Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses
PURPOSE: - - To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
October 01, 2023
|
| In: |
Journal of refractive surgery
Year: 2023, Jahrgang: 39, Heft: 10, Pages: 668-674 |
| ISSN: | 1938-2391 |
| DOI: | 10.3928/1081597X-20230831-01 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3928/1081597X-20230831-01 Verlag, lizenzpflichtig, Volltext: https://journals.healio.com/doi/10.3928/1081597X-20230831-01 |
| Verfasserangaben: | Isabella D. Baur, MD, Weijia Yan, MD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD, PhD, and Grzegorz Łabuz, PhD |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1876820047 | ||
| 003 | DE-627 | ||
| 005 | 20240307032120.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 231221s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3928/1081597X-20230831-01 |2 doi | |
| 035 | |a (DE-627)1876820047 | ||
| 035 | |a (DE-599)KXP1876820047 | ||
| 035 | |a (OCoLC)1425208063 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Baur, Isabella |e VerfasserIn |0 (DE-588)1196639396 |0 (DE-627)1678468975 |4 aut | |
| 245 | 1 | 0 | |a Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses |c Isabella D. Baur, MD, Weijia Yan, MD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD, PhD, and Grzegorz Łabuz, PhD |
| 264 | 1 | |c October 01, 2023 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 21.12.2023 | ||
| 520 | |a PURPOSE: - - To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc). - - METHODS: - - An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps. Area under the MTF and simulated visual acuity were calculated for different pupil diameters. Wavefront aberrations were measured with the SHS Ophthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor. - - RESULTS: - - All EDOF lenses yielded a simulated far visual acuity of 0.00 logMAR (20/20 Snellen) or better. At the 0.20 logMAR visual acuity level, the EDOF IOLs showed an increased depth of focus of at least 0.75 diopters compared to the monofocal IOL. Pupil dependency was more pronounced with the MiniWell, LuxSmart, and Vivity, whereas the Lentis showed a more consistent behavior at different apertures. The wavefront measurement revealed increased central aberrations for the MiniWell, LuxSmart, and Vivity IOL compared to the monofocal control. - - CONCLUSIONS: - - All EDOF IOLs demonstrated increased depth of focus while maintaining good simulated visual acuity at the far focus. Pupil dependency differed between the IOL models. The wavefront analysis revealed the complex design of the different EDOF IOLs with several zones with varying aberrations. - - [J Refract Surg. 2023;39(10):668-674.] | ||
| 700 | 1 | |a Yan, Weijia |d 1994- |e VerfasserIn |0 (DE-588)1274781213 |0 (DE-627)1824544235 |4 aut | |
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 700 | 1 | |a Khoramnia, Ramin |d 1980- |e VerfasserIn |0 (DE-588)132573954 |0 (DE-627)523957173 |0 (DE-576)299234355 |4 aut | |
| 700 | 1 | |a Łabuz, Grzegorz |e VerfasserIn |0 (DE-588)1185406743 |0 (DE-627)1664595244 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of refractive surgery |d Thorofare, NJ : SLACK Inc., 1996 |g 39(2023), 10, Seite 668-674 |h Online-Ressource |w (DE-627)333811267 |w (DE-600)2056758-3 |w (DE-576)433787627 |x 1938-2391 |7 nnas |a Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses |
| 773 | 1 | 8 | |g volume:39 |g year:2023 |g number:10 |g pages:668-674 |g extent:7 |a Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses |
| 856 | 4 | 0 | |u https://doi.org/10.3928/1081597X-20230831-01 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.healio.com/doi/10.3928/1081597X-20230831-01 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20231221 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 1185406743 |a Łabuz, Grzegorz |m 1185406743:Łabuz, Grzegorz |d 910000 |d 910900 |e 910000PŁ1185406743 |e 910900PŁ1185406743 |k 0/910000/ |k 1/910000/910900/ |p 5 |y j | ||
| 998 | |g 132573954 |a Khoramnia, Ramin |m 132573954:Khoramnia, Ramin |d 910000 |d 910900 |d 50000 |e 910000PK132573954 |e 910900PK132573954 |e 50000PK132573954 |k 0/910000/ |k 1/910000/910900/ |k 0/50000/ |p 4 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1274781213 |a Yan, Weijia |m 1274781213:Yan, Weijia |d 50000 |e 50000PY1274781213 |k 0/50000/ |p 2 | ||
| 998 | |g 1196639396 |a Baur, Isabella |m 1196639396:Baur, Isabella |d 50000 |e 50000PB1196639396 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1876820047 |e 4442735034 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"note":["Gesehen am 21.12.2023"],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"333811267","note":["Gesehen am 26.09.24"],"part":{"volume":"39","extent":"7","issue":"10","pages":"668-674","text":"39(2023), 10, Seite 668-674","year":"2023"},"id":{"zdb":["2056758-3"],"eki":["333811267"],"issn":["1938-2391"]},"origin":[{"publisher":"SLACK Inc.","publisherPlace":"Thorofare, NJ","dateIssuedKey":"1996","dateIssuedDisp":"1996-"}],"disp":"Optical quality and higher order aberrations of refractive extended depth of focus intraocular lensesJournal of refractive surgery","title":[{"subtitle":"the official publication of the International Society of Refractive Surgery","title_sort":"Journal of refractive surgery","title":"Journal of refractive surgery"}],"language":["eng"],"pubHistory":["Nachgewiesen 12.1996 -"]}],"physDesc":[{"extent":"7 S."}],"recId":"1876820047","name":{"displayForm":["Isabella D. Baur, MD, Weijia Yan, MD, Gerd U. Auffarth, MD, PhD, Ramin Khoramnia, MD, PhD, and Grzegorz Łabuz, PhD"]},"title":[{"title":"Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses","title_sort":"Optical quality and higher order aberrations of refractive extended depth of focus intraocular lenses"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.3928/1081597X-20230831-01"],"eki":["1876820047"]},"person":[{"display":"Baur, Isabella","role":"aut","family":"Baur","given":"Isabella"},{"given":"Weijia","role":"aut","display":"Yan, Weijia","family":"Yan"},{"given":"Gerd U.","family":"Auffarth","display":"Auffarth, Gerd U.","role":"aut"},{"role":"aut","display":"Khoramnia, Ramin","family":"Khoramnia","given":"Ramin"},{"given":"Grzegorz","display":"Łabuz, Grzegorz","role":"aut","family":"Łabuz"}],"origin":[{"dateIssuedDisp":"October 01, 2023","dateIssuedKey":"2023"}]} | ||
| SRT | |a BAURISABELOPTICALQUA0120 | ||