies C7, T12, L1-L5, and the iliac bone. Independent two-sample t-test, Wilcoxon-signedrank test, Pearson’s correlation, and ROC analysis were performed. - Results Eighteen patients had a non-diffuse, 14 a diffuse infiltration in conventional MRI. A significant difference between diffuse and non-diffuse infiltration was shown for VNCa-CT with CaSupp indices from 55 to 95, for conventional CT, and for ADC (each p < 0.0001). Significant quantitative correlation between VNCa-CT and MRI could be found with strongest correlation at CaSupp index 65 for L3 (r = 0.68, p < 0.0001) and averaged L1-L5 (r = 0.66, p < 0.0001). The optimum CT number cut-off point for differentiation between diffuse and non-diffuse infiltration at CaSupp index 65 for averaged L1-L5 was −1.6 HU (sensitivity 78.6%, specificity 75.0%). - Conclusion Measurements in VNCa-CT showed the highest correlation with ADC at CaSupp index 65. VNCa technique may prove useful for evaluation of bone marrow infiltration if MRI is not feasible. Key Points • VNCa-CT images can support the evaluation of bone marrow infiltration in plasma cell dyscrasias. • VNCa measurements of vertebral bodies show significant correlation with ADC in MRI. • Averaging L1-L5 at CaSupp index 65 allowed quantitative detection of infiltration comparable to MRI ADC. | ||
| 700 | 1 | |a Skornitzke, Stephan |d 1987- |e VerfasserIn |0 (DE-588)1110072589 |0 (DE-627)864783523 |0 (DE-576)475718267 |4 aut | |
| 700 | 1 | |a Mokry, Theresa |e VerfasserIn |0 (DE-588)1074843576 |0 (DE-627)832577901 |0 (DE-576)442986297 |4 aut | |
| 700 | 1 | |a Sauer, Sandra |d 1975- |e VerfasserIn |0 (DE-588)1060031140 |0 (DE-627)799171778 |0 (DE-576)416132855 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 700 | 1 | |a Nattenmüller, Johanna |d 1982- |e VerfasserIn |0 (DE-588)1045589985 |0 (DE-627)774622881 |0 (DE-576)399084215 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Weber, Tim |d 1977- |e VerfasserIn |0 (DE-588)133392694 |0 (DE-627)544045017 |0 (DE-576)299816613 |4 aut | |
| 700 | 1 | |a Do, Thuy |d 1986- |e VerfasserIn |0 (DE-588)1156815800 |0 (DE-627)1019763485 |0 (DE-576)502462205 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European radiology |d Berlin : Springer, 1991 |g 31(2021), 10, Seite 7664-7673 |h Online-Ressource |w (DE-627)268757526 |w (DE-600)1472718-3 |w (DE-576)103868070 |x 1432-1084 |7 nnas |a Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT |
| 773 | 1 | 8 | |g volume:31 |g year:2021 |g number:10 |g pages:7664-7673 |g extent:10 |a Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00330-021-07821-0 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/10.1007/s00330-021-07821-0 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20231017 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1156815800 |a Do, Thuy |m 1156815800:Do, Thuy |d 910000 |d 911400 |e 910000PD1156815800 |e 911400PD1156815800 |k 0/910000/ |k 1/910000/911400/ |p 9 |y j | ||
| 998 | |g 133392694 |a Weber, Tim |m 133392694:Weber, Tim |d 910000 |d 911400 |d 50000 |e 910000PW133392694 |e 911400PW133392694 |e 50000PW133392694 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 8 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ | ||
| 998 | |g 1045589985 |a Nattenmüller, Johanna |m 1045589985:Nattenmüller, Johanna |d 910000 |d 911400 |e 910000PN1045589985 |e 911400PN1045589985 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |d 50000 |e 910000PS105822672X |e 911400PS105822672X |e 50000PS105822672X |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 5 | ||
| 998 | |g 1060031140 |a Sauer, Sandra |m 1060031140:Sauer, Sandra |d 910000 |d 910100 |e 910000PS1060031140 |e 910100PS1060031140 |k 0/910000/ |k 1/910000/910100/ |p 4 | ||
| 998 | |g 1074843576 |a Mokry, Theresa |m 1074843576:Mokry, Theresa |d 910000 |d 911400 |e 910000PM1074843576 |e 911400PM1074843576 |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 1110072589 |a Skornitzke, Stephan |m 1110072589:Skornitzke, Stephan |d 910000 |d 911400 |e 910000PS1110072589 |e 911400PS1110072589 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 117795561X |a Brandelik, Simone Christine |m 117795561X:Brandelik, Simone Christine |d 910000 |d 911400 |e 910000PB117795561X |e 911400PB117795561X |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1865943843 |e 4391033933 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"10 S."}],"recId":"1865943843","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 17.10.2023"],"title":[{"title":"Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT","title_sort":"Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT"}],"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"30 March 2021"}],"person":[{"display":"Brandelik, Simone Christine","role":"aut","given":"Simone Christine","family":"Brandelik"},{"family":"Skornitzke","given":"Stephan","role":"aut","display":"Skornitzke, Stephan"},{"given":"Theresa","role":"aut","family":"Mokry","display":"Mokry, Theresa"},{"display":"Sauer, Sandra","family":"Sauer","role":"aut","given":"Sandra"},{"display":"Stiller, Wolfram","role":"aut","given":"Wolfram","family":"Stiller"},{"display":"Nattenmüller, Johanna","family":"Nattenmüller","role":"aut","given":"Johanna"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"family":"Weber","given":"Tim","role":"aut","display":"Weber, Tim"},{"role":"aut","given":"Thuy","family":"Do","display":"Do, Thuy"}],"relHost":[{"id":{"zdb":["1472718-3"],"eki":["268757526"],"issn":["1432-1084","1613-3757"]},"part":{"text":"31(2021), 10, Seite 7664-7673","extent":"10","issue":"10","pages":"7664-7673","volume":"31","year":"2021"},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"pubHistory":["1.1991 -"],"corporate":[{"role":"isb","display":"European Association of Radiology"}],"disp":"Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CTEuropean radiology","recId":"268757526","physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"official organ of the European Association of Radiology","title_sort":"European radiology","title":"European radiology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"origin":[{"dateIssuedKey":"1991","dateIssuedDisp":"1991-","publisherPlace":"Berlin ; Heidelberg","publisher":"Springer"}]}],"id":{"doi":["10.1007/s00330-021-07821-0"],"eki":["1865943843"]},"name":{"displayForm":["S.C. Brandelik, S. Skornitzke, T. Mokry, S. Sauer, W. Stiller, J. Nattenmüller, H.U. Kauczor, T. F. Weber, T.D. Do"]}} | ||
| SRT | |a BRANDELIKSQUANTITATI3020 | ||