Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer

Long image acquisition times of 60-120 s for cone-beam CT (CBCT) limit the number of patients with lung cancer who can undergo volume image guidance under breathhold. We developed a low-dose dual-energy kilovoltage-megavoltage-cone-beam CT (kVMV-CBCT) based on a clinical treatment unit reducing imag...

Full description

Saved in:
Bibliographic Details
Main Authors: Wertz, Hansjörg (Author) , Stsepankou, Dzmitry (Author) , Blessing, Manuel (Author) , Rossi, Michael (Author) , Knox, Chris (Author) , Brown, Kevin (Author) , Gros, Uwe (Author) , Boda-Heggemann, Judit (Author) , Walter, Cornelia (Author) , Hesser, Jürgen (Author) , Lohr, Frank (Author) , Wenz, Frederik (Author)
Format: Article (Journal)
Language:English
Published: 8 July 2010
In: Physics in medicine and biology
Year: 2010, Volume: 55, Issue: 15, Pages: 4203-4217
ISSN:1361-6560
DOI:10.1088/0031-9155/55/15/001
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/0031-9155/55/15/001
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/0031-9155/55/15/001
Get full text
Author Notes:Hansjoerg Wertz, Dzmitry Stsepankou, Manuel Blessing, Michael Rossi, Chris Knox, Kevin Brown, Uwe Gros, Judit Boda-Heggemann, Cornelia Walter, Juergen Hesser, Frank Lohr and Frederik Wenz

MARC

LEADER 00000caa a2200000 c 4500
001 1871582822
003 DE-627
005 20240311121059.0
007 cr uuu---uuuuu
008 231129s2010 xx |||||o 00| ||eng c
024 7 |a 10.1088/0031-9155/55/15/001  |2 doi 
035 |a (DE-627)1871582822 
035 |a (DE-599)KXP1871582822 
035 |a (OCoLC)1425872832 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wertz, Hansjörg  |d 1976-  |e VerfasserIn  |0 (DE-588)143861247  |0 (DE-627)70462401X  |0 (DE-576)339135778  |4 aut 
245 1 0 |a Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer  |c Hansjoerg Wertz, Dzmitry Stsepankou, Manuel Blessing, Michael Rossi, Chris Knox, Kevin Brown, Uwe Gros, Judit Boda-Heggemann, Cornelia Walter, Juergen Hesser, Frank Lohr and Frederik Wenz 
264 1 |c 8 July 2010 
300 |b Illustrationen 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.11.2023 
520 |a Long image acquisition times of 60-120 s for cone-beam CT (CBCT) limit the number of patients with lung cancer who can undergo volume image guidance under breathhold. We developed a low-dose dual-energy kilovoltage-megavoltage-cone-beam CT (kVMV-CBCT) based on a clinical treatment unit reducing imaging time to ⩽15 s. Simultaneous kVMV-imaging was achieved by dedicated synchronization hardware controlling the output of the linear accelerator (linac) based on detector panel readout signals, preventing imaging artifacts from interference of the linac's MV-irradiation and panel readouts. Optimization was performed to minimize the imaging dose. Single MV-projections, reconstructed MV-CBCT images and images of simultaneous 90° kV- and 90° MV-CBCT (180° kVMV-CBCT) were acquired with different parameters. Image quality and imaging dose were evaluated and compared to kV-imaging. Hardware-based kVMV synchronization resulted in artifact-free projections. A combined 180° kVMV-CBCT scan with a total MV-dose of 5 monitor units was acquired in 15 s and with sufficient image quality. The resolution was 5-6 line pairs cm−1 (Catphan phantom). The combined kVMV-scan dose was equivalent to a kV-radiation scan dose of ∼33 mGy. kVMV-CBCT based on a standard linac is promising and can provide ultra-fast online volume image guidance with low imaging dose and sufficient image quality for fast and accurate patient positioning for patients with lung cancer under breathhold. 
700 1 |a Stsepankou, Dzmitry  |d 1976-  |e VerfasserIn  |0 (DE-588)1020647663  |0 (DE-627)69129125X  |0 (DE-576)361517831  |4 aut 
700 1 |a Blessing, Manuel  |d 1981-  |e VerfasserIn  |0 (DE-588)1026795419  |0 (DE-627)727398385  |0 (DE-576)372120873  |4 aut 
700 1 |a Rossi, Michael  |e VerfasserIn  |4 aut 
700 1 |a Knox, Chris  |e VerfasserIn  |4 aut 
700 1 |a Brown, Kevin  |e VerfasserIn  |4 aut 
700 1 |a Gros, Uwe  |e VerfasserIn  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
700 1 |a Walter, Cornelia  |e VerfasserIn  |4 aut 
700 1 |a Hesser, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1020647353  |0 (DE-627)691291071  |0 (DE-576)361513739  |4 aut 
700 1 |a Lohr, Frank  |e VerfasserIn  |0 (DE-588)1025307194  |0 (DE-627)72201967X  |0 (DE-576)37018694X  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 55(2010), 15, Seite 4203-4217  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer 
773 1 8 |g volume:55  |g year:2010  |g number:15  |g pages:4203-4217  |g extent:15  |a Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer 
856 4 0 |u https://doi.org/10.1088/0031-9155/55/15/001  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/0031-9155/55/15/001  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20231129 
993 |a Article 
994 |a 2010 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |d 60000  |e 60000PW113310390  |e 63000PW113310390  |e 60000PW113310390  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 12  |y j 
998 |g 1025307194  |a Lohr, Frank  |m 1025307194:Lohr, Frank  |d 60000  |d 63000  |e 60000PL1025307194  |e 63000PL1025307194  |k 0/60000/  |k 1/60000/63000/  |p 11 
998 |g 1020647353  |a Hesser, Jürgen  |m 1020647353:Hesser, Jürgen  |d 60000  |d 63000  |d 60000  |e 60000PH1020647353  |e 63000PH1020647353  |e 60000PH1020647353  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 10 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |e 60000PB1029853436  |k 0/60000/  |p 8 
998 |g 1026795419  |a Blessing, Manuel  |m 1026795419:Blessing, Manuel  |d 60000  |d 63000  |d 60000  |e 60000PB1026795419  |e 63000PB1026795419  |e 60000PB1026795419  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 3 
998 |g 1020647663  |a Stsepankou, Dzmitry  |m 1020647663:Stsepankou, Dzmitry  |d 60000  |d 63000  |d 60000  |e 60000PS1020647663  |e 63000PS1020647663  |e 60000PS1020647663  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 2 
998 |g 143861247  |a Wertz, Hansjörg  |m 143861247:Wertz, Hansjörg  |d 60000  |e 60000PW143861247  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1871582822  |e 4421702005 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"8 July 2010","dateIssuedKey":"2010"}],"note":["Gesehen am 29.11.2023"],"title":[{"title_sort":"Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer","title":"Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer"}],"id":{"eki":["1871582822"],"doi":["10.1088/0031-9155/55/15/001"]},"name":{"displayForm":["Hansjoerg Wertz, Dzmitry Stsepankou, Manuel Blessing, Michael Rossi, Chris Knox, Kevin Brown, Uwe Gros, Judit Boda-Heggemann, Cornelia Walter, Juergen Hesser, Frank Lohr and Frederik Wenz"]},"physDesc":[{"noteIll":"Illustrationen","extent":"15 S."}],"recId":"1871582822","relHost":[{"language":["eng"],"part":{"volume":"55","extent":"15","pages":"4203-4217","year":"2010","text":"55(2010), 15, Seite 4203-4217","issue":"15"},"pubHistory":["1.1956 -"],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisherPlace":"Bristol","dateIssuedKey":"1956","publisher":"IOP Publ.","dateIssuedDisp":"1956-"}],"title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"disp":"Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancerPhysics in medicine and biology","type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"269016163","id":{"issn":["1361-6560"],"zdb":["1473501-5"],"eki":["269016163"]}}],"person":[{"given":"Hansjörg","role":"aut","family":"Wertz","display":"Wertz, Hansjörg"},{"display":"Stsepankou, Dzmitry","family":"Stsepankou","role":"aut","given":"Dzmitry"},{"display":"Blessing, Manuel","family":"Blessing","given":"Manuel","role":"aut"},{"role":"aut","given":"Michael","display":"Rossi, Michael","family":"Rossi"},{"role":"aut","given":"Chris","display":"Knox, Chris","family":"Knox"},{"role":"aut","given":"Kevin","display":"Brown, Kevin","family":"Brown"},{"display":"Gros, Uwe","family":"Gros","given":"Uwe","role":"aut"},{"family":"Boda-Heggemann","display":"Boda-Heggemann, Judit","role":"aut","given":"Judit"},{"role":"aut","given":"Cornelia","family":"Walter","display":"Walter, Cornelia"},{"given":"Jürgen","role":"aut","display":"Hesser, Jürgen","family":"Hesser"},{"role":"aut","given":"Frank","family":"Lohr","display":"Lohr, Frank"},{"display":"Wenz, Frederik","family":"Wenz","given":"Frederik","role":"aut"}],"language":["eng"]} 
SRT |a WERTZHANSJFASTKILOVO8201