Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation

We evaluated intermittent and continuous thermodilution cardiac output data in 12 patients undergoing orthotopic liver transplantation. Measurements were performed at 16 predefined time points between induction of anaesthesia and 3 h after reperfusion of the liver graft. Cardiac output measurements...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Böttiger, Bernd W. (VerfasserIn) , Sinner, Barbara (VerfasserIn) , Motsch, Johann (VerfasserIn) , Bach, Alfons (VerfasserIn) , Bauer, Harald (VerfasserIn) , Martin, Eike (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1997
In: Anaesthesia
Year: 1997, Jahrgang: 52, Heft: 3, Pages: 207-214
ISSN:1365-2044
DOI:10.1111/j.1365-2044.1997.079-az0077.x
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/j.1365-2044.1997.079-az0077.x
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1365-2044.1997.079-az0077.x
Volltext
Verfasserangaben:B. W. Böttiger, B. Sinner, J. Motsch, A. Bach, H. Bauer, E. Martin

MARC

LEADER 00000caa a2200000 c 4500
001 1870729536
003 DE-627
005 20240311145456.0
007 cr uuu---uuuuu
008 231121s1997 xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1365-2044.1997.079-az0077.x  |2 doi 
035 |a (DE-627)1870729536 
035 |a (DE-599)KXP1870729536 
035 |a (OCoLC)1425890699 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Böttiger, Bernd W.  |e VerfasserIn  |0 (DE-588)1103463691  |0 (DE-627)861085744  |0 (DE-576)470582464  |4 aut 
245 1 0 |a Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation  |c B. W. Böttiger, B. Sinner, J. Motsch, A. Bach, H. Bauer, E. Martin 
264 1 |c 1997 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 5. Januar 2004 
500 |a Gesehen am 21.11.2023 
520 |a We evaluated intermittent and continuous thermodilution cardiac output data in 12 patients undergoing orthotopic liver transplantation. Measurements were performed at 16 predefined time points between induction of anaesthesia and 3 h after reperfusion of the liver graft. Cardiac output measurements yielded 192 data pairs (intermittent cardiac output range: 1.8-18.9 l.min−1, continuous cardiac output range: 3.3-20.0 l.min−1). During most of the procedure the correlation between intermittent and continuous cardiac output measurements was significant (r = 0.87, p < 0.0001), accompanied with a bias of −0.240 l.min−1 and a degree of precision of 1.789 l.min−1 (< 10.0 l.min−1: 1.137 l.min−1, ≥10.0 l.min−1: 2.220 l.min−1). However, in the early phases after caval clamping and after reperfusion, accuracy was not acceptable. Only during these phases did the difference between the mean values of pulmonary artery blood temperature and rectal temperature increase (after caval clamping) or decrease (after reperfusion). In conclusion, despite acceptable levels of accuracy and precision between intermittent and continuous cardiac output measurement under stable conditions, both methods showed markedly decreased accuracy and precision in the early phases after caval clamping and after reperfusion, possibly owing to increased thermal noise. 
650 4 |a cardiac output. Measurement techniques 
650 4 |a Heart 
650 4 |a liver transplantation 
650 4 |a thermodilution. Surgery 
700 1 |a Sinner, Barbara  |d 1969-  |e VerfasserIn  |0 (DE-588)120788780  |0 (DE-627)704988844  |0 (DE-576)292385978  |4 aut 
700 1 |a Motsch, Johann  |d 1952-  |e VerfasserIn  |0 (DE-588)1059446626  |0 (DE-627)798468319  |0 (DE-576)415532876  |4 aut 
700 1 |a Bach, Alfons  |d 1955-2002  |e VerfasserIn  |0 (DE-588)1079823514  |0 (DE-627)842186859  |0 (DE-576)172612772  |4 aut 
700 1 |a Bauer, Harald  |e VerfasserIn  |0 (DE-588)110558416X  |0 (DE-627)862704502  |0 (DE-576)473632330  |4 aut 
700 1 |a Martin, Eike  |d 1944-  |e VerfasserIn  |0 (DE-588)172250161  |0 (DE-627)697161390  |0 (DE-576)13311869X  |4 aut 
773 0 8 |i Enthalten in  |t Anaesthesia  |d Oxford [u.a.] : Wiley-Blackwell, 1946  |g 52(1997), 3, Seite 207-214  |h Online-Ressource  |w (DE-627)32042779X  |w (DE-600)2003379-5  |w (DE-576)090954645  |x 1365-2044  |7 nnas  |a Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation 
773 1 8 |g volume:52  |g year:1997  |g number:3  |g pages:207-214  |g extent:8  |a Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation 
856 4 0 |u https://doi.org/10.1111/j.1365-2044.1997.079-az0077.x  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1365-2044.1997.079-az0077.x  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20231121 
994 |a 1997 
998 |g 172250161  |a Martin, Eike  |m 172250161:Martin, Eike  |d 910000  |d 910300  |e 910000PM172250161  |e 910300PM172250161  |k 0/910000/  |k 1/910000/910300/  |p 6  |y j 
998 |g 110558416X  |a Bauer, Harald  |m 110558416X:Bauer, Harald  |d 910000  |d 910300  |e 910000PB110558416X  |e 910300PB110558416X  |k 0/910000/  |k 1/910000/910300/  |p 5 
998 |g 1079823514  |a Bach, Alfons  |m 1079823514:Bach, Alfons  |d 910000  |d 910300  |e 910000PB1079823514  |e 910300PB1079823514  |k 0/910000/  |k 1/910000/910300/  |p 4 
998 |g 1059446626  |a Motsch, Johann  |m 1059446626:Motsch, Johann  |d 910000  |d 910300  |e 910000PM1059446626  |e 910300PM1059446626  |k 0/910000/  |k 1/910000/910300/  |p 3 
998 |g 120788780  |a Sinner, Barbara  |m 120788780:Sinner, Barbara  |d 50000  |e 50000PS120788780  |k 0/50000/  |p 2 
998 |g 1103463691  |a Böttiger, Bernd W.  |m 1103463691:Böttiger, Bernd W.  |d 910000  |d 910300  |e 910000PB1103463691  |e 910300PB1103463691  |k 0/910000/  |k 1/910000/910300/  |p 1  |x j 
999 |a KXP-PPN1870729536  |e 4414671582 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"8 S."}],"person":[{"roleDisplay":"VerfasserIn","given":"Bernd W.","family":"Böttiger","role":"aut","display":"Böttiger, Bernd W."},{"family":"Sinner","given":"Barbara","roleDisplay":"VerfasserIn","display":"Sinner, Barbara","role":"aut"},{"display":"Motsch, Johann","role":"aut","family":"Motsch","given":"Johann","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Bach, Alfons","roleDisplay":"VerfasserIn","family":"Bach","given":"Alfons"},{"roleDisplay":"VerfasserIn","family":"Bauer","given":"Harald","role":"aut","display":"Bauer, Harald"},{"role":"aut","display":"Martin, Eike","roleDisplay":"VerfasserIn","given":"Eike","family":"Martin"}],"title":[{"title":"Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation","title_sort":"Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation"}],"language":["eng"],"origin":[{"dateIssuedKey":"1997","dateIssuedDisp":"1997"}],"relHost":[{"part":{"extent":"8","issue":"3","pages":"207-214","text":"52(1997), 3, Seite 207-214","year":"1997","volume":"52"},"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"doi":["10.1111/(ISSN)1365-2044"],"zdb":["2003379-5"],"eki":["32042779X"],"issn":["1365-2044"]},"note":["Gesehen am 12.02.2021"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"32042779X","language":["eng"],"origin":[{"dateIssuedDisp":"1946-","dateIssuedKey":"1946","publisher":"Wiley-Blackwell ; Blackwell Science","publisherPlace":"Oxford [u.a.] ; Oxford [u.a.]"}],"disp":"Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantationAnaesthesia","pubHistory":["1.1946 -"],"title":[{"title_sort":"Anaesthesia","title":"Anaesthesia","subtitle":"the official journal of the Association of Anaesthesists of Great Britain and Ireland"}]}],"recId":"1870729536","type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1111/j.1365-2044.1997.079-az0077.x"],"eki":["1870729536"]},"name":{"displayForm":["B. W. Böttiger, B. Sinner, J. Motsch, A. Bach, H. Bauer, E. Martin"]},"note":["Elektronische Reproduktion der Druck-Ausgabe 5. Januar 2004","Gesehen am 21.11.2023"]} 
SRT |a BOETTIGERBCONTINUOUS1997