Concepts for the data flow control on the XIDer readout ASIC
XIDer is a 2D pixelated hybrid X-ray detector that is supposed to act as a multi-purpose platform for diffraction experiments at fourth-generation high-energy synchrotron light sources like the Extremely Brilliant Source of the European Synchrotron Radiation Facility (ESRF-EBS). As such it needs to...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
December 2023
|
| In: |
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2023, Volume: 1057, Pages: 1-7 |
| ISSN: | 1872-9576 |
| DOI: | 10.1016/j.nima.2023.168720 |
| Online Access: | Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.nima.2023.168720 Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0168900223007118 |
| Author Notes: | D. Schimansky, P. Busca, M. Collonge, P. Fajardo, P. Fischer, M. Ritzert, M. Williams |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1871585872 | ||
| 003 | DE-627 | ||
| 005 | 20240307035720.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 231129s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.nima.2023.168720 |2 doi | |
| 035 | |a (DE-627)1871585872 | ||
| 035 | |a (DE-599)KXP1871585872 | ||
| 035 | |a (OCoLC)1425209131 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Schimansky, David |d 1992- |e VerfasserIn |0 (DE-588)121050782X |0 (DE-627)1698538944 |4 aut | |
| 245 | 1 | 0 | |a Concepts for the data flow control on the XIDer readout ASIC |c D. Schimansky, P. Busca, M. Collonge, P. Fajardo, P. Fischer, M. Ritzert, M. Williams |
| 264 | 1 | |c December 2023 | |
| 300 | |b Illustrationen | ||
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online verfügbar: 30. September 2023, Artikelversion: 7. Oktober 2023 | ||
| 500 | |a Gesehen am 29.11.2023 | ||
| 520 | |a XIDer is a 2D pixelated hybrid X-ray detector that is supposed to act as a multi-purpose platform for diffraction experiments at fourth-generation high-energy synchrotron light sources like the Extremely Brilliant Source of the European Synchrotron Radiation Facility (ESRF-EBS). As such it needs to tackle a wide variety of requirements. These include x-ray energies of 30keV to 100keV imposing the utilisation of high-Z sensors, a wide dynamic range from single photons to fluxes of 1 × 109photonspixel−1s−1 and expected raw data rates up to the order of TBs−1 in the final detector design. As a result, XIDer’s readout ASIC has to provide smart and flexible ways for on-chip data pre-processing to reduce the output data rate to manageable sizes. This article focusses on introducing the ASIC’s novel and unique data-handling concepts like the custom-designed telegram protocol followed by the presentation of exemplary configurations and use cases. | ||
| 650 | 4 | |a Electronic detector readout concepts | |
| 650 | 4 | |a Front-end electronics for detector readout | |
| 650 | 4 | |a Instrumentation for synchrotrons | |
| 650 | 4 | |a Mixed-mode electronic circuits | |
| 650 | 4 | |a X-ray diffraction detectors | |
| 700 | 1 | |a Busca, P. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Collonge, M. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Fajardo, P. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Fischer, Paulina |d 1987- |e VerfasserIn |0 (DE-588)1131652533 |0 (DE-627)886286670 |0 (DE-576)488349559 |4 aut | |
| 700 | 1 | |a Ritzert, Michael |e VerfasserIn |0 (DE-588)1054166102 |0 (DE-627)791117987 |0 (DE-576)41004783X |4 aut | |
| 700 | 1 | |a Williams, M. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |d [Amsterdam] : Elsevier, 1984 |g 1057(2023) vom: Dez., Artikel-ID 168720, Seite 1-7 |h Online-Ressource |w (DE-627)266014666 |w (DE-600)1466532-3 |w (DE-576)074959743 |x 1872-9576 |7 nnas |a Concepts for the data flow control on the XIDer readout ASIC |
| 773 | 1 | 8 | |g volume:1057 |g year:2023 |g month:12 |g elocationid:168720 |g pages:1-7 |g extent:7 |a Concepts for the data flow control on the XIDer readout ASIC |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.nima.2023.168720 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0168900223007118 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20231129 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 1054166102 |a Ritzert, Michael |m 1054166102:Ritzert, Michael |d 700000 |d 720000 |e 700000PR1054166102 |e 720000PR1054166102 |k 0/700000/ |k 1/700000/720000/ |p 6 | ||
| 998 | |g 1131652533 |a Fischer, Paulina |m 1131652533:Fischer, Paulina |d 700000 |d 711000 |e 700000PF1131652533 |e 711000PF1131652533 |k 0/700000/ |k 1/700000/711000/ |p 5 | ||
| 998 | |g 121050782X |a Schimansky, David |m 121050782X:Schimansky, David |d 700000 |d 720000 |e 700000PS121050782X |e 720000PS121050782X |k 0/700000/ |k 1/700000/720000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1871585872 |e 4421709123 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1871585872","relHost":[{"note":["Gesehen am 24.05.23"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"part":{"volume":"1057","extent":"7","year":"2023","pages":"1-7","text":"1057(2023) vom: Dez., Artikel-ID 168720, Seite 1-7"},"id":{"issn":["1872-9576"],"eki":["266014666"],"zdb":["1466532-3"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"pubHistory":["Nachgewiesen 226.1984 -"],"recId":"266014666","title":[{"title_sort":"Nuclear instruments & methods in physics research","title":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","partname":"Accelerators, spectrometers, detectors and associated equipment"}],"disp":"Concepts for the data flow control on the XIDer readout ASICNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"1994-","publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994","publisher":"Elsevier ; North-Holland Publ. Co."}]}],"title":[{"title":"Concepts for the data flow control on the XIDer readout ASIC","title_sort":"Concepts for the data flow control on the XIDer readout ASIC"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}],"origin":[{"dateIssuedDisp":"December 2023","dateIssuedKey":"2023"}],"note":["Online verfügbar: 30. September 2023, Artikelversion: 7. Oktober 2023","Gesehen am 29.11.2023"],"name":{"displayForm":["D. Schimansky, P. Busca, M. Collonge, P. Fajardo, P. Fischer, M. Ritzert, M. Williams"]},"id":{"eki":["1871585872"],"doi":["10.1016/j.nima.2023.168720"]},"person":[{"given":"David","role":"aut","roleDisplay":"VerfasserIn","display":"Schimansky, David","family":"Schimansky"},{"given":"P.","roleDisplay":"VerfasserIn","role":"aut","display":"Busca, P.","family":"Busca"},{"family":"Collonge","roleDisplay":"VerfasserIn","role":"aut","display":"Collonge, M.","given":"M."},{"family":"Fajardo","given":"P.","role":"aut","roleDisplay":"VerfasserIn","display":"Fajardo, P."},{"family":"Fischer","display":"Fischer, Paulina","roleDisplay":"VerfasserIn","role":"aut","given":"Paulina"},{"family":"Ritzert","display":"Ritzert, Michael","roleDisplay":"VerfasserIn","role":"aut","given":"Michael"},{"family":"Williams","role":"aut","roleDisplay":"VerfasserIn","display":"Williams, M.","given":"M."}]} | ||
| SRT | |a SCHIMANSKYCONCEPTSFO2023 | ||