Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE
Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition...
Saved in:
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
January 2024
|
| In: |
Magnetic resonance imaging
Year: 2024, Volume: 105, Pages: 75-81 |
| ISSN: | 1873-5894 |
| DOI: | 10.1016/j.mri.2023.11.004 |
| Online Access: | Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.mri.2023.11.004 Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X2300190X |
| Author Notes: | Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1878991159 | ||
| 003 | DE-627 | ||
| 005 | 20240331080437.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240125s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.mri.2023.11.004 |2 doi | |
| 035 | |a (DE-627)1878991159 | ||
| 035 | |a (DE-599)KXP1878991159 | ||
| 035 | |a (OCoLC)1425200323 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Zhang, Ke |d 1984- |e VerfasserIn |0 (DE-588)142064564 |0 (DE-627)704133199 |0 (DE-576)327160438 |4 aut | |
| 245 | 1 | 0 | |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE |c Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek |
| 246 | 3 | 3 | |a Simultaneous T 1, T 2 and T 2 * mapping of the liver with multi-shot MI-SAGE |
| 264 | 1 | |c January 2024 | |
| 300 | |b Illustrationen | ||
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Im Titel sind die Zahlen tiefgestellt | ||
| 500 | |a Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023 | ||
| 500 | |a Gesehen am 25.01.2024 | ||
| 520 | |a Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences. - Results - The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation. - Conclusions - The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan. | ||
| 650 | 4 | |a Liver | |
| 650 | 4 | |a Multi inversion spin and gradient echo | |
| 650 | 4 | |a Multi-shot acquisitions | |
| 650 | 4 | |a Parametric mapping | |
| 700 | 1 | |a Triphan, Simon M. F. |e VerfasserIn |0 (DE-588)1072565080 |0 (DE-627)827729553 |0 (DE-576)434034207 |4 aut | |
| 700 | 1 | |a Wielpütz, Mark Oliver |d 1982- |e VerfasserIn |0 (DE-588)139999752 |0 (DE-627)614754682 |0 (DE-576)314127046 |4 aut | |
| 700 | 1 | |a Ziener, Christian H. |d 1978- |e VerfasserIn |0 (DE-588)137982755 |0 (DE-627)59885309X |0 (DE-576)306117355 |4 aut | |
| 700 | 1 | |a Ladd, Mark E. |e VerfasserIn |0 (DE-588)108120964X |0 (DE-627)845690507 |0 (DE-576)454039999 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Kurz, Felix T. |d 1981- |e VerfasserIn |0 (DE-588)1043285474 |0 (DE-627)771321066 |0 (DE-576)394610342 |4 aut | |
| 700 | 1 | |a Sedlaczek, Oliver |d 1970- |e VerfasserIn |0 (DE-588)123144493 |0 (DE-627)706179838 |0 (DE-576)293576173 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Magnetic resonance imaging |d Amsterdam [u.a.] : Elsevier Science, 1982 |g 105(2024) vom: Jan., Seite 75-81 |h Online-Ressource |w (DE-627)306661160 |w (DE-600)1500646-3 |w (DE-576)081986750 |x 1873-5894 |7 nnas |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE |
| 773 | 1 | 8 | |g volume:105 |g year:2024 |g month:01 |g pages:75-81 |g extent:7 |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.mri.2023.11.004 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0730725X2300190X |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240125 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 123144493 |a Sedlaczek, Oliver |m 123144493:Sedlaczek, Oliver |d 910000 |d 911400 |e 910000PS123144493 |e 911400PS123144493 |k 0/910000/ |k 1/910000/911400/ |p 9 |y j | ||
| 998 | |g 1043285474 |a Kurz, Felix T. |m 1043285474:Kurz, Felix T. |d 50000 |e 50000PK1043285474 |k 0/50000/ |p 8 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 6 | ||
| 998 | |g 108120964X |a Ladd, Mark E. |m 108120964X:Ladd, Mark E. |d 130000 |e 130000PL108120964X |k 0/130000/ |p 5 | ||
| 998 | |g 137982755 |a Ziener, Christian H. |m 137982755:Ziener, Christian H. |d 50000 |e 50000PZ137982755 |k 0/50000/ |p 4 | ||
| 998 | |g 139999752 |a Wielpütz, Mark Oliver |m 139999752:Wielpütz, Mark Oliver |d 910000 |d 911400 |d 50000 |e 910000PW139999752 |e 911400PW139999752 |e 50000PW139999752 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 3 | ||
| 998 | |g 1072565080 |a Triphan, Simon M. F. |m 1072565080:Triphan, Simon M. F. |d 910000 |d 911400 |e 910000PT1072565080 |e 911400PT1072565080 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 142064564 |a Zhang, Ke |m 142064564:Zhang, Ke |d 910000 |d 911400 |e 910000PZ142064564 |e 911400PZ142064564 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1878991159 |e 4467788247 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE","title_sort":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE"}],"person":[{"display":"Zhang, Ke","given":"Ke","role":"aut","family":"Zhang"},{"given":"Simon M. F.","display":"Triphan, Simon M. F.","role":"aut","family":"Triphan"},{"display":"Wielpütz, Mark Oliver","given":"Mark Oliver","role":"aut","family":"Wielpütz"},{"display":"Ziener, Christian H.","given":"Christian H.","role":"aut","family":"Ziener"},{"family":"Ladd","role":"aut","display":"Ladd, Mark E.","given":"Mark E."},{"family":"Schlemmer","role":"aut","given":"Heinz-Peter","display":"Schlemmer, Heinz-Peter"},{"role":"aut","display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","family":"Kauczor"},{"family":"Kurz","role":"aut","given":"Felix T.","display":"Kurz, Felix T."},{"display":"Sedlaczek, Oliver","given":"Oliver","role":"aut","family":"Sedlaczek"}],"physDesc":[{"noteIll":"Illustrationen","extent":"7 S."}],"titleAlt":[{"title":"Simultaneous T 1, T 2 and T 2 * mapping of the liver with multi-shot MI-SAGE"}],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGEMagnetic resonance imaging","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Magnetic resonance imaging","subtitle":"an international journal of basic research and clinical applications","title":"Magnetic resonance imaging"}],"part":{"text":"105(2024) vom: Jan., Seite 75-81","pages":"75-81","year":"2024","extent":"7","volume":"105"},"language":["eng"],"id":{"issn":["1873-5894"],"zdb":["1500646-3"],"eki":["306661160"]},"pubHistory":["1.1982 -"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1982","dateIssuedDisp":"1982-","publisher":"Elsevier Science"}],"note":["Gesehen am 29.01.2020"],"recId":"306661160"}],"name":{"displayForm":["Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek"]},"language":["eng"],"id":{"eki":["1878991159"],"doi":["10.1016/j.mri.2023.11.004"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"January 2024"}],"note":["Im Titel sind die Zahlen tiefgestellt","Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023","Gesehen am 25.01.2024"],"recId":"1878991159"} | ||
| SRT | |a ZHANGKETRISIMULTANEO2024 | ||