Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE

Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, Ke (Author) , Triphan, Simon M. F. (Author) , Wielpütz, Mark Oliver (Author) , Ziener, Christian H. (Author) , Ladd, Mark E. (Author) , Schlemmer, Heinz-Peter (Author) , Kauczor, Hans-Ulrich (Author) , Kurz, Felix T. (Author) , Sedlaczek, Oliver (Author)
Format: Article (Journal)
Language:English
Published: January 2024
In: Magnetic resonance imaging
Year: 2024, Volume: 105, Pages: 75-81
ISSN:1873-5894
DOI:10.1016/j.mri.2023.11.004
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.mri.2023.11.004
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X2300190X
Get full text
Author Notes:Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek

MARC

LEADER 00000caa a2200000 c 4500
001 1878991159
003 DE-627
005 20240331080437.0
007 cr uuu---uuuuu
008 240125s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.mri.2023.11.004  |2 doi 
035 |a (DE-627)1878991159 
035 |a (DE-599)KXP1878991159 
035 |a (OCoLC)1425200323 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zhang, Ke  |d 1984-  |e VerfasserIn  |0 (DE-588)142064564  |0 (DE-627)704133199  |0 (DE-576)327160438  |4 aut 
245 1 0 |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE  |c Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek 
246 3 3 |a Simultaneous T 1, T 2 and T 2 * mapping of the liver with multi-shot MI-SAGE 
264 1 |c January 2024 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Im Titel sind die Zahlen tiefgestellt 
500 |a Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023 
500 |a Gesehen am 25.01.2024 
520 |a Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences. - Results - The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation. - Conclusions - The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan. 
650 4 |a Liver 
650 4 |a Multi inversion spin and gradient echo 
650 4 |a Multi-shot acquisitions 
650 4 |a Parametric mapping 
700 1 |a Triphan, Simon M. F.  |e VerfasserIn  |0 (DE-588)1072565080  |0 (DE-627)827729553  |0 (DE-576)434034207  |4 aut 
700 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
700 1 |a Ziener, Christian H.  |d 1978-  |e VerfasserIn  |0 (DE-588)137982755  |0 (DE-627)59885309X  |0 (DE-576)306117355  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Kurz, Felix T.  |d 1981-  |e VerfasserIn  |0 (DE-588)1043285474  |0 (DE-627)771321066  |0 (DE-576)394610342  |4 aut 
700 1 |a Sedlaczek, Oliver  |d 1970-  |e VerfasserIn  |0 (DE-588)123144493  |0 (DE-627)706179838  |0 (DE-576)293576173  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance imaging  |d Amsterdam [u.a.] : Elsevier Science, 1982  |g 105(2024) vom: Jan., Seite 75-81  |h Online-Ressource  |w (DE-627)306661160  |w (DE-600)1500646-3  |w (DE-576)081986750  |x 1873-5894  |7 nnas  |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE 
773 1 8 |g volume:105  |g year:2024  |g month:01  |g pages:75-81  |g extent:7  |a Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE 
856 4 0 |u https://doi.org/10.1016/j.mri.2023.11.004  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0730725X2300190X  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240125 
993 |a Article 
994 |a 2024 
998 |g 123144493  |a Sedlaczek, Oliver  |m 123144493:Sedlaczek, Oliver  |d 910000  |d 911400  |e 910000PS123144493  |e 911400PS123144493  |k 0/910000/  |k 1/910000/911400/  |p 9  |y j 
998 |g 1043285474  |a Kurz, Felix T.  |m 1043285474:Kurz, Felix T.  |d 50000  |e 50000PK1043285474  |k 0/50000/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 6 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |e 130000PL108120964X  |k 0/130000/  |p 5 
998 |g 137982755  |a Ziener, Christian H.  |m 137982755:Ziener, Christian H.  |d 50000  |e 50000PZ137982755  |k 0/50000/  |p 4 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 910000  |d 911400  |d 50000  |e 910000PW139999752  |e 911400PW139999752  |e 50000PW139999752  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 3 
998 |g 1072565080  |a Triphan, Simon M. F.  |m 1072565080:Triphan, Simon M. F.  |d 910000  |d 911400  |e 910000PT1072565080  |e 911400PT1072565080  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 142064564  |a Zhang, Ke  |m 142064564:Zhang, Ke  |d 910000  |d 911400  |e 910000PZ142064564  |e 911400PZ142064564  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1878991159  |e 4467788247 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE","title_sort":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE"}],"person":[{"display":"Zhang, Ke","given":"Ke","role":"aut","family":"Zhang"},{"given":"Simon M. F.","display":"Triphan, Simon M. F.","role":"aut","family":"Triphan"},{"display":"Wielpütz, Mark Oliver","given":"Mark Oliver","role":"aut","family":"Wielpütz"},{"display":"Ziener, Christian H.","given":"Christian H.","role":"aut","family":"Ziener"},{"family":"Ladd","role":"aut","display":"Ladd, Mark E.","given":"Mark E."},{"family":"Schlemmer","role":"aut","given":"Heinz-Peter","display":"Schlemmer, Heinz-Peter"},{"role":"aut","display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","family":"Kauczor"},{"family":"Kurz","role":"aut","given":"Felix T.","display":"Kurz, Felix T."},{"display":"Sedlaczek, Oliver","given":"Oliver","role":"aut","family":"Sedlaczek"}],"physDesc":[{"noteIll":"Illustrationen","extent":"7 S."}],"titleAlt":[{"title":"Simultaneous T 1, T 2 and T 2 * mapping of the liver with multi-shot MI-SAGE"}],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGEMagnetic resonance imaging","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Magnetic resonance imaging","subtitle":"an international journal of basic research and clinical applications","title":"Magnetic resonance imaging"}],"part":{"text":"105(2024) vom: Jan., Seite 75-81","pages":"75-81","year":"2024","extent":"7","volume":"105"},"language":["eng"],"id":{"issn":["1873-5894"],"zdb":["1500646-3"],"eki":["306661160"]},"pubHistory":["1.1982 -"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1982","dateIssuedDisp":"1982-","publisher":"Elsevier Science"}],"note":["Gesehen am 29.01.2020"],"recId":"306661160"}],"name":{"displayForm":["Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek"]},"language":["eng"],"id":{"eki":["1878991159"],"doi":["10.1016/j.mri.2023.11.004"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"January 2024"}],"note":["Im Titel sind die Zahlen tiefgestellt","Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023","Gesehen am 25.01.2024"],"recId":"1878991159"} 
SRT |a ZHANGKETRISIMULTANEO2024