Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams

Background The possible emergence of the FLASH effect—the sparing of normal tissue while maintaining tumor control—after irradiations at dose-rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigatin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tessonnier, Thomas (VerfasserIn) , Verona-Rinati, Gianluca (VerfasserIn) , Rank, Luisa (VerfasserIn) , Kranzer, Rafael (VerfasserIn) , Mairani, Andrea (VerfasserIn) , Marinelli, Marco (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 September 2023
In: Medical physics
Year: 2024, Jahrgang: 51, Heft: 2, Pages: 1450-1459
ISSN:2473-4209
DOI:10.1002/mp.16757
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/mp.16757
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.16757
Volltext
Verfasserangaben:Thomas Tessonnier, Gianluca Verona-Rinati, Luisa Rank, Rafael Kranzer, Andrea Mairani, Marco Marinelli

MARC

LEADER 00000caa a22000002c 4500
001 1870340094
003 DE-627
005 20241209121049.0
007 cr uuu---uuuuu
008 231115s2023 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.16757  |2 doi 
035 |a (DE-627)1870340094 
035 |a (DE-599)KXP1870340094 
035 |a (OCoLC)1425209530 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Tessonnier, Thomas  |e VerfasserIn  |0 (DE-588)1075079195  |0 (DE-627)83292685X  |0 (DE-576)443252270  |4 aut 
245 1 0 |a Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams  |c Thomas Tessonnier, Gianluca Verona-Rinati, Luisa Rank, Rafael Kranzer, Andrea Mairani, Marco Marinelli 
264 1 |c 24 September 2023 
300 |b Illustrationen 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.11.2023 
520 |a Background The possible emergence of the FLASH effect—the sparing of normal tissue while maintaining tumor control—after irradiations at dose-rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigating and reporting the dose and instantaneous dose-rate of ultra-high dose-rate (UHDR) particle radiotherapy beams is crucial for understanding and assessing the FLASH effect, towards pre-clinical application and quality assurance programs. Purpose The purpose of the present work is to investigate a novel diamond-based detector system for dose and instantaneous dose-rate measurements in UHDR particle beams. Methods Two types of diamond detectors, a microDiamond (PTW 60019) and a diamond detector prototype specifically designed for operation in UHDR beams (flashDiamond), and two different readout electronic chains, were investigated for absorbed dose and instantaneous dose-rate measurements. The detectors were irradiated with a helium beam of 145.7 MeV/u under conventional and UHDR delivery. Dose-rate delivery records by the monitoring ionization chamber and diamond detectors were studied for single spot irradiations. Dose linearity at 5 cm depth and in-depth dose response from 2 to 16 cm were investigated for both measurement chains and both detectors in a water tank. Measurements with cylindrical and plane-parallel ionization chambers as well as Monte-Carlo simulations were performed for comparisons. Results Diamond detectors allowed for recording the temporal structure of the beam, in good agreement with the one obtained by the monitoring ionization chamber. A better time resolution of the order of few μs was observed as compared to the approximately 50 μs of the monitoring ionization chamber. Both diamonds detectors show an excellent linearity response in both delivery modalities. Dose values derived by integrating the measured instantaneous dose-rates are in very good agreement with the ones obtained by the standard electrometer readings. Bragg peak curves confirmed the consistency of the charge measurements by the two systems. Conclusions The proposed novel dosimetric system allows for a detailed investigation of the temporal evolution of UHDR beams. As a result, reliable and accurate determinations of dose and instantaneous dose-rate are possible, both required for a comprehensive characterization of UHDR beams and relevant for FLASH effect assessment in clinical treatments. 
650 4 |a diamond detector 
650 4 |a FLASH 
650 4 |a instantateneous dose-rate 
650 4 |a particle therapy 
650 4 |a ultra-high dose-rate 
700 1 |a Verona-Rinati, Gianluca  |e VerfasserIn  |4 aut 
700 1 |a Rank, Luisa  |e VerfasserIn  |0 (DE-588)1316585409  |0 (DE-627)1878497219  |4 aut 
700 1 |a Kranzer, Rafael  |d 1976-  |e VerfasserIn  |0 (DE-588)1228351449  |0 (DE-627)1750112353  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
700 1 |a Marinelli, Marco  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 51(2024), 2, Seite 1450-1459  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams 
773 1 8 |g volume:51  |g year:2024  |g number:2  |g pages:1450-1459  |g extent:10  |a Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams 
856 4 0 |u https://doi.org/10.1002/mp.16757  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.16757  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20231115 
993 |a Article 
994 |a 2023 
998 |g 1116742179  |a Mairani, Andrea  |m 1116742179:Mairani, Andrea  |d 50000  |e 50000PM1116742179  |k 0/50000/  |p 5 
999 |a KXP-PPN1870340094  |e 440761286X 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"24 September 2023","dateIssuedKey":"2023"}],"relHost":[{"recId":"265784867","titleAlt":[{"title":"Medical physics online"}],"id":{"eki":["265784867"],"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"]},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 01.08.2025"],"title":[{"title_sort":"Medical physics","title":"Medical physics"}],"origin":[{"dateIssuedKey":"1974","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","dateIssuedDisp":"1974-","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"pubHistory":["1.1974 -"],"disp":"Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beamsMedical physics","part":{"year":"2024","extent":"10","issue":"2","text":"51(2024), 2, Seite 1450-1459","volume":"51","pages":"1450-1459"},"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]}}],"name":{"displayForm":["Thomas Tessonnier, Gianluca Verona-Rinati, Luisa Rank, Rafael Kranzer, Andrea Mairani, Marco Marinelli"]},"recId":"1870340094","physDesc":[{"extent":"10 S.","noteIll":"Illustrationen"}],"language":["eng"],"id":{"doi":["10.1002/mp.16757"],"eki":["1870340094"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title":"Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams","title_sort":"Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams"}],"person":[{"given":"Thomas","role":"aut","roleDisplay":"VerfasserIn","display":"Tessonnier, Thomas","family":"Tessonnier"},{"role":"aut","given":"Gianluca","roleDisplay":"VerfasserIn","family":"Verona-Rinati","display":"Verona-Rinati, Gianluca"},{"family":"Rank","display":"Rank, Luisa","roleDisplay":"VerfasserIn","given":"Luisa","role":"aut"},{"role":"aut","given":"Rafael","roleDisplay":"VerfasserIn","family":"Kranzer","display":"Kranzer, Rafael"},{"role":"aut","given":"Andrea","roleDisplay":"VerfasserIn","display":"Mairani, Andrea","family":"Mairani"},{"roleDisplay":"VerfasserIn","family":"Marinelli","display":"Marinelli, Marco","given":"Marco","role":"aut"}],"note":["Gesehen am 15.11.2023"]} 
SRT |a TESSONNIERDIAMONDDET2420