Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures

Objectives: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading confi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bömicke, Wolfgang (VerfasserIn) , Boisserée, Philipp (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Rues, Stefan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 15 January 2024
In: Clinical oral investigations
Year: 2024, Jahrgang: 28, Pages: 1-14
ISSN:1436-3771
DOI:10.1007/s00784-024-05501-z
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00784-024-05501-z
Volltext
Verfasserangaben:Wolfgang Bömicke, Philipp Boisserée, Peter Rammelsberg, Stefan Rues

MARC

LEADER 00000caa a2200000 c 4500
001 1881320545
003 DE-627
005 20240307020250.0
007 cr uuu---uuuuu
008 240221s2024 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00784-024-05501-z  |2 doi 
035 |a (DE-627)1881320545 
035 |a (DE-599)KXP1881320545 
035 |a (OCoLC)1425200204 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
245 1 0 |a Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures  |c Wolfgang Bömicke, Philipp Boisserée, Peter Rammelsberg, Stefan Rues 
264 1 |c 15 January 2024 
300 |b Illustrationen 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.02.2024 
520 |a Objectives: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. Materials and methods: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. Results: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. Conclusions: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. Clinical relevance: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided. 
650 4 |a Fracture load 
650 4 |a Implant fixed dental prosthesis 
650 4 |a Load-bearing capacity 
650 4 |a Monolithic zirconia 
650 4 |a Translucent zirconia 
650 4 |a Zirconium dioxide 
700 1 |a Boisserée, Philipp  |e VerfasserIn  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
773 0 8 |i Enthalten in  |t Clinical oral investigations  |d Berlin : Springer, 1997  |g 28(2024), Artikel-ID 94, Seite 1-14  |h Online-Ressource  |w (DE-627)268756139  |w (DE-600)1472578-2  |w (DE-576)09448029X  |x 1436-3771  |7 nnas  |a Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures 
773 1 8 |g volume:28  |g year:2024  |g elocationid:94  |g pages:1-14  |g extent:14  |a Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures 
856 4 0 |u https://doi.org/10.1007/s00784-024-05501-z  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240221 
993 |a Article 
994 |a 2024 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 4  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |d 50000  |e 910000PB1015022146  |e 910800PB1015022146  |e 50000PB1015022146  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1881320545  |e 4489199872 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures","title_sort":"Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures"}],"person":[{"given":"Wolfgang","display":"Bömicke, Wolfgang","family":"Bömicke","role":"aut"},{"role":"aut","display":"Boisserée, Philipp","family":"Boisserée","given":"Philipp"},{"given":"Peter","family":"Rammelsberg","display":"Rammelsberg, Peter","role":"aut"},{"role":"aut","display":"Rues, Stefan","family":"Rues","given":"Stefan"}],"physDesc":[{"noteIll":"Illustrationen","extent":"14 S."}],"relHost":[{"title":[{"title_sort":"Clinical oral investigations","subtitle":"Organ of: Deutsche Gesellschaft für Zahn-, Mund- und Kieferheilkunde","title":"Clinical oral investigations"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"pages":"1-14","text":"28(2024), Artikel-ID 94, Seite 1-14","volume":"28","year":"2024","extent":"14"},"origin":[{"publisher":"Springer","dateIssuedKey":"1997","publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1997-"}],"language":["eng"],"id":{"eki":["268756139"],"zdb":["1472578-2"],"issn":["1436-3771"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"268756139","pubHistory":["1.1997 -"],"note":["Gesehen am 27.10.04"],"disp":"Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial denturesClinical oral investigations"}],"language":["eng"],"id":{"doi":["10.1007/s00784-024-05501-z"],"eki":["1881320545"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"15 January 2024"}],"name":{"displayForm":["Wolfgang Bömicke, Philipp Boisserée, Peter Rammelsberg, Stefan Rues"]},"note":["Gesehen am 21.02.2024"],"recId":"1881320545"} 
SRT |a BOEMICKEWOINITIALDAM1520