Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort

Purpose - To determine the predictors of Bruch membrane opening (BMO) location accuracy and the visibility of the BMO location in glaucoma and healthy individuals with and without axial high myopia. - Design - Cross-sectional study. - Methods - Healthy eyes and eyes with glaucoma from an American st...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rezapour, Jasmin (VerfasserIn) , Proudfoot, James A. (VerfasserIn) , Bowd, Christopher (VerfasserIn) , Dohleman, Jade (VerfasserIn) , Christopher, Mark (VerfasserIn) , Belghith, Akram (VerfasserIn) , Vega, Suzanne M. (VerfasserIn) , Dirkes, Keri (VerfasserIn) , Suh, Min Hee (VerfasserIn) , Jonas, Jost B. (VerfasserIn) , Hyman, Leslie (VerfasserIn) , Fazio, Massimo A. (VerfasserIn) , Sella, Ruti (VerfasserIn) , Afshari, Natalie A. (VerfasserIn) , Weinreb, Robert N. (VerfasserIn) , Zangwill, Linda M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 2022
In: American journal of ophthalmology
Year: 2022, Jahrgang: 237, Pages: 221-234
ISSN:1879-1891
DOI:10.1016/j.ajo.2021.11.030
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ajo.2021.11.030
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0002939421006322
Volltext
Verfasserangaben:Jasmin Rezapour, James A. Proudfoot, Christopher Bowd, Jade Dohleman, Mark Christopher, Akram Belghith, Suzanne M. Vega, Keri Dirkes, Min Hee Suh, Jost B. Jonas, Leslie Hyman, Massimo A. Fazio, Ruti Sella, Natalie A. Afshari, Robert N. Weinreb, and Linda M. Zangwill

MARC

LEADER 00000caa a2200000 c 4500
001 1882476573
003 DE-627
005 20240325174231.0
007 cr uuu---uuuuu
008 240305s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ajo.2021.11.030  |2 doi 
035 |a (DE-627)1882476573 
035 |a (DE-599)KXP1882476573 
035 |a (OCoLC)1425215335 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rezapour, Jasmin  |d 1988-  |e VerfasserIn  |0 (DE-588)1074554957  |0 (DE-627)832289752  |0 (DE-576)442742959  |4 aut 
245 1 0 |a Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort  |c Jasmin Rezapour, James A. Proudfoot, Christopher Bowd, Jade Dohleman, Mark Christopher, Akram Belghith, Suzanne M. Vega, Keri Dirkes, Min Hee Suh, Jost B. Jonas, Leslie Hyman, Massimo A. Fazio, Ruti Sella, Natalie A. Afshari, Robert N. Weinreb, and Linda M. Zangwill 
264 1 |c May 2022 
300 |b Illustrationen 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 10. Dezember 2021, Artikelversion: 28. Januar 2022 
500 |a Gesehen am 05.03.2024 
520 |a Purpose - To determine the predictors of Bruch membrane opening (BMO) location accuracy and the visibility of the BMO location in glaucoma and healthy individuals with and without axial high myopia. - Design - Cross-sectional study. - Methods - Healthy eyes and eyes with glaucoma from an American study and a Korean clinic population were classified into 2 groups: those with no axial high myopia (axial length [AL] <26 mm) and those with axial high myopia (AL ≥26 mm). The accuracy of the automated BMO location on optic nerve head Spectralis optical coherence tomography radial scans was assessed by expert reviewers. - Results - Four hundred thirty-eight non-highly myopic eyes (263 subjects) and 113 highly myopic eyes (81 subjects) were included. In healthy eyes with and without axial high myopia, 9.1% and 1.7% had indiscernible BMOs while 54.5% and 87.6% were accurately segmented, respectively. More than a third (36.4%) and 10.7% of eyes with indiscernible BMOs were manually correctable (respectively, P = .017). In eyes with glaucoma with and without high myopia, 15.0% and 3.2% had indiscernible BMOs, 55.0% and 38.2% were manually corrected, and 30.0% and 58.7% were accurately segmented without the need for manual correction (respectively, P = .005). Having axial high myopia, a larger AL, a larger BMO tilt angle, a lower BMO ovality index (more oval), and a glaucoma diagnosis were significant predictors of BMO location inaccuracy in multivariable logistic regression analysis. - Conclusions - As BMO location inaccuracy was 2.4 times more likely in eyes with high axial myopia regardless of diagnosis, optical coherence tomography images of high myopes should be reviewed carefully, and when possible, BMO location should be corrected before using optic nerve head scan results for the clinical management of glaucoma. 
700 1 |a Proudfoot, James A.  |e VerfasserIn  |4 aut 
700 1 |a Bowd, Christopher  |e VerfasserIn  |4 aut 
700 1 |a Dohleman, Jade  |e VerfasserIn  |4 aut 
700 1 |a Christopher, Mark  |e VerfasserIn  |4 aut 
700 1 |a Belghith, Akram  |e VerfasserIn  |4 aut 
700 1 |a Vega, Suzanne M.  |e VerfasserIn  |4 aut 
700 1 |a Dirkes, Keri  |e VerfasserIn  |4 aut 
700 1 |a Suh, Min Hee  |e VerfasserIn  |4 aut 
700 1 |a Jonas, Jost B.  |d 1958-  |e VerfasserIn  |0 (DE-588)1028286732  |0 (DE-627)730536823  |0 (DE-576)37578537X  |4 aut 
700 1 |a Hyman, Leslie  |e VerfasserIn  |4 aut 
700 1 |a Fazio, Massimo A.  |e VerfasserIn  |4 aut 
700 1 |a Sella, Ruti  |e VerfasserIn  |4 aut 
700 1 |a Afshari, Natalie A.  |e VerfasserIn  |4 aut 
700 1 |a Weinreb, Robert N.  |e VerfasserIn  |4 aut 
700 1 |a Zangwill, Linda M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t American journal of ophthalmology  |d New York, NY : Elsevier Science, 1918  |g 237(2022) vom: Mai, Seite 221-234  |h Online-Ressource  |w (DE-627)320596281  |w (DE-600)2019600-3  |w (DE-576)121466353  |x 1879-1891  |7 nnas  |a Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort 
773 1 8 |g volume:237  |g year:2022  |g month:05  |g pages:221-234  |g extent:14  |a Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort 
856 4 0 |u https://doi.org/10.1016/j.ajo.2021.11.030  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0002939421006322  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240305 
993 |a Article 
994 |a 2022 
998 |g 1028286732  |a Jonas, Jost B.  |m 1028286732:Jonas, Jost B.  |d 60000  |e 60000PJ1028286732  |k 0/60000/  |p 10 
999 |a KXP-PPN1882476573  |e 4495711733 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort","title":"Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohort"}],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"May 2022"}],"note":["Online veröffentlicht: 10. Dezember 2021, Artikelversion: 28. Januar 2022","Gesehen am 05.03.2024"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"14 S.","noteIll":"Illustrationen"}],"name":{"displayForm":["Jasmin Rezapour, James A. Proudfoot, Christopher Bowd, Jade Dohleman, Mark Christopher, Akram Belghith, Suzanne M. Vega, Keri Dirkes, Min Hee Suh, Jost B. Jonas, Leslie Hyman, Massimo A. Fazio, Ruti Sella, Natalie A. Afshari, Robert N. Weinreb, and Linda M. Zangwill"]},"relHost":[{"part":{"year":"2022","pages":"221-234","extent":"14","text":"237(2022) vom: Mai, Seite 221-234","volume":"237"},"titleAlt":[{"title":"AJO"}],"language":["eng"],"id":{"issn":["1879-1891"],"zdb":["2019600-3"],"eki":["320596281"]},"recId":"320596281","physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Frank W. Newell, ed.-in-chief [u.a.]"]},"disp":"Bruch membrane opening detection accuracy in healthy eyes and eyes with glaucoma with and without axial high myopia in an American and Korean cohortAmerican journal of ophthalmology","type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title_sort":"American journal of ophthalmology","subtitle":"AJO","title":"American journal of ophthalmology"}],"origin":[{"publisherPlace":"New York, NY","dateIssuedDisp":"1918-","publisher":"Elsevier Science","dateIssuedKey":"1918"}],"note":["Gesehen am 21.09.2020","Ungezählte Beil.: Supplement"],"pubHistory":["Nachgewiesen 3.Ser. 1.1918 -"]}],"recId":"1882476573","id":{"eki":["1882476573"],"doi":["10.1016/j.ajo.2021.11.030"]},"person":[{"role":"aut","given":"Jasmin","display":"Rezapour, Jasmin","family":"Rezapour"},{"family":"Proudfoot","display":"Proudfoot, James A.","given":"James A.","role":"aut"},{"display":"Bowd, Christopher","family":"Bowd","given":"Christopher","role":"aut"},{"family":"Dohleman","display":"Dohleman, Jade","role":"aut","given":"Jade"},{"given":"Mark","role":"aut","family":"Christopher","display":"Christopher, Mark"},{"family":"Belghith","display":"Belghith, Akram","given":"Akram","role":"aut"},{"family":"Vega","display":"Vega, Suzanne M.","role":"aut","given":"Suzanne M."},{"given":"Keri","role":"aut","family":"Dirkes","display":"Dirkes, Keri"},{"given":"Min Hee","role":"aut","family":"Suh","display":"Suh, Min Hee"},{"given":"Jost B.","role":"aut","family":"Jonas","display":"Jonas, Jost B."},{"family":"Hyman","display":"Hyman, Leslie","role":"aut","given":"Leslie"},{"family":"Fazio","display":"Fazio, Massimo A.","role":"aut","given":"Massimo A."},{"given":"Ruti","role":"aut","family":"Sella","display":"Sella, Ruti"},{"given":"Natalie A.","role":"aut","display":"Afshari, Natalie A.","family":"Afshari"},{"family":"Weinreb","display":"Weinreb, Robert N.","role":"aut","given":"Robert N."},{"family":"Zangwill","display":"Zangwill, Linda M.","role":"aut","given":"Linda M."}],"language":["eng"]} 
SRT |a REZAPOURJABRUCHMEMBR2022