Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors

Purpose: - To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL. - Setting: - The David J. Apple Center for Vision Research,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Khoramnia, Ramin (VerfasserIn) , Baur, Isabella (VerfasserIn) , Łabuz, Grzegorz (VerfasserIn) , Chychko, Lizaveta (VerfasserIn) , Köppe, Maximilian (VerfasserIn) , Hallak, Mustafa (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: February 2023
In: Journal of cataract and refractive surgery
Year: 2023, Jahrgang: 49, Heft: 2, Pages: 1-6
ISSN:1873-4502
DOI:10.1097/j.jcrs.0000000000001064
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/j.jcrs.0000000000001064
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/fulltext/2023/02000/enlargement_of_main_corneal_incision__clinical.10.aspx
Volltext
Verfasserangaben:Ramin Khoramnia, MD, PhD, FEBO, Isabella D. Baur, MD, Grzegorz Łabuz, PhD, Lizaveta Chychko, Maximilian K. Köppe, MD, Mustafa K. Hallak, MD, Gerd U. Auffarth, MD, PhD, FEBO

MARC

LEADER 00000caa a2200000 c 4500
001 1875843973
003 DE-627
005 20240331080403.0
007 cr uuu---uuuuu
008 231214s2023 xx |||||o 00| ||eng c
024 7 |a 10.1097/j.jcrs.0000000000001064  |2 doi 
035 |a (DE-627)1875843973 
035 |a (DE-599)KXP1875843973 
035 |a (OCoLC)1425208281 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
245 1 0 |a Enlargement of main corneal incision  |b clinical intraindividual comparison of two preloaded intraocular lens injectors  |c Ramin Khoramnia, MD, PhD, FEBO, Isabella D. Baur, MD, Grzegorz Łabuz, PhD, Lizaveta Chychko, Maximilian K. Köppe, MD, Mustafa K. Hallak, MD, Gerd U. Auffarth, MD, PhD, FEBO 
264 1 |c February 2023 
300 |b Illustrationen 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 14.12.2023 
520 |a Purpose: - To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL. - Setting: - The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. - Design: - Prospective randomized clinical comparative study. - Methods: - 96 eyes of 48 patients with cataract were intraindividually randomized to treatment with 1 of the 2 injectors. For Multisert eyes, the insert shield (IS) was used in the advanced position in 23 eyes. The initial incision was 2.2 mm, and intraoperative measurements of the incision size were made before and after IOL injection. 3 months postoperatively, keratometry and uncorrected (UDVA) and corrected (CDVA) distance visual acuities were assessed. - Results: - Results are reported for 96 eyes of 48 patients. The mean incision enlargement was 0.213 ± 0.068 mm in the Multisert with the IS group, 0.265 ± 0.055 mm in the fellow eyes (AutonoMe) (P < .05), 0.272 ± 0.060 mm in Multisert eyes treated without the IS, and 0.296 ± 0.066 mm for the fellow eyes (AutonoMe) (P > .05). The mean absolute surgically induced astigmatism was 0.42 ± 0.23 diopters (D), 0.50 ± 0.25 D, and 0.44 ± 0.18 D in the Multisert with the IS, Multisert without the IS, and AutonoMe group, respectively (P > .05). The UDVA and CDVA were comparable in all groups. - Conclusions: - The Multisert was associated with less wound enlargement than the AutonoMe. All groups had comparable functional outcomes. Therefore, the observed difference in incision enlargement may be of limited clinical relevance. 
700 1 |a Baur, Isabella  |e VerfasserIn  |0 (DE-588)1196639396  |0 (DE-627)1678468975  |4 aut 
700 1 |a Łabuz, Grzegorz  |e VerfasserIn  |0 (DE-588)1185406743  |0 (DE-627)1664595244  |4 aut 
700 1 |a Chychko, Lizaveta  |e VerfasserIn  |0 (DE-588)1313481165  |0 (DE-627)1875890769  |4 aut 
700 1 |a Köppe, Maximilian  |d 1994-  |e VerfasserIn  |0 (DE-588)1277170223  |0 (DE-627)1830314955  |4 aut 
700 1 |a Hallak, Mustafa  |e VerfasserIn  |0 (DE-588)1284331733  |0 (DE-627)1840070617  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 49(2023), 2 vom: Feb., Artikel-ID 165, Seite 1-6  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Enlargement of main corneal incision clinical intraindividual comparison of two preloaded intraocular lens injectors 
773 1 8 |g volume:49  |g year:2023  |g number:2  |g month:02  |g elocationid:165  |g pages:1-6  |g extent:6  |a Enlargement of main corneal incision clinical intraindividual comparison of two preloaded intraocular lens injectors 
856 4 0 |u https://doi.org/10.1097/j.jcrs.0000000000001064  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jcrs/fulltext/2023/02000/enlargement_of_main_corneal_incision__clinical.10.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20231214 
993 |a Article 
994 |a 2023 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 7  |y j 
998 |g 1284331733  |a Hallak, Mustafa K.  |m 1284331733:Hallak, Mustafa K.  |d 910000  |d 910900  |e 910000PH1284331733  |e 910900PH1284331733  |k 0/910000/  |k 1/910000/910900/  |p 6 
998 |g 1277170223  |a Köppe, Maximilian  |m 1277170223:Köppe, Maximilian  |d 910000  |d 910900  |e 910000PK1277170223  |e 910900PK1277170223  |k 0/910000/  |k 1/910000/910900/  |p 5 
998 |g 1313481165  |a Chychko, Lizaveta  |m 1313481165:Chychko, Lizaveta  |d 910000  |d 910900  |e 910000PC1313481165  |e 910900PC1313481165  |k 0/910000/  |k 1/910000/910900/  |p 4 
998 |g 1185406743  |a Łabuz, Grzegorz  |m 1185406743:Łabuz, Grzegorz  |d 910000  |d 910900  |e 910000PŁ1185406743  |e 910900PŁ1185406743  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 1196639396  |a Baur, Isabella  |m 1196639396:Baur, Isabella  |d 910000  |d 910900  |e 910000PB1196639396  |e 910900PB1196639396  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |d 50000  |e 910000PK132573954  |e 910900PK132573954  |e 50000PK132573954  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1875843973  |e 4437302109 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Enlargement of main corneal incision","title":"Enlargement of main corneal incision","subtitle":"clinical intraindividual comparison of two preloaded intraocular lens injectors"}],"name":{"displayForm":["Ramin Khoramnia, MD, PhD, FEBO, Isabella D. Baur, MD, Grzegorz Łabuz, PhD, Lizaveta Chychko, Maximilian K. Köppe, MD, Mustafa K. Hallak, MD, Gerd U. Auffarth, MD, PhD, FEBO"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"February 2023"}],"person":[{"display":"Khoramnia, Ramin","role":"aut","family":"Khoramnia","given":"Ramin"},{"role":"aut","display":"Baur, Isabella","family":"Baur","given":"Isabella"},{"given":"Grzegorz","display":"Łabuz, Grzegorz","role":"aut","family":"Łabuz"},{"display":"Chychko, Lizaveta","role":"aut","family":"Chychko","given":"Lizaveta"},{"given":"Maximilian","display":"Köppe, Maximilian","role":"aut","family":"Köppe"},{"given":"Mustafa","role":"aut","display":"Hallak, Mustafa","family":"Hallak"},{"display":"Auffarth, Gerd U.","role":"aut","family":"Auffarth","given":"Gerd U."}],"id":{"eki":["1875843973"],"doi":["10.1097/j.jcrs.0000000000001064"]},"note":["Gesehen am 14.12.2023"],"language":["eng"],"physDesc":[{"noteIll":"Illustrationen","extent":"6 S."}],"recId":"1875843973","relHost":[{"title":[{"title_sort":"Journal of cataract and refractive surgery","title":"Journal of cataract and refractive surgery"}],"disp":"Enlargement of main corneal incision clinical intraindividual comparison of two preloaded intraocular lens injectorsJournal of cataract and refractive surgery","name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"eki":["320594203"],"issn":["1873-4502"],"zdb":["2019330-0"]},"part":{"issue":"2","volume":"49","extent":"6","text":"49(2023), 2 vom: Feb., Artikel-ID 165, Seite 1-6","year":"2023","pages":"1-6"},"origin":[{"dateIssuedDisp":"2020-","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","dateIssuedKey":"2020","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]"}],"pubHistory":["12.1986 -"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"note":["Gesehen am 02.08.24"],"recId":"320594203","physDesc":[{"extent":"Online-Ressource"}]}]} 